Circuit/System Testing
- Disconnect the ECT sensor.
- Turn ON the ignition, with the engine OFF.
- Measure for the proper voltage range of 4.9-5.2 volts between the ECT signal circuit and a good ground with a DMM.
- If the voltage is less than 4.9 volts, test the ECT sensor signal circuit for a high resistance short to ground or a faulty ECM.
- Remove and test the ECT sensor. Refer to Component Testing.
- If the resistance measurements of the ECT sensor are out of range, replace the sensor.
- If the ECT sensor tests normal and the DTC continues to set, replace the ECM.