Typical Scan Tool Data
Cylinder Deactivation Data
| Circuit | Normal Range | Short to Ground | Open | Short to Voltage |
|---|---|---|---|---|
| Operating Conditions: Engine running, vehicle traveling at 40 MPH, under a light load condition, and steady throttle input | ||||
| Cylinder Deactivation System Command | V4 or V8 mode | V8 mode | V8 mode | V8 mode |
| Cylinder 1, 4, 6, 7, Deactivation Solenoid Command | ON or OFF | OFF | OFF | OFF |
| Cylinder 1, 4, 6, 7, Deactivation Solenoid Circuit Status | Incomplete or OK | Short to GRD/Open | Short to GRD/Open | Short to B+ |
| Cylinder Deactivation Performance | OK | Fault | Fault | Fault |