Circuit/System Verification
WARNING: This page is about a different variant/trim than selected.
- Ignition OFF, measure and record the battery voltage at the C1 12V battery terminals. The battery voltage should stabilize between 12.4 and 12.8 V within a few minutes of turning the ignition OFF.
- If not within the specified range, refer to Battery Inspection/Test for Hybrid (HP6).
- Ignition ON, observe the scan tool Ignition 1 Signal parameter in the 14V Power Module data list. The parameter should be within 4.5 volts of the Low Voltage Circuit Voltage measured at the C1 12V battery.
- If the voltage is not within the specified range, check the ignition circuit to the K59 starter generator control module for high resistance.