Circuit/System Description
The control module has 2 internal 5-volt reference busses called 5-volt reference 1 and 5-volt reference 2. Each reference bus provides 5-volt reference circuits for more than one sensor. Therefore, a fault condition on one 5-volt reference circuit will affect the other 5-volt reference circuits connected to that reference bus. The control module monitors the voltage on the 5-volt reference busses.
The 5-volt reference 1 bus provides 5 volts to the following sensors:
- The fuel tank pressure (FTP) sensor
- The exhaust gas recirculation (EGR) valve
The 5-volt reference 2 bus provides 5 volts to the following sensors:
- The manifold absolute pressure (MAP) sensor
- The air conditioning (A/C) refrigerant pressure sensor