Circuit Description
Heated Oxygen Sensor (HO2S) produces a voltage that varies between -100 mV and 900 mV under normal operating conditions. Full operating range of HO2S circuit is about from -406 mV to 1124 mV. ECM monitors this voltage and determines if exhaust is lean or rich. Oxygen sensor voltage is high when exhaust is rich, and low when exhaust is lean. ECM constantly monitors HO2S signal during closed loop operation and compensates for rich or lean condition by decreasing or increasing injector pulse width as necessary. If ECM detects low HO2S voltage for an extended period of time, this DTC will set.
Conditions required to set DTC are:
- HO2S voltage is between -39.8 mV and 38.3 mV.
- Condition is met for longer than 4 minutes.