Typical Scan Tool Data
WARNING: This page is about a different variant/trim than selected.
ECT Sensor
| Circuit |
Short to Ground |
Open |
Short to Voltage |
Operating Conditions:
Engine Running at various operating conditions Parameter Normal Range:
Varies with coolant temperature |
| ECT Sensor Signal |
150°C (302°F) |
-40°C (-40°F) |
-40°C (-40°F) |
| Low Reference |
- |
-40°C (-40°F) |
-40°C (-40°F) |