Circuit/System Verification
- Verify the coolant level of the starter/generator cooling system is normal.
- If the coolant level is low
Inspect the starter/generator cooling system for any leaks.
- If the coolant level is normal
- If the coolant level is low
- Verify the starter/generator cooling system auxiliary radiator is clear of any debris, bent fins, or other damage which may inhibit airflow.
- If debris are found
Clean the auxiliary radiator.
- If damage is found
Replace the auxiliary radiator.
- If the coolant level is normal
- If debris are found
- Verify the starter/generator cooling system hoses are properly routed and are not kinked.
- If any hoses are improperly routed or kinked
Removed and properly route the hose.
- If all hoses are routed properly and are not kinked
- If any hoses are improperly routed or kinked
- Ignition ON.
- Verify the G22 starter/generator control module coolant pump turns ON and OFF when commanding the Motor Coolant Pump Relay Enable ON and OFF with a scan tool. The G22 starter/generator control module coolant pump will make an audible noise during operation.
- If the G22 starter/generator control module coolant pump does not turn ON and OFF
Refer to Circuit/System Testing .
- If the G22 starter/generator control module coolant pump turns ON and OFF
- If the G22 starter/generator control module coolant pump does not turn ON and OFF
- All OK.