Circuit Description
HO2S-1 produces a voltage that varies between 100-900 millivolts under normal operating conditions. PCM monitors this voltage and determines if exhaust is lean or rich. If voltage input at PCM is about 100 millivolts, exhaust is lean. If voltage input at PCM is about 900 millivolts, exhaust is rich. PCM constantly monitors HO2S-1 signal during closed loop operation and compensates for a lean or rich condition by adjusting injector pulse width as necessary.
DTC will set when engine is at idle and at normal operating temperature, HO2S-1 maximum voltage average is greater than .40 volt, or minimum voltage average is less than .55 volt.
When DTC sets, MIL will illuminate after 2 consecutive ignition cycles in which diagnostic runs with active fault. PCM will record operating conditions at time of failure and store information in freeze frame buffer.