Typical Scan Tool Data
TP Sensor 1
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
Engine Running Parameter Normal Range: 0.38-4.51 V |
|||
| TP Sensor 1 Signal | 0 V | 0 V | 5 V |
| TP Sensor 5-Volt Reference | 0 V | 0 V | 5 V |
| TP Sensor Low Reference | - | 5 V | - |
TP Sensor 2
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
Engine Running Parameter Normal Range: 0.28-4.60 V |
|||
| TP Sensor 2 Signal | 0 V | 5 V | 5 V |
| TP Sensor 5-Volt Reference | 0 V | 0 V | 5 V |
| TP Sensor Low Reference | - | 5 V | - |