Circuit/System Testing
- Reconnect all previously disconnected EVAP hardware.
- Ignition OFF. Connect the J 41413-200 power supply clips to a known good 12-volt source. See Special Tools .
- Remove the fuel tank filler cap. Install the GE-41415-50 to the fuel fill pipe.
- Install the fuel tank filler cap to the GE-41415-50 .
- Ignition ON, engine OFF, with a scan tool, seal the EVAP system.
- Turn the nitrogen/smoke valve on the EEST to nitrogen.
- Use the remote switch to activate the J 41413-200 and pressurize the fuel tank with nitrogen to 5 in H20. See Special Tools .
- While observing the FTP sensor parameter with a scan tool, command the EVAP vent valve OFF.
- Verify the FTP Sensor parameter is 0 in H2O.
- If not check for a blockage or restrictions in the EVAP vent hose, or replace the EVAP vent solenoid valve.
IMPORTANT:
DO NOT exceed the specified value in this step. Exceeding the specified value may produce incorrect test results.