Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Audi >> 2021 >> A8 e Quattro >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Generic Scan Tool [CZSE] (Hybrid) - HVAC Module DTC Tables (P26AB - B3A1C) >> St Generic Scan Tool >> Diagnosis And Testing >> HVAC Module >> HVAC Module --, 2021 MY

HVAC Module --, 2021 MY

Component / System (Official) Fault Code (SAE-Code) Monitor Strategy Description English Malfunction Criteria English Threshold Value Unit Secondary Parameters Enable Condition Unit Monitor (Frequency of Checks) Monitoring Time Length Unit MIL Illum.
              = charging / preconditioning [-]        
      OR          
      = drive ready [-]        
      OR          
      = ignition on / preconditioning [-]        
      OR          
      = ignition on / preconditioning / charging [-]        
      OR          
      = drive ready / preconditioning [-]        
    Requested position of the engine coolant bypass valve "A" = heat circuit excluding combustion engine [-)        
    Vehicle speed < 255 [km/h]        
    Ambient temperature > -255 [°C]        
    Minimum temperature of the engine coolant temperature sensor 3 or the engine coolant temperature sensor 2 > -255 [°C]        
    Difference between the ambient temperature and the minimum temperature of the heat circuit < 255 [K]        
    Engine coolant temperature sensor 3 < 255 [°C]        
    Maximum time of the monitoring < 6, 553.5 [s]        
    Actual tuned volume flow of the combustion engine circuit ≥ 0 [l/min]        
    Debounce time for reaching a homogeneous temperature of the combustion engine circuit > 0 [s]        
    Actual tuned volume flow of the heat circuit ≥ 2.9 [l/min]        
    Debounce time for reaching a homogeneous temperature of the heat circuit > 35 [s]        
    Rest period of the heat circuit > 100 [min]        
    Difference of the actual temperature and the temperature measured at monitoring start of the engine coolant temperature sensor 1 ≤ 3, 267.7...3, 276.7 [K]        
    (Difference of the actual temperature and the temperature measured at monitoring start of the engine coolant temperature sensor 3 > 26 [K]        
    OR            
    Difference of the actual temperature and the temperature measured at monitoring start of the engine coolant temperature sensor 2) > 30 [K]        
    Coolant pump "B" electrical monitoring = passed [-]        
    Coolant pump "B" functional monitoring = passed [-]        
    Coolant pump "A" electrical monitoring = passed [-]        
    Coolant pump "A" functional monitoring = passed [-]        
  P26AB Stuck open CASE 1: Delta value between the engine coolant temperature sensor 2 and the combustion engine coolant temperature     Ignition on > 500 [ms] continuous 100 [ms] 2 DCY
    Delta value between engine coolant temperature sensor 2 and combustion engine coolant temperature > 30 [K] Engine coolant bypass valve "A" electrical monitoring = passed [-]        
          Engine coolant temperature sensor 2 electrical monitoring = passed [-]        
          Engine control module/Powertrain control module communication monitoring = passed [-]        
          Body control module monitoring = passed [-]        
    Case 2: Delta value between the engine coolant temperature sensor 2 and the combustion engine coolant temperature due to convection factor     Status of the ambient temperature = valid [-]        
    Delta value between engine coolant temperature sensors 2 and combustion engine coolant temperature > 18...18 [K] Anti-lock-brake system control module communication monitoring = passed [-]        
          Engine coolant temperature sensor 3 electrical monitoring = passed [-]        
          Engine coolant temperature sensor 1 electrical monitoring = passed [-]        
          Internal system operation mode for engine coolant bypass valve "A" stuck open monitoring = drive ready [-]        
            OR          
            = drive ready / preconditioning [-]        
          Requested position of the engine coolant bypass valve "A" = heat circuit including combustion engine [-]        
          Actual tuned volume flow in the combustion engine circuit ≥ 0 [l/min]        
          Debounce time for a homogeneous temperature of the combustion engine circuit > 0 [s]        
          Actual tuned volume flow in the heat circuit ≥ 6 [l/min]        
          Debounce time for a homogeneous temperature of the heat circuit > 20 [s]        
          Minimum temperature of the engine coolant temperature sensor 2 and the engine coolant temperature sensor 3 > -255 [l/min]        
          Engine speed ≤ 0 [rpm]        
          Vehicle speed ≤ 255 [km/h]        
          Ambient temperature ≥ -255 [°C]        
          Minimum temperature of the combustion engine coolant temperature, the engine coolant temperature sensor 2 and the engine coolant temperature sensor 3 > -255 [°C]        
          Difference between the minimum temperature of the heat circuit and the ambient temperature < 255 [K]        
          Combustion engine coolant temperature ≤ 255 [°C]        
          Debounce time 1 after combustion engine shut off ≤ 6, 553.5 [s]        
          Debounce time 2 after combustion engine shut off ≤ 6, 553.5 [s]        
          Coolant pump "B" electrical monitoring = passed [-]        
          Coolant pump "B" functional monitoring = passed [-]        
          Coolant pump "A" electrical monitoring = passed [-]        
          Coolant pump "A" functional monitoring = passed [-]        
                       
