All Models: Replacement
- Disconnect thermal limiter plug and discharge system. Clean all dirt and grease from exterior surface of EEVIR assembly. With system fully discharged, loosen receiver-drier shell retaining screws three turns. Disconnect mounting bracket from receiver shell. Hold EEVIR housing and push on lower end of receiver shell to break seal.
- Remove retaining bolts and shell by lowering downward to clear pickup tube and filter. Remove and discard desiccant bag and "O" ring. Drain and discard any oil in receiver shell. Clean filter screen and interior of shell. To install, reverse removal procedure. Lubricate new "O" ring with refrigerant oil. Evacuate, leak test, and charge system.