Component Testing
Coolant Pump Relay
- Ignition OFF, disconnect the INCLR relay.
- Test for 135-174 Ω between terminals 85 and 86.
- If the resistance is not within the specified range, replace the relay.
- Test for infinite resistance between the following terminals:
- 30 and 86
- 30 and 87
- 30 and 85
- 85 and 87
- If not the specified value, replace the relay.
- Install a 10A fused jumper wire between relay terminal 85 and 12V. Install a jumper wire between relay terminal 86 and ground. Test for less than 2Ω between terminals 30 and 87.
- If greater than the specified range, replace the relay.
CAC Pump Dynamic Test
- Install a 10A fused jumper wire between the B+ terminal B and 12V.
- Install a jumper wire between the ground terminal A and ground.
- Observe for the CAC pump to activate.
- If the CAC pump does not activate, replace the CAC pump