          Additionally for CASE 2:            
          (Delta value of the coolant temperature prior to the heat register at monitoring start and during monitoring measured with the engine coolant temperature sensor 2 > 20 [K]        
          OR            
          Delta value of the combustion engine coolant temperature at monitoring start and during monitoring) > 20 [K]        
Hybrid/EV Battery Pack Coolant Control Valve "C" P0DE8 Control circuit open Case 1: On-State     Case 1: On-State     continuous 300 [ms] 2 DCY
      Current consumption < 40 [mA] Valve = commanded on [-]        
      Case 2: Off-State     Case 1: Off-State            
      High-side-out driver = output toggles [-] Valve = commanded off [-]        
  P0DEB Control circuit low Voltage drop at high-side out > 1.5 [V] Valve = commanded on [-] continuous 300 [ms] 2 DCY
  P0DEC Control circuit high Measured voltage at high-side out = battery voltage [V] Valve = commanded off [-] continuous 300 [ms] 2 DCY
  P0DEA Stuck on Delta temperature 2 > 5 [K] Ignition on > 500 [ms] continuous 100 [ms] 2 DCY
    OR     Battery energy control module "B" communication monitoring = passed [-]        
    Delta temperature change > 5 [K] Hybrid/EV battery pack coolant control valve "C" electrical monitoring = passed [-]        
          Hybrid/EV battery pack coolant temperature sensor "B" electrical monitoring = passed [-]        
    For detailed information about "delta temperature 2" and "delta temperature change" please refer to the "Technical Description"     Internal system operation mode for hybrid/EV battery pack coolant control valve "C" stuck monitoring = preconditioning [-]        
            OR          
            = charging / preconditioning [-]        
            OR          
            = charging [-]        
            OR          
            = ignition on [-]        
            OR          
            = ignition / charging [-]        
            OR          
            = drive ready [-]        
            OR          
            = ignition on / preconditioning [-]        
            OR          
            = ignition on / preconditioning / charging [-]        
            OR          
            = drive ready / preconditioning [-]        
          Hybrid/EV battery pack coolant control valve "A" electrical monitoring = passed [-]        
          Coolant bypass valve "A" electrical monitoring = passed [-]        
          Duty cycle of the hybrid/EV battery pack coolant pump > 50 [%]        
          Requested position of the hybrid/EV battery pack coolant control valve "C" = battery circuit including the high-voltage battery [-]        
          Position of the hybrid/EV battery pack coolant control valve "A" = unchanged [-]        
          (Position of the hybrid/EV battery pack coolant control valve "C" = unchanged [-]        
          OR            
          Requested position of the hybrid/EV battery pack coolant control valve "A") = electromachine circuit [-]        
          Debounce time for activating the monitoring ≥ 60 [s]        
          Absolute value of delta temperature 1 > 8 [K]        
          (For detailed information about "delta temperature 1" please refer to the Technical Description)            
  P0DE9 Performance/stuck off Delta temperature 2 < 3 [K] Ignition on > 500 [ms] continuous 100 [ms] 2 DCY
    OR     Battery energy control module "B" communication monitoring = passed [-]        
    Delta temperature change < 3 [K] Hybrid/EV battery pack coolant control valve "C" electrical monitoring = passed [-]        
          Hybrid/EV battery pack coolant temperature sensor "B" electrical monitoring = passed [-]        
    For detailed information about "delta temperature 2" and "delta temperature change" please refer to the "Technical Description"     Internal system operation mode for hybrid/EV battery pack coolant control valve "C" stuck monitoring = preconditioning [-]        
            OR          
            = charging / preconditioning [-]        
            OR          
            = charging [-]        
            OR          
            = ignition on [-]        
            OR          
            = ignition / charging [-]        
            OR          
            = drive ready [-]        
            OR          
            = ignition on / preconditioning [-]        
            OR          
            = ignition on / preconditioning / charging [-]        
            OR          
            = drive ready / preconditioning [-]        
          Hybrid/EV battery pack coolant control valve "A" electrical monitoring = passed [-]        
          Coolant bypass valve "A" electrical monitoring = passed [-]        
          Duty cycle of the hybrid/EV battery pack coolant pump > 50 [%]        
          Requested position of the hybrid/EV battery pack coolant control valve "C" = battery circuit excluding the high-voltage battery [-]        
          Position of the hybrid/EV battery pack coolant control valve "A" = unchanged [-]        
          (Position of the hybrid/EV battery pack coolant control valve "C" = unchanged [-]        
          OR            
          Requested position of the hybrid/EV battery pack coolant control valve "A") = electromachine circuit [-]        
          Debounce time for activating the monitoring ≥ 60 [s]        
          Absolute value of delta temperature 1 > 8 [K]        
          (For detailed information about "delta temperature 1" please refer to the Technical Description)            
Cooling fan 1 enable P1A75 Circuit open Voltage at input/output < 2 [V] Output current < 275 [μA] continuous 500 [ms] 2 DCY
  P1A76 Circuit low Output current > 30 [mA] none   [-] continuous 500 [ms] 2 DCY

