Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Chevrolet >> 2004 >> SSR >> Repair and Diagnosis >> External Pages >> Different car >> Section 683 (Folding Top System) >> Diagnostic Information and Procedures >> Scan Tool Output Controls

Scan Tool Output Controls

WARNING: This page is about a different car, the 2003 Chevrolet SSR. However, it is still accessible from the selected car via links, so may be relevant.
Roof and Door Module (RDM) Scan Tool Output Controls

Scan Tool Output Control Additional Menu Selection(s) Description
Header Latch - The roof/door module (RDM) actuates the header latch to the Latched position when commanded ON. The header latch will actuate to Unlatched when commanded OFF.
Pump Motor Direction - When the Open command is selected, the roof/door module (RDM) will actuate the hydraulic pump motor in the roof open rotational direction for 2 seconds.
When the Close command is selected, the RDM will actuate the hydraulic pump motor in both directions. First in the roof close rotational direction for 2 seconds, then pausing for 3 additional seconds and then activating the pump in the open direction for 2 more seconds.
Roof System - The roof/door module (RDM) operates the roof system through a complete open cycle when commanded Open. When Close is commanded, the RDM operates the roof system through a complete close cycle. The roof Open and Close cycle commands can be terminated at any time by pressing the Exit or Abort key.
Tonneau Latch - The roof/door module (RDM) actuates the tonneau latch to the unlatched position when commanded Off. The RDM actuates the tonneau latch to the latched position when commanded On.
Valve 1 - When commanded On, the roof/door module (RDM) energizes the #1 hydraulic pump solenoid valve to the open position for 5 seconds or until commanded Off. In a partially closed roof situation, the roof panels will retract to their mechanical resting position while the valve is open.
Valve 2 - When commanded On, the roof/door module (RDM) energizes the #2 hydraulic pump solenoid valve to the open position for 5 seconds or until commanded Off. In a partially closed roof situation, the roof panels will retract to their mechanical resting position while the valve is open.
Valve 3 - When commanded On, the roof/door module (RDM) energizes the #3 hydraulic pump solenoid valve to the open position for 5 seconds or until commanded Off. In a partially closed roof situation, the roof panels will retract to their mechanical resting position while the valve is open.
Valve 4 - When commanded On, the roof/door module (RDM) energizes the #4 hydraulic pump solenoid valve to the open position for 5 seconds or until commanded Off. In a partially closed roof situation, the roof panels will retract to their mechanical resting position while the valve is open.