Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Cadillac >> 2019 >> XTS Base >> Repair and Diagnosis >> External Pages >> Different car >> Section 63 (Heating System, Ventilation System, And Air Conditioning System) >> Specifications >> Approximate Fluid Capacities

Approximate Fluid Capacities

WARNING: This page is about a different car, the 2018 Cadillac XTS. However, it is still accessible from the selected car via links, so may be relevant.
Refrigerant System Capacities

Application Specification
Metric English
Abrupt Refrigerant Loss (With V4U) 60 ml1 2.0 oz1
Abrupt Refrigerant Loss (Without V4U) 45 ml1 1.5 oz1
Compressor Replacement
NOTE:

Compressor failure can occur if the oil removed during refrigerant recovery is not replaced.

The service compressor is precharged with the following amount of PAG oil. Refer to the instruction sheet included with the service compressor.
40 ml2 1.4 oz2
Condenser Replacement (With V4U) 60 ml2 2.0 oz2
Condenser Replacement (Without V4U) 45 ml2 1.5 oz2
Evaporator Replacement (With V4U) 60 ml2 2.0 oz2
Evaporator Replacement (Without V4U) 45 ml2 1.5 oz2
Any Line Set (Hose/Tube or Tube Assembly) Replacement (With V4U) 30 ml2 1.0 oz2
Any Line Set (Hose/Tube or Tube Assembly) Replacement (Without V4U) 23 ml2 0.8 oz2
Total System PAG Oil Capacity (With V4U) 200.0 ml 6.8 oz
Total System PAG Oil Capacity (Without V4U) 150.0 ml 5.1 oz
R-134a (Without KRV)
  • Refrigerant Charge
0.68 kg 1.50 lb
R-1234yf (With KRV)
  • Refrigerant Charge
0.60 kg 1.30 lb
1 Abrupt refrigerant loss due to large leak, hose rupture, collision, or pressure relief valve opening. Conditions that allow the refrigerant to seep or bleed off over time do not cause this oil loss. Upon replacement of a component that caused a large refrigerant loss, also add the required amount of oil for the particular component.
2 If more than the specified amount of PAG oil was drained from a component, add the amount drained.