Table continues below

Component / System (Official) Fault Code (SAE-Code) Monitor Strategy Description English Malfunction Criteria English Threshold Value Unit Secondary Parameters Enable Condition Unit Monitor (Frequency of Checks) Monitoring Time Length Unit MIL Illum.
  P1A77 Circuit high Voltage at input/output > 3 [V] Output current < 275 [μA] continuous 500 [ms] 2 DCY
Cooling Fan 1 P0480 Control circuit open Voltage PWM signal amplitude < 5 [V] Electronics of the cooling fan 1 electrical monitoring = passed [-] continuous 500 [ms] 2 DCY
  P0691 Control circuit low Constant voltage < 1.7 [V] Electronics of the cooling fan 1 electrical monitoring = passed [-] continuous 500 [ms] 2 DCY
    for a period of time ≥ 4.5 [s]     [-]        
  P0692 Control circuit high Constant voltage > 1.7 [V] Electronics of the cooling fan 1 electrical monitoring = passed [-] continuous 500 [ms] 2 DCY
  U0632 Lost communication with fan actuator No response 3 times in a row = failed [-] Electronics of the cooling fan 1 electrical monitoring = passed [-] other event n/a [-] 2 DCY
    OR   No over voltage / under voltage [-]        
    Response of variant [-]            
  P1A7B Incorrect component installed Received variant != variant stored in data set [-] Electronics of the cooling fan 1 electrical monitoring = passed [-] other event n/a [-] 2 DCY
    No over voltage / under voltage [-]        
  P2B30 Stuck on (blockade) tlow signal = 2 [s] Ignition on > 500 [ms] continuous 339 [s] 2 DCY
    Supply voltage of the actuator > 9.3 [V]        
      < 18.4 [V]        
    Electronics of the cooling fan 1 electrical monitoring = passed [-]        
    Cooling fan 1 electrical monitoring = passed [-]        
    Body control module communication monitoring = passed [-]        
    Engine control module/powertrain control module communication monitoring = passed [-]        
    Combustion engine speed > 0 [rpm]        
    { (Ambient temperature after initialization > 4 [°C]        
    OR            
    Ambient temperature during initialization) ≥ 4 [°C]        
    OR            
    [(Ambient temperature after initialization < -255 [°C]        
    OR            
    Ambient temperature during initialization) < 4 [°C]        
    AND            
    (Timer of the cumulative engine run ≥ 6, 553.5 [s]        
    OR            
    Timer of the continuous engine run '≥ 300 [s]        
    OR            
    Status of the cooling needs for the high-voltage battery '≥ 127 [-]        
    OR            
    Status of the cooling needs for the inverter) ] } '≥ 127 [-]        
  P2B2F Performance/stuck off (internal error) tlow signal = 4 [s] Supply voltage of the actuator > 9.3 [V] continuous 410 [s] 2 DCY
      < 18.4 [V]        
    Electronics of the cooling fan 1 electrical monitoring = passed [-]        
  P2B2F Performance/stuck off (overheating) tlow signal = 1 [s] Supply voltage of the actuator > 9.3 [V] continuous 606 [s] 2 DCY
      < 18.4 [V]        
    Electronics of the cooling fan 1 electrical monitoring = passed [-]        
    Commanded cooling fan speed ≥ 15 [%]        
    Cooling fan 1 performance/stuck off (internal error) monitoring = passed [-]        
Cooling Fan 2 Enable P1A78 Circuit open Voltage at input/output < 2.0 [V] Output current < 275 [μA] continuous 500 [ms] 2 DCY
  P1A79 Circuit low Output current > 30 [mA] none   [-] continuous 500 [ms] 2 DCY
  P1A7A Circuit high Voltage at input/output > 3 [V] Output current < 275 [μA] continuous 500 [ms] 2 DCY
Cooling Fan 2 P0481 Control circuit open Voltage PWM signal amplitude < 5 [V] Electronics of the cooling fan 2 electrical monitoring = passed [-] continuous 500 [ms] 2 DCY
  P0693 Control circuit low Constant voltage < 1.7 [V] Electronics of the cooling fan 2 electrical monitoring = passed [-] continuous 500 [ms] 2 DCY
    for a period of time ≥ 4.5 [s]     [-]        
  P0694 Control circuit high Constant voltage > 1.7 [V] Electronics of the cooling fan 2 electrical monitoring = passed [-] continuous 500 [ms] 2 DCY
  U0633 Lost communication with fan actuator No response 3 times in a row = failed [-] Electronics of the cooling fan 2 electrical monitoring = passed [-] other event n/a [-] 2 DCY
    OR   No over voltage / under voltage [-]        
    Response of variant [-]            
  P1A7C Incorrect component installed Received variant != variant stored in data set [-] Electronics of the cooling fan 2 electrical monitoring = passed [-] other event n/a [-] 2 DCY
    No over voltage / under voltage [-]        
  P2B32 Stuck on (blockade) tlow signal = 2 [s] Ignition on > 500 [ms] continuous 339 [s] 2 DCY
    Supply voltage of the actuator > 9.3 [V]        
      < 18.4 [V]        
    Electronics of the cooling fan 2 electrical monitoring = passed [-]        
    Cooling fan 2 electrical monitoring = passed [-]        
    Body control module communication monitoring = passed [-]        
    Engine control module/powertrain control module communication monitoring = passed [-]        
    Combustion engine speed > 0 [rpm]        
    { (Ambient temperature after initialization > 4 [°C]        
    OR            
    Ambient temperature during initialization) ≥ 4 [°C]        
    OR            
    [(Ambient temperature after initialization < -255 [°C]        
    OR            
    Ambient temperature during initialization) < 4 [°C]        
    AND            
    (Timer of the cumulative engine run ≥ 6, 553.5 [s]        
    OR            
    Timer of the continuous engine run '≥ 300 [s]        
    OR            
    Status of the cooling needs for the high-voltage battery '≥ 127 [-]        
    OR            
    Status of the cooling needs for the inverter) ] } ' ≥ 127 [-]        
  P2B31 Performance/stuck off (internal error) tlow signal = 4 [s] Supply voltage of the actuator > 9.3 [V] continuous 410 [s] 2 DCY
      < 18.4 [V]        
    Electronics of the cooling fan 2 electrical monitoring = passed [-]        
  P2B31 Performance/stuck off (overheating) tlow signal = 1 [s] Supply voltage of the actuator > 9.3 [V] continuous 606 [s] 2 DCY
      < 18.4 [V]        
    Electronics of the cooling fan 2 electrical monitoring = passed [-]        
    Commanded cooling fan speed ≥ 15 [%]        
    Cooling fan 2 performance/stuck off (internal error) monitoring = passed [-]        
Data Set A B2005 Checksum incompatibility Actual checksum != stored checksum [-] None   [-] continuous 1.000 [ms] 1 DCY
  B2012 Software version number incompatibility Actual software version number != stored software version number [-] None   [-] continuous 1.000 [ms] 1 DCY
