Diagnostic Procedure
- Test the battery positive voltage circuit of the DLC for an open or a short to ground. If there is no fault, go to next step. If there is any fault, repair and recheck system operation.
- Test the ground circuit at DLC terminal No. 4 for an open. If there is no fault, go to next step. If there is any fault, repair and recheck system operation.
- Inspect for poor connections at DLC terminals No. 4 and 16. If there is no fault, go to next step. If there is any fault, repair and recheck system operation.
- The scan tool may be malfunctioning. Refer to the scan tool user guide.