Diagnostic Aids
Using Tech 1 scan tool, select manual control function and cycle motor of affected channel in both directions while applying light pressure on brake pedal.
If erratic or jumpy brake pedal movement is detected while performing "apply" or "release" function of motor, intermittent fault code may be indicated. Intermittent problem may be caused by poor connection, rubbed-through wire insulation or broken wire inside insulation.
If fault is not current, wiggle wires of affected channel, and check if code resets. This will help pinpoint intermittent problem in motor circuit or connections. Enhanced diagnostic feature Tech 1 scan tool can be used to check frequency of problem.