Removal Procedure
- If equipped with a power sliding door, disable the PSD system by removing the PSD 15A fuse from the instrument panel (I/P) fuse block.
- Remove the sliding door garnish molding. Refer to Garnish Molding Replacement - Sliding Door in Interior Trim.
- Use a small flat-bladed tool in order to remove the plugs from the swing-out window access hole on the sliding door.
- Remove the swing-out window latch screws.
- Remove the stud nuts from the swing-out window hinge.
- Remove the swing-out window from the sliding door.
IMPORTANT: