Typical Scan Tool Data
IAT Sensor
| Circuit | Short to Ground | Open or High Resistance | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
Ignition ON or engine running Normal IAT Parameter: Varies with ambient temperature |
|||
| IAT Sensor Signal | 149°C (300°F) | -40°C (-40°F) | -40°C (-40°F)* |
| IAT Low Reference | - | -40°C (-40°F)* | - |
| *Internal ECM or sensor damage may occur if the circuit is shorted to B+ | |||