  C2001 Software version number incompatibility Actual software version number != stored software version number [-] Ignition on > 500 [ms] continuous 1.000 [ms] 1 DCY
  B2012 Software spare part number incompatibility Actual software spare part number != stored software spare part number [-] None   [-] continuous 1.000 [ms] 1 DCY
  C2001 Software spare part number incompatibility Actual software spare part number != stored software spare part number [-] Ignition on > 500 [ms] continuous 1.000 [ms] 1 DCY
  B2012 Hardware version number incompatibility Actual hardware version number != stored hardware version number [-] None   [-] continuous 1.000 [ms] 1 DCY
  C2001 Motor code incompatibility Actual motor code != stored motor code [-] Ignition on > 500 [ms] continuous 1.500 [ms] 1 DCY
    Engine control module communication monitoring = passed [-]        
  C2001 Fuel type incompatibility Actual fuel type != stored fuel type [-] Ignition on > 500 [ms] continuous 1.500 [ms] 1 DCY
    Engine control module communication monitoring = passed [-]        
  C2001 Vehicle type incompatibility Actual vehicle type != stored vehicle type [-] Ignition on > 500 [ms] continuous 1.500 [ms] 1 DCY
    Engine control module communication monitoring = passed [-]        
  C2001 OBD type incompatibility Actual OBD type != stored OBD type [-] Ignition on > 500 [ms] continuous 1.500 [ms] 1 DCY
    Engine control module communication monitoring = passed [-]        
  C2001 Vehicle identification number incompatibility Actual vehicle identification number != stored vehicle identification number [-] Ignition on > 500 [ms] continuous 2.000 [ms] 1 DCY
    Engine control module communication monitoring = passed [-]        
Data Set B B2005 Checksum incompatibility Actual checksum != stored checksum [-] None   [-] continuous 1.000 [ms] 1 DCY
  B2012 Software version number incompatibility Actual software version number != stored software version number [-] None   [-] continuous 1.000 [ms] 1 DCY
  B2012 Software spare part number incompatibility Actual software spare part number != stored software spare part number [-] None   [-] continuous 1.000 [ms] 1 DCY
  B2012 Hardware version number incompatibility Actual hardware version number != stored hardware version number [-] None   [-] continuous 1.000 [ms] 1 DCY
  C2002 Motor code incompatibility Actual motor code != stored motor code [-] Ignition on > 500 [ms] continuous 960 [ms] 1 DCY
    Engine first start [-]        
  C2002 Fuel type incompatibility Actual fuel type != stored fuel type [-] Ignition on > 500 [ms] continuous 960 [ms] 1 DCY
    Engine first start [-]        
  C2002 Vehicle type incompatibility Actual vehicle type != stored vehicle type [-] Ignition on > 500 [ms] continuous 960 [ms] 1 DCY
    Engine first start [-]        
  C2002 OBD type incompatibility Actual OBD type != stored OBD type [-] Ignition on > 500 [ms] continuous 960 [ms] 1 DCY
    Engine first start [-]        
  C2002 Vehicle identification number incompatibility Actual vehicle identification number != stored vehicle identification number [-] Ignition on > 500 [ms] continuous 200 [ms] 1 DCY
    Engine first start [-]        
A/C Refrigerant Distribution Valve "A" P1A87 Incorrect component installed Current software version number != software version number stored in the data base [-] none   [-] other event n/a [-] 2 DCY
  P1A8C Wrong address (hardware address) Stored hardware address ' != Own hardware address [-] Plausibility check = active [-] other event n/a [-] 2 DCY
  P0EC9 Actuator stuck open (blockade) Blockade monitoring = failed [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Blockade monitoring test cycle = completed [-] A/C refrigerant distribution valve "A" communication monitoring = passed [-]        
  P2611 Actuator control circuit open (electrical error) Electrical monitoring = failed [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Electrical monitoring test cycle = completed [-] A/C refrigerant distribution valve "A" communication monitoring = passed [-]        
  P2611 Actuator control circuit open (temperature sensor error) Temperature sensor monitoring = failed [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Temperature sensor monitoring test cycle = completed [-] A/C refrigerant distribution valve "A" communication monitoring = passed [-]        
  P1A8C Wrong address Own hardware address ' != hardware address to be stored in the flash memory [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Wrong address monitoring test cycle = completed [-] A/C refrigerant distribution valve "A" communication monitoring = passed [-]        
  P2613 Actuator control circuit high (over voltage) Supply voltage > 18.5 [V] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Over voltage monitoring test cycle = completed [-] A/C refrigerant distribution valve "A" communication monitoring = passed [-]        
  P266F Actuator control circuit driver current/temperature too high Driver temperature > 170 [°C] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Over temperature monitoring test cycle = completed [-] A/C refrigerant distribution valve "A" communication monitoring = passed [-]        
  P2612 Actuator control circuit low (under voltage) Supply voltage < 7.8 [V] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Under voltage monitoring test cycle = completed [-] A/C refrigerant distribution valve "A" communication monitoring = passed [-]        
  B3A13 Actuator control circuit performance (response error) Communication error = checksum error [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
      = stop bit error [-] A/C refrigerant distribution valve "A" communication monitoring = passed [-]        
    Actuator control circuit performance monitoring test cycle = completed [-]              
  B3A14 Actuator temperature range/performance (out of range high) Temperature of the A/C refrigerant distribution valve "A" > 160 [°C] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
      < 204 [°C] A/C refrigerant distribution valve "A" communication monitoring = passed [-]        
    Temperature out of range high monitoring test cycle = completed [-]              
  B3A13 Actuator control circuit performance (actuator speed) Actuator speed monitoring = failed [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Actuator speed monitoring test cycle = completed [-] A/C refrigerant distribution valve "A" communication monitoring = passed [-]  

