Circuit Description
The engine control module (ECM) supplies a voltage near 450 mV between the heated oxygen sensor (HO2S) high signal circuit and the low reference circuit. The HO2S varies the voltage over a range from about 1,000 mV when the exhaust is rich, down through about 10 mV when the exhaust is lean.
The ECM monitors the HO2S voltage to determine if the signal voltage goes below a predetermined threshold within a certain amount of time. If the ECM determines that the signal voltage remains above a threshold, the ECM commands a lean condition. If the signal voltage does not go below the threshold within a certain amount of time after commanding the system lean, this DTC sets.
The ECM monitors the HO2S voltage during fuel cut-off. If the ECM determines that the signal voltage is greater than a predetermined voltage during fuel cut-off, this DTC sets.