Temperature Versus Resistance - Drive Unit Fluid Temperature Sensor
| Temperature | Resistance |
|---|---|
| 150°C (302°F) | 55 to 60 ohms |
| 145°C (293°F) | 62 to 66 ohms |
| 140°C (284°F) | 69 to 74 ohms |
| 135°C (275°F) | 77 to 82 ohms |
| 130°C (266°F) | 86 to 92 ohms |
| 125°C (257°F) | 97 to 103 ohms |
| 120°C (248°F) | 110 to 116 ohms |
| 115°C (239°F) | 124 to 131 ohms |
| 110°C (230°F) | 141 to 148 ohms |
| 105°C (221°F) | 160 to 167 ohms |
| 100°C (212°F) | 183 to 190 ohms |
| 95°C (203°F) | 208 to 217 ohms |
| 90°C (194°F) | 237 to 249 ohms |
| 85°C (185°F) | 272 to 287 ohms |
| 80°C (176°F) | 313 to 332 ohms |
| 75°C (167°F) | 363 to 386 ohms |
| 70°C (158°F) | 421 to 450 ohms |
| 65°C (149°F) | 490 to 526 ohms |
| 60°C (140°F) | 573 to 618 ohms |
| 55°C (131°F) | 675 to 731 ohms |
| 50°C (122°F) | 798 to 869 ohms |
| 45°C (113°F) | 943 to 1032 ohms |
| 40°C (104°F) | 1118 to 1230 ohms |
| 35°C (95°F) | 1339 to 1483 ohms |
| 30°C (86°F) | 1615 to 1797 ohms |
| 25°C (77°F) | 1940 to 2172 ohms |
| 20°C (68°F) | 2350 to 2648 ohms |
| 15°C (59°F) | 2876 to 3260 ohms |
| 10°C (50°F) | 3541 to 4041 ohms |
| 5°C (41°F) | 4384 to 5038 ohms |
| 0°C (32°F) | 5465 to 6325 ohms |
| -5°C (23°F) | 6846 to 7980 ohms |
| -10°C (14°F) | 8640 to 10150 ohms |
| -15°C (5°F) | 10989 to 13011 ohms |
| -20°C (-4°F) | 14092 to 16824 ohms |
| -25°C (-13°F) | 18147 to 21851 ohms |
| -30°C (-22°F) | 23575 to 28641 ohms |
| -35°C (-31°F) | 30790 to 37756 ohms |
| -40°C (-40°F) | 40481 to 50125 ohms |