Mike's Workshop Manuals: Service manuals for every vehicle
Home >> BMW >> 1994 >> 325is Standard >> Repair and Diagnosis >> Transmission >> Automatic Trans >> Electronic Transmission Control >> Diagnostic Tests >> DTC 22: Oil Sump Temperature Sensor >> Effect Of Defect

Effect Of Defect

A substitute value of 212°F (100°C) is used. Transmission oil has overheated or aged prematurely. It is recommended to change the transmission oil.