Possible Causes & Corrections
- Ensure Torque Converter Clutch (TCC) is not stuck on.
- Check brakelight switch operation.
- Check PCV valve for proper operation.
- Check for plugged or restricted fuel lines.
- If engine starts but then immediately stalls, open distributor by-pass circuit. If engine now starts and runs okay, replace distributor pick-up coil.
- Using Spark Tester (J-26792), check for a weak spark from ignition coil.
- Check Idle Air Control (IAC) system for proper operation.
- Unplug MAP sensor. PCM substitutes a default value for sensor signal. If stall condition is eliminated, replace MAP sensor.
- Check EGR system for proper operation.
- If stall occurs when air conditioner is turned on, check for air conditioner clutch signal to PCM terminal. Voltage at A/C terminal of PCM should be battery voltage when air conditioner compressor clutch is engaged. A high voltage surge due to a shorted compressor clutch diode could cause PCM shutdown.
- Check for an overcharged A/C system.