Installation Procedure
- Install the coolant temperature sensor and tighten to 22 N.m (16 lb ft).
- Install the coolant temperature sensor electrical connector.
- Slide the electrical connector heat protector (1) onto the electrical connector.
- Inspect and fill the cooling system as necessary. Refer to Cooling System Draining and Filling (Static Fill LF1, LLT) or Cooling System Draining and Filling (Static Fill LSA) or Cooling System Draining and Filling (GE 47716 LF1, LLT) or Cooling System Draining and Filling (GE 47716 LSA) .
CAUTION:
Refer to FASTENER CAUTION
.