Typical Scan Tool Data
CMP Solenoid Circuit Status
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
Engine running above 900 RPM in park Parameter Normal Range: Incomplete/OK |
|||
| CMP Solenoid | Short to GRD/Open | Short to GRD/Open | Short to B+ |
CMP Command
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
Engine running above 900 RPM in park Parameter Normal Range: 0-100% |
|||
| CMP Command | 0-100% | 0-100% | 0-100% |
Desired CMP
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
Engine running above 900 RPM in park Parameter Normal Range: 0-31° |
|||
| Desired CMP | 0-31° | 0-31° | 0-31° |
CMP Angle
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
Engine running above 900 RPM in park Parameter Normal Range: 0-31° |
|||
| CMP Angle | 0-31° | 0° | 0° |
CMP Variance
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
Engine running above 900 RPM in park Parameter Normal Range: 0° |
|||
| CMP Variance | 0-31° | 0-31° | 0-31° |