Table continues below

Component / System (Official) Fault Code (SAE-Code) Monitor Strategy Description English Malfunction Criteria English Threshold Value Unit Secondary Parameters Enable Condition Unit Monitor (Frequency of Checks) Monitoring Time Length Unit MIL Illum.
  B3A13 Actuator control circuit performance (actuator position) Actuator position monitoring = failed [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Actuator position monitoring test cycle = completed [-] A/C refrigerant distribution valve "A" communication monitoring = passed [-]  
  B3A13 Actuator control circuit performance (coil holding current) Coil holding monitoring = failed [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Coil holding monitoring test cycle = completed [-] A/C refrigerant distribution valve "A" communication monitoring = passed [-]  
  B3A13 Actuator control circuit performance (PCB temperature) PCB temperature ≥ 204 [°C] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    PCB temperature monitoring test cycle = completed [-] A/C refrigerant distribution valve "A" communication monitoring = passed [-]  
  P0EC9 Actuator stuck/open (position crosscheck) CASE 1: Delta between the actual and the target position     Ignition on > 500 [ms] continuous 100 [ms] 2 DCY
    Delta value between the actual and the target opening position of the A/C refrigerant distribution valve "A" > 4 [%] A/C refrigerant distribution valve "A" communication monitoring = passed [-]        
          A/C refrigerant distribution valve "A" electrical monitoring = passed [-]        
    CASE 2: Quick test of the actuator positioning                  
    Travel distance of the actuator of the A/C refrigerant distribution valve "A" ≥ 6 [%] Additionally for CASE 1:            
    Delta between the reference and the target position of the A/C refrigerant distribution valve "A" ≥ 19 [%] Delta value of the target position of the A/C refrigerant distribution valve "A" < 1.4 [%]        
          Time the A/C refrigerant distribution valve "A" must remain nearly in the same position > 10 [s]        
          Delta value between the reference and the target position of the A/C refrigerant distribution valve "A" > 6 [%]        
                       
          Additionally for CASE 2:            
          (Delta value of the target position of the A/C refrigerant distribution valve "A" > 19 [%]        
          OR            
          Delta value between the target and the actual opening position of the A/C refrigerant distribution valve "A") ≥ 100 [%]        
          Time the A/C refrigerant distribution valve "A" must remain nearly in the same position > 2.4 [s]        
  B3A14 Actuator temperature range/performance Temperature deviation of the internal temperature of the A/C refrigerant distribution valve "A" to the median value of the internal temperatures of the A/C refrigerant distribution valve "A", the A/C refrigerant distribution valve "B", the A/C refrigerant distribution valve "C", the A/C refrigerant distribution valve "D" and the A/C refrigerant expansion valve ≥ 18α[EURO SIGN] | 16 [K] Ignition on > 500 [ms] continuous 100 [ms] 2 DCY
    A/C refrigerant distribution valve "A" electrical monitoring = passed [-]        
    A/C refrigerant distribution valve "B" electrical monitoring = passed [-]        
    A/C refrigerant distribution valve "C" electrical monitoring = passed [-]        
    A/C refrigerant distribution valve "D" electrical monitoring = passed [-]        
    A/C refrigerant expansion valve electrical monitoring = passed [-]        
    Debounce time for the global conditions > 4 [s]        
    Rest period of the refrigerant circuit > 360 [min]        
    Internal system operation mode = preconditioning [-]        
      OR          
      = charging/preconditioning [-]        
      OR          
      = charging [-]        
      OR          
      = ignition on [-]        
      OR          
      = ignition on/charging [-]        
      OR          
      = drive ready [-]        
      OR          
      = ignition on/preconditioning [-]        
      OR          
      = ignition on/charging/preconditioning [-]        
      OR          
      = drive ready/preconditioning [-]        
    Timer to limit the activation of the temperature crosscheck monitoring depending on the internal system operation mode < 300 [s]        
    Communication monitoring of the coolant pump "A" = passed [-]        
    Functional monitoring of the coolant pump "A" = passed [-]        
    Communication monitoring of the hybrid/EV electronics coolant pump = passed [-]        
    Functional monitoring of the hybrid/EV electronics coolant pump = passed [-]        
    Communication monitoring of the coolant pump "B" = passed [-]        
    Functional monitoring of the coolant pump "B" = passed [-]        
    Communication monitoring of the battery energy control module = passed [-]        
                 
