Rear Window Release - Power: Operation
Rear window release system has voltage at all times through 25-amp T/G REL fuse. Ground is provided through Parking Brake Warning switch (man. trans.) of park/neutral position switch (auto. trans.). Switches are closed to ground when transmission is in Park or Neutral, or when parking brake is set. Operating release switch allows current to flow to release solenoid, which completes circuit to ground, releasing window latch.