Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Cadillac >> 2005 >> XLR >> Repair and Diagnosis >> Quick Lookups >> Technical Bulletins >> Technical Service Bulletins >> Engine Control Systems >> Check Engine Light On, DTC P1101, P0068, P0171, P0174 (Reprogram ECM) (09-06-04-032A)

Check Engine Light On, DTC P1101, P0068, P0171, P0174 (Reprogram ECM) (09-06-04-032A)

Publication date: 2009-08-06
Reference number: 09-06-04-032A
Supersedes refnos: 09-06-04-032

Check Engine Light On, DTC P1101, P0068, P0171, P0174 (Reprogram ECM)

Check Engine Light On, DTC P1101, P0068, P0171, P0174 (Reprogram ECM)

TECHNICAL SERVICE BULLETIN

Reference Number(s): 09-06-04-032A, Date of Issue:  August 06, 2009
Affected Model(s): 2004-2006 Cadillac SRX, XLR; 2005-2006 Cadillac STS; Equipped with Engine RPO LH2; Please Refer to GMVIS
Supercedes: This bulletin is being revised to change the labor time information. Please discard Corporate Bulletin Number 09-06-04-032 (06 - Engine/Propulsion System)
Superceded Bulletin(s): 09-06-04-032, Date of Issue:  August 6, 2009

Condition

Some customers may comment on an illuminated check engine light shortly after a cold start with no engine performance concerns. Upon inspection, DTC P1101 (Intake Air Flow System Performance) may be set. In some instances, DTCs P0068 (Throttle Body Airflow Performance), P0171 (Fuel Trim System Lean Bank 1) and/or P0174 (Fuel Trim System Lean Bank 2) may eventually set as a result of the DTC P1101.

Correction

Verify the condition. If the diagnostics in SI for the conditions described above do not isolate a fault, reprogram the ECM with the revised calibration that has been developed to address this condition.

Verify that the multiple diagnostic interface (MDI) that is being used is configured to the PC that will be used.

Warranty Information

For vehicles reprogrammed under the 8 year/80,000 mile (130,000 km) emission controller warranty, use:

Warranty Information

Labor Operation Description Labor Time
J6353 Engine Control Module Engine Reprogramming with SPS 0.4 hr