    Cold Start Conditions            
    Debounce time for cold start conditions > 0 [s]        
    Temperature gradient of the A/C refrigerant distribution valve "A" for cold start conditions < 10 [K]        
    Temperature gradient of the A/C refrigerant distribution valve "B" for cold start conditions < 10 [K]        
    Temperature gradient of the A/C refrigerant distribution valve "C" for cold start conditions < 10 [K]        
    Temperature gradient of the A/C refrigerant distribution valve "D" for cold start conditions < 10 [K]        
    Temperature gradient of the A/C refrigerant expansion valve for cold start conditions < 10 [K]        
A/C Refrigerant Distribution Valve "B" P1A89 Incorrect component installed Current software version number != software version number stored in the data base [-] none   [-] other event n/a [-] 2 DCY
  P1A8D Wrong address (Hardware address) Stored hardware address != Own hardware address [-] Plausibility check = active [-] other event n/a [-] 2 DCY
  P0EE2 Actuator stuck open (blockade) Blockade monitoring = failed [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Blockade monitoring test cycle = completed [-] A/C refrigerant distribution valve "B" communication monitoring = passed [-]        
  P0EE3 Actuator control circuit open (electrical error) Electrical monitoring = failed [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Electrical monitoring test cycle = completed [-] A/C refrigerant distribution valve "B" communication monitoring = passed [-]        
  P0EE3 Actuator control circuit open (temperature sensor error) Temperature sensor monitoring = failed [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Temperature sensor monitoring test cycle = completed [-] A/C refrigerant distribution valve "B" communication monitoring = passed [-]        
  P1A8D Wrong address Own hardware address != hardware address to be stored in the flash memory [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Wrong address monitoring test cycle = completed [-] A/C refrigerant distribution valve "B" communication monitoring = passed [-]        
  P0EE5 Actuator control circuit high (over voltage) Supply voltage > 18.5 [V] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Over voltage monitoring test cycle = completed [-] A/C refrigerant distribution valve "B" communication monitoring = passed [-]        
  P0EE6 Control circuit driver current/temperature too high Driver temperature > 170 [°C] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Over temperature monitoring test cycle = completed [-] A/C refrigerant distribution valve "B" communication monitoring = passed [-]        
  P0EE4 Actuator control circuit low (under voltage) Supply voltage < 7.8 [V] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Under voltage monitoring test cycle = completed [-] A/C refrigerant distribution valve "B" communication monitoring = passed [-]        
  B3A15 Actuator control circuit performance (response error) Communication error = checksum error [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
      = stop bit error [-] A/C refrigerant distribution valve "B" communication monitoring = passed [-]        
    Actuator control circuit performance monitoring test cycle = completed [-]              
  B3A16 Actuator temperature range/performance (out of range high) Temperature of the A/C refrigerant distribution valve "B" > 160 [°C] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
      < 204 [°C] A/C refrigerant distribution valve "B" communication monitoring = passed [-]        
    Temperature out of range high monitoring test cycle = completed [-]              
  B3A15 Actuator control circuit performance (actuator speed) Actuator speed monitoring = failed [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Actuator speed monitoring test cycle = completed [-] A/C refrigerant distribution valve "B" communication monitoring [-]  
  B3A15 Actuator control circuit performance (actuator position) Actuator position monitoring = failed [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Actuator position monitoring test cycle = completed [-] A/C refrigerant distribution valve "B" communication monitoring [-]  
  B3A15 Actuator control circuit performance (coil holding current) Coil holding monitoring = failed [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Coil holding monitoring test cycle = completed [-] A/C refrigerant distribution valve "B" communication monitoring [-]  
  B3A15 Actuator control circuit performance (PCB temperature) PCB temperature ≥ 204 [°C] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    PCB temperature monitoring test cycle = completed [-] A/C refrigerant distribution valve "B" communication monitoring [-]  
  P0EE2 Actuator stuck/open (position crosscheck) CASE 1: Delta between the actual and the target position     Ignition on > 500 [ms] continuous 100 [ms] 2 DCY
    Delta value between the actual and the target opening position of the A/C refrigerant distribution valve "B" > 4 [%] A/C refrigerant distribution valve "B" communication monitoring = passed [-]        
          A/C refrigerant distribution valve "B" electrical monitoring = passed [-]        
    CASE 2: Quick test of the actuator positioning                  
    Travel distance of the actuator of the A/C refrigerant distribution valve "B" ≥ 6 [%] Additionally for CASE 1:            
    Delta between the reference and the target position of the A/C refrigerant distribution valve "B" ≥ 19 [%] Delta value of the target position of the A/C refrigerant distribution valve "B" < 1.4 [%]        
          Time the A/C refrigerant distribution valve "B" must remain nearly in the same position > 10 [s]        
          Delta value between the reference and the target position of the A/C refrigerant distribution valve "B" > 6 [%]        
                       
