Conditions for Meeting a Cold Start
- The ignition voltage between 11.0 and 18.0 volts
- The barometric pressure (BARO) is more than 75 kPa
- The start-up engine coolant temperature (ECT) is between 4-30°C (39-86°F)
- The start-up intake air temperature (IAT) is between 4-30°C (39-86°F).
- The difference between the IAT and the ECT is 6°C (10.8°F)
- The ambient air temperature is between 4-30°C (39-86°F)
- Fuel level is between 15 and 85 percent
- Vehicle has NOT been refueled since the last cold start ignition cycle