AH Models: Replacement
- Disconnect battery ground cable and discharge system. Disconnect inlet and outlet lines, then cop all open fittings and lines. Remove accumulator mounting screws and accumulator.
- Measure amount of refrigerant oil in accumulator. Fill new accumulator with same amount plus 2 oz. of new refrigerant oil. Use new "O" rings lubricated with oil when installing fittings.