          Additionally for CASE 2:            
          (Delta value of the target position of the A/C refrigerant distribution valve "B" > 19 [%]        
          OR            
          Delta value between the target and the actual opening position of the A/C refrigerant distribution valve "B") ≥ 100 [%]        
          Time the A/C refrigerant distribution valve "B" must remain nearly in the same position > 2.4 [s]        
  B3A16 Actuator temperature range/performance Temperature deviation of the internal temperature of the A/C refrigerant distribution valve "B" to the median value of the internal temperatures of the A/C refrigerant distribution valve "A", the A/C refrigerant distribution valve "B", the A/C refrigerant distribution valve "C", the A/C refrigerant distribution valve "D" and the A/C refrigerant expansion valve ≥ 18...16 [K] Ignition on > 500 [ms] continuous 100 [ms] 2 DCY
    A/C refrigerant distribution valve "A" electrical monitoring = passed [-]        
    A/C refrigerant distribution valve "B" electrical monitoring = passed [-]        
    A/C refrigerant distribution valve "C" electrical monitoring = passed [-]        
    A/C refrigerant distribution valve "D" electrical monitoring = passed [-]        
    A/C refrigerant expansion valve electrical monitoring = passed [-]        
    Debounce time for the global conditions > 4 [s]        
    Rest period of the refrigerant circuit > 360 [min]        
    Internal system operation mode = preconditioning [-]        
      OR          
      = charging/preconditioning [-]        
      OR          
      = charging [-]        
      OR          
      = ignition on [-]        
      OR          
      = ignition on/charging [-]        
      OR          
      = drive ready [-]        
      OR          
      = ignition on/preconditioning [-]        
      OR          
      = ignition on/charging/preconditioning [-]        
      OR          
      = drive ready/preconditioning [-]        
    Timer to limit the activation of the temperature crosscheck monitoring depending on the internal system operation mode < 300 [s]        
    Communication monitoring of the coolant pump "A" = passed [-]        
    Functional monitoring of the coolant pump "A" = passed [-]        

Table continues below

Component / System (Official) Fault Code (SAE-Code) Monitor Strategy Description English Malfunction Criteria English Threshold Value Unit Secondary Parameters Enable Condition Unit Monitor(Frequency of Checks) Monitoring Time Length Unit MIL Illum.
                         
            Communication monitoring of the hybrid/EV electronics coolant pump = passed [-]        
    Functional monitoring of the hybrid/EV electronics coolant pump = passed [-]        
    Communication monitoring of the coolant pump "B" = passed [-]        
    Functional monitoring of the coolant pump "B" = passed [-]        
    Communication monitoring of the battery energy control module = passed [-]        
                 
    Cold Start Conditions            
    Debounce time for cold start conditions > 0 [s]        
    Temperature gradient of the A/C refrigerant distribution valve "A" for cold start conditions < 10 [K]        
    Temperature gradient of the A/C refrigerant distribution valve "B" for cold start conditions < 10 [K]        
    Temperature gradient of the A/C refrigerant distribution valve "C" for cold start conditions < 10 [K]        
    Temperature gradient of the A/C refrigerant distribution valve "D" for cold start conditions < 10 [K]        
    Temperature gradient of the A/C refrigerant expansion valve for cold start conditions < 10 [K]        
A/C Refrigerant Distribution Valve "C" P1A8A Incorrect component installed Current software version number != software version number stored in the data base [-] none   [-] other event n/a [-] 2 DCY
  P1A8E Wrong address (Hardware address) Stored hardware address != own hardware address [-] Plausibility check = active [-] other event n/a [-] 2 DCY
  B3A00 Actuator stuck open (blockade) Blockade monitoring = failed [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Blockade monitoring test cycle = completed [-] A/C refrigerant distribution valve "C" communication monitoring = passed [-]        
  B3A01 Actuator control circuit open (electrical error) Electrical monitoring = failed [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Electrical monitoring test cycle = completed [-] A/C refrigerant distribution valve "C" communication monitoring = passed [-]        
  B3A01 Actuator control circuit open (temperature sensor error) Temperature sensor monitoring = failed [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Temperature sensor monitoring test cycle = completed [-] A/C refrigerant distribution valve "C" communication monitoring = passed [-]        
  P1A8E Wrong address Own hardware address != hardware address to be stored in the flash memory [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Wrong address monitoring test cycle = completed [-] A/C refrigerant distribution valve "C" communication monitoring = passed [-]        
  B3A03 Actuator control circuit high (over voltage) Supply voltage > 18.5 [V] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Over voltage monitoring test cycle = completed [-] A/C refrigerant distribution valve "C" communication monitoring = passed [-]        
  B3A04 Control circuit driver current/temperature too high Driver temperature > 170 [°C] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Over temperature monitoring test cycle = completed [-] A/C refrigerant distribution valve "C" communication monitoring = passed [-]        
  B3A02 Actuator control circuit low (under voltage) Supply voltage < 7.8 [V] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Under voltage monitoring test cycle = completed [-] A/C refrigerant distribution valve "C" communication monitoring = passed [-]        
  B3A17 Actuator control circuit performance (response error) Communication error = checksum error [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
      = stop bit error [-] A/C refrigerant distribution valve "C" communication monitoring = passed [-]        
    Actuator control circuit performance monitoring test cycle = completed [-]              
  B3A18 Actuator temperature range/performance (out of range high) Temperature of the A/C refrigerant distribution valve "C" > 160 [°C] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
      < 204 [°C] A/C refrigerant distribution valve "C" communication monitoring = passed [-]        
    Temperature out of range high monitoring test cycle = completed [-]              
  B3A17 Actuator control circuit performance (actuator speed) Actuator speed monitoring = failed [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Actuator speed monitoring test cycle = completed [-] A/C refrigerant distribution valve "C" communication monitoring [-]  
  B3A17 Actuator control circuit performance (actuator position) Actuator position monitoring = failed [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Actuator position monitoring test cycle = completed [-] A/C refrigerant distribution valve "C" communication monitoring [-]  
  B3A17 Actuator control circuit performance (coil holding current) Coil holding monitoring = failed [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Coil holding monitoring test cycle = completed [-] A/C refrigerant distribution valve "C" communication monitoring [-]  
  B3A17 Actuator control circuit performance (PCB temperature) PCB temperature ≥ 204 [°C] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    PCB temperature monitoring test cycle = completed [-] A/C refrigerant distribution valve "C" communication monitoring [-]  
  B3A00 Actuator stuck/open (position crosscheck) CASE 1: Delta between the actual and the target position     Ignition on > 500 [ms] continuous 100 [ms] 2 DCY
    Delta value between the actual and the target opening position of the A/C refrigerant distribution valve "C" > 4 [%] A/C refrigerant distribution valve "C" communication monitoring = passed [-]        
          A/C refrigerant distribution valve "C" electrical monitoring = passed [-]        
    CASE 2: Quick test of the actuator positioning                  
    Travel distance of the actuator of the A/C refrigerant distribution valve "C" ≥ 6 [%] Additionally for CASE 1:            
    Delta between the reference and the target position of the A/C refrigerant distribution valve "C" ≥ 19 [%] Delta value of the target position of the A/C refrigerant distribution valve "C" < 1.4 [%]        
          Time the A/C refrigerant distribution valve "C" must remain nearly in the same position > 10 [s]        
          Delta value between the reference and the target position of the A/C refrigerant distribution valve "C" > 6 [%]        
                       
          Additionally for CASE 2:            
          (Delta value of the target position of the A/C refrigerant distribution valve "C" > 19 [%]        
          OR            
          Delta value between the target and the actual opening position of the A/C refrigerant distribution valve "C") ≥ 100 [%]        
          Time the A/C refrigerant distribution valve "C" must remain nearly in the same position > 2.4 [s]        
  B3A18 Actuator temperature range/performance Temperature deviation of the internal temperature of the A/C refrigerant distribution valve "C" to the median value of the internal temperatures of the A/C refrigerant distribution valve "A", the A/C refrigerant distribution valve "B", the A/C refrigerant distribution valve "C", the A/C refrigerant distribution valve "D" and the A/C refrigerant expansion valve ≥ 18...16 [K] Ignition on > 500 [ms] continuous 100 [ms] 2 DCY
    A/C refrigerant distribution valve "A" electrical monitoring = passed [-]        
    A/C refrigerant distribution valve "B" electrical monitoring = passed [-]        
    A/C refrigerant distribution valve "C" electrical monitoring = passed [-]        
    A/C refrigerant distribution valve "D" electrical monitoring = passed [-]        
    A/C refrigerant expansion valve electrical monitoring = passed [-]        
    Debounce time for the global conditions > 4 [s]        
    Rest period of the refrigerant circuit > 360 [min]        
    Internal system operation mode = preconditioning [-]        
      OR          
      = charging/preconditioning [-]        
      OR          
      = charging [-]        
      OR          
      = ignition on [-]        
      OR          
      = ignition on/charging [-]        
      OR          
      = drive ready [-]        
      OR          
      = ignition on/preconditioning [-]        
      OR          
      = ignition on/charging/preconditioning [-]        
      OR          
      = drive ready/preconditioning [-]        
    Timer to limit the activation of the temperature crosscheck monitoring depending on the internal system operation mode < 300 [s]        
    Communication monitoring of the coolant pump "A" = passed [-]        
    Functional monitoring of the coolant pump "A" = passed [-]        
    Communication monitoring of the hybrid/EV electronics coolant pump = passed [-]        
    Functional monitoring of the hybrid/EV electronics coolant pump = passed [-]        
    Communication monitoring of the coolant pump "B" = passed [-]        
    Functional monitoring of the coolant pump "B" = passed [-]        
    Communication monitoring of the battery energy control module = passed [-]        
                 
    Cold Start Conditions            
    Debounce time for cold start conditions > 0 [s]        
    Temperature gradient of the A/C refrigerant distribution valve "A" for cold start conditions < 10 [K]        
    Temperature gradient of the A/C refrigerant distribution valve "B" for cold start conditions < 10 [K]        
    Temperature gradient of the A/C refrigerant distribution valve "C" for cold start conditions < 10 [K]        
    Temperature gradient of the A/C refrigerant distribution valve "D" for cold start conditions < 10 [K]        
    Temperature gradient of the A/C refrigerant expansion valve for cold start conditions < 10 [K]        
A/C Refrigerant Distribution Valve "D" P1A8B Incorrect component installed Current software version number != software version number stored in the data base [-] none   [-] other event n/a [-] 2 DCY
  P1A8F Wrong address (Hardware address) Stored hardware address != own hardware address [-] Plausibility check = active [-] other event n/a [-] 2 DCY
  B3A05 Actuator stuck open (blockade) Blockade monitoring = failed [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Blockade monitoring test cycle = completed [-] A/C refrigerant distribution valve "D" communication monitoring = passed [-]        
  B3A06 Actuator control circuit open (electrical error) Electrical monitoring = failed [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Electrical monitoring test cycle = completed [-] A/C refrigerant distribution valve "D" communication monitoring = passed [-]        
  B3A06 Actuator control circuit open (temperature sensor error) Temperature sensor monitoring = failed [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Temperature sensor monitoring test cycle = completed [-] A/C refrigerant distribution valve "D" communication monitoring = passed [-]        
  P1A8F Wrong address Own hardware address != hardware address to be stored in the flash memory [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Wrong address monitoring test cycle = completed [-] A/C refrigerant distribution valve "D" communication monitoring = passed [-]        
  B3A08 Actuator control circuit high (over voltage) Supply voltage > 18.5 [V] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Over voltage monitoring test cycle