Typical Scan Tool Data
MAP Sensor
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
Engine operating in Closed Loop. Parameter Normal Range: 32-40 kPa, 1.15-1.3 V |
|||
| 5-Volt Reference | 50 kPa, 0.0 V | 50 kPa, 0.0 V | 121 kPa, 4.93 V |
| MAP Sensor Signal | 50 kPa, 0.0 V | 50 kPa, 0.0 V | 121 kPa, 5.0 V |
| Low Reference | - | 121 kPa, 4.45 V | 121 kPa, 5.0 V1 |
| 1 Internal ECM damage may occur if the circuit is shorted to B+. | |||