Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Cadillac >> 2015 >> SRX Base, 4D Utility >> Repair and Diagnosis >> Body & Frame >> Body, Cab Control Systems >> Power Door Lock System And Release Systems >> Repair Instructions >> Liftgate Hydraulic System Bleeding

Liftgate Hydraulic System Bleeding

WARNING:

Refer to Eye Protection Warning .

NOTE:

Inspection of the hydraulic fluid level and/or refilling may only be completed if the liftgate hydraulic actuator pump is removed from the vehicle and placed on a clean/level workbench horizontally to the + sign to accurately inspect and add fluid as needed. The liftgate hydraulic actuator pump must rest in the horizontal position for one minute before the hydraulic fluid level is inspected. The level must be above the + mark after cycling the liftgate 3-5 times.

    Fig 1: Fluid Level Marks
    GM2215026Courtesy of GENERAL MOTORS COMPANY
  1. Cycle the liftgate 3-5 times to ensure proper fluid level.
  2. Inspect the fluid level. Refer to Liftgate Hydraulic Pump Replacement .
  3. If adding fluid is required, refer to Liftgate Hydraulic System Refilling .