Removal & Installation
Discharge refrigerant system and remove electrical connector at rear of compressor. Remove snap ring and pull switch from cavity with pliers. Replace "O" ring in cavity lubricated with clean refrigerant oil. Install switch and snap ring, then pressurize compressor and check to see that switch is actuated between 20-30 psi. Evacuate and charge system.