Fastener Tightening Specifications
Fastener Tightening Specifications
| Application | Specification | |
|---|---|---|
| Metric | English | |
| Battery Hold Down Retainer Bolt | 18 N.m | 13 lb ft |
| Battery Tray Bolt | 6 N.m | 53 lb in |
| Generator Bolt | 50 N.m | 37 lb ft |
| Generator Bracket Bolts (LH2) | 50 N.m | 37 lb ft |
| Generator Bracket Bolts (LY7) | 50 N.m | 37 lb ft |
| Generator Bracket Bolts (LY7) | 23 N.m | 17 lb ft |
| Generator BAT Terminal Nut | 10 N.m | 89 lb in |
| Ground Strap to Cam Cover Bolt (LH2) | 10 N.m | 89 lb in |
| Ground Strap to Cylinder Head Bolt (LH2) | 25 N.m | 18 lb ft |
| Negative Battery Cable Bolt | 17 N.m | 13 lb ft |
| Negative Battery Cable Ground to Cylinder Head Bolt (LH2) | 45 N.m | 33 lb ft |
| Negative Battery Cable Ground to Cylinder Head Bolt (LY7 - RHD) | 45 N.m | 33 lb ft |
| Negative Battery Cable Ground to Cylinder Head Stud (LY7) | 50 N.m | 37 lb ft |
| Negative Battery Cable Ground to Strut Tower Bolt (LH2) | 20 N.m | 15 lb ft |
| Negative Battery Cable Ground to Strut Tower Bolt (LY7) | 25 N.m | 18 lb ft |
| Positive Battery Cable Bolt | 17 N.m | 13 lb ft |
| Positive Battery Cable to Bussed Electrical Center (BEC) Stud Nut | 15 N.m | 11 lb ft |
| Positive Battery Cable to Generator BAT Terminal Nut | 10 N.m | 89 lb in |
| Positive Battery Cable to Starter BAT Terminal Nut | 10 N.m | 89 lb in |
| Starter Motor Bolt (LH2) | 30 N.m | 22 lb ft |
| Starter Motor Bolt (LY7) | 50 N.m | 37 lb ft |
| Starter Motor S Terminal Nut (LH2) | 4 N.m | 35 lb in |
| Transmission Lower Bellhousing Bolt (LY7) | 50 N.m | 37 lb ft |