Installation Procedure
NOTE:
Use care when handling the coolant sensor. Damage to the coolant sensor will affect the operation of the fuel control system.
- If installing the old sensor(s), coat the threads with sealant GM P/N 12346004 (Canadian P/N 10953480), or equivalent.
- Install the appropriate ECT sensor(s) (1).
Tighten: Tighten the sensor(s) to 20 N.m (15 lb ft).
- Connect the engine wiring harness electrical connector(s) (1) to the appropriate ECT sensor(s).
- Fill the cooling system, if necessary. Refer to Draining and Filling Cooling System (Static Fill) or Draining and Filling Cooling System (Vac N Fill) .
- Install the intake manifold tube. Refer to Intake Manifold Tube Replacement (LLY, LBZ) or Intake Manifold Tube Replacement (LMM) .
NOTE:
Refer to Fastener Notice
.