Conditions for Setting the DTC
DTC P0D4D
The difference between the battery charger DC output voltage and hybrid/EV battery DC input voltage is greater than 30 V.
DTC P0D4E
The battery charger DC output duty cycle is between 1% and 8%.
OR
The battery charger DC output duty cycle equals 100%.
DTC P0D4F
The battery charger DC output duty cycle is between 92% and 99%.
OR
The battery charger DC output duty cycle equals 0%.