Circuit/System Testing
Liftglass Ajar Switch Malfunction
- Ignition OFF, disconnect the harness connector at the liftgate window latch assembly.
- Test for less than 5 Ω between the ground circuit terminal 3 and ground.
- If greater than the specified range, test the ground circuit for an open/high resistance.
- Ignition ON, verify the scan tool Liftgate Ajar Switch parameter is Inactive.
- If not the specified value, test the signal circuit terminal 4 for a short to ground. If the circuit tests normal, replace the liftgate module.
- Install a 3A fused jumper wire between the signal circuit terminal 4 and ground. Verify the scan tool Liftgate Ajar Switch parameter is Active.
- If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the liftgate module.
- If all circuits test normal, test or replace the liftgate window latch assembly.
Liftgate Latch Assembly Malfunction
- Ignition OFF, disconnect the harness connector at the liftgate latch assembly.
- Ignition ON, verify the scan tool LGM Latch Ratchet Sw. parameter is Inactive.
- If not the specified value, test the signal circuit terminal 6 for a short to ground. If the circuit tests normal, replace the liftgate module.
- Install a 3A fused jumper wire between the signal circuit terminal 6 and ground. Verify the scan tool LGM Latch Ratchet Sw. parameter is Active.
- If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the liftgate module.
- If all circuits test normal, test or replace the liftgate latch assembly.