Right Power Mirror Does Not Operate In Up/Down Positions
- Disconnect power mirror switch connector. Connect test light between power mirror switch terminals "E" (Orange wire) and "B" (Brown/White wire). With right mirror selected, move power mirror switch to up position. If test light illuminates, go to next step. If test light does not illuminate, replace power mirror switch.
- Connect test light between power mirror switch terminals "D" (Black wire) and "C" (Light Blue/White wire). Move power mirror switch to up position. If test light illuminates, go to next step. If test light does not illuminate, replace power mirror switch.
- Connect test light between power mirror switch terminals "D" (Black wire) and "B" (Brown/White wire). Move power mirror switch to down position. If test light illuminates, go to next step. If test light does not illuminate, replace power mirror switch.
- Connect test light between power mirror switch terminals "E" (Orange wire) and "C" (Light Blue/White wire). Move power mirror switch to down position. If test light illuminates, go to next step. If test light does not illuminate, replace power mirror switch.
- Disconnect right power mirror connector. Connect test light between power mirror switch harness connector terminal "B" (Brown/White wire) and right power mirror harness connector terminal "D" (Brown/White wire). If test light illuminates, go to next step. If test light does not illuminate, repair open in Brown/White wire between power mirror switch and right power mirror.
- Connect test light between power mirror switch harness connector terminal "C" (Light Blue/White wire) and right power mirror harness connector terminal "E" (Light Blue/White wire). If test light illuminates, replace right power mirror. If test light does not illuminate, repair open in Light Blue/White wire between power mirror switch and right power mirror.