Test Description
The numbers below refer to the step numbers on the diagnostic table.
- 2: A partial loss or intermittent loss of communication in the class 2 serial data circuit uses a different procedure than a total loss of communication of the class 2 serial data circuit.
- 10: If there are no current DTCs that begin with the letter "U", the communication concern has been repaired.
- 11: The communication concern may have prevented diagnosis of the customer complaint.
Scan Tool Does Not Communicate with Class 2 Device
| Step | Action | Yes | No |
|---|---|---|---|
| Schematic Reference: Data Link Connector (DLC) Schematics Connector End View Reference: Master Electrical Component List . |
|||
| 1 | Does the scan tool power up? | Go to Step 2 | Go to Scan Tool Does Not Power Up |
| 2 |
|
Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 |
| 3 |
|
Go to Step 9 | Go to Step 4 |
| 4 |
IMPORTANT:
Turn ON the ignition, with the engine OFF, when testing for a short to voltage. Use the DMM MIN/MAX function to capture intermittent conditions. Test the class 2 serial data circuit for a short to ground or a short to voltage. Refer to Circuit Testing
.Did you find and correct the condition? |
Go to Step 9 | Go to Step 5 |
| 5 |
|
Go to Step 9 | Go to Step 6 |
| 6 | Test the signal ground circuits of the DLC for an open or high resistance. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
. Did you find and correct the condition? |
Go to Step 9 | Go to Step 7 |
| 7 | Inspect for poor connections and terminal tension at the harness connector of the PCM. Refer to Testing for Intermittent Conditions and Poor Connections
and Wiring Repairs
. Did you find and correct the condition? |
Go to Step 9 | Go to Step 8 |
| 8 |
IMPORTANT:
Perform the module setup procedure if required. Refer to Control Module References . Replace the suspect module. Refer to Control Module References for the appropriate Repair Instructions for module replacement.Did you complete the replacement? |
Go to Step 9 | - |
| 9 |
IMPORTANT:
The scan tool may require a power up reset before communication will occur due to a short on the class 2 serial data circuit. Turn OFF or disconnect the scan tool before you display DTCs.
|
Go to Step 11 | Go to Step 10 |
| 10 | Did you record any DTCs which do not begin with a letter "U"? | Go to Step 11 | Go to Step 13 |
| 11 | Diagnose the DTCs as directed by the diagnostic procedures for the particular concern. Did you complete the action? |
Go to Step 12 | - |
| 12 | Did you diagnose all of the DTCs? | Go to Step 13 | Go to Step 11 |
| 13 | Clear the DTCs using the scan tool. Did you complete the action? |
System OK | - |