Circuit/System Testing
- If any other indicators are inoperative on the instrument panel (IP) cluster, refer to Symptoms - Instrument Panel, Gages and Console in Instrument Panel, Gages, and Console.
- Ignition OFF, disconnect the ECM harness connector.
- Ignition ON, the MIL should not illuminate.
- If the MIL illuminates, test the MIL control circuit for a short to ground. If the circuit test normal, replace the instrument panel (IP) cluster.
- Ignition ON, connect a 3-amp fused jumper wire between the MIL control circuit and ground. The MIL should illuminate.
- If the MIL does not illuminate, test the MIL control circuit for a short to voltage or an open/high resistance. If the circuit test normal, replace the instrument panel (IP) cluster.
- If the MIL illuminates, inspect for a poor connection or replace the ECM.