Data Displays
When trouble shooting a malfunction, data displays can be used to compare vehicle with problems to a vehicle which is functioning properly. The following are a summary of each parameter for BCM:
- BD50 - BATTERY VOLTAGE
Battery voltage is read in volts between zero and 16.3. - BD51 - GENERATOR FIELD
Generator field is displayed in percent (%). A value close to zero % represents minimum regulator on time and a value close to 100% represents maximum regulator on time.