Typical Scan Tool Data
IAT 2 Temperature Sensor
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
Key ON, engine OFF Normal Range varies between: -39 to +120°C (-38 to +248°F) |
|||
| IAT 2 Sensor Signal | 150°C (300°F) | -40°C (-40°F) | -40°C (-40°F) |
| Low Reference | - | -40°C (-40°F) | -40°C (-40°F) |
IAT Sensor
| Circuit | Short to Ground | Open or High Resistance | Short to Voltage |
|---|---|---|---|
| Normal range varies between: -39 to +120°C (-38 to +248°F) | |||
| IAT Sensor Signal | 140°C (284°F) | -40°C (-40°F) | -40°C (-40°F) |
| IAT Low Reference | - | -40°C (-40°F) | -40°C (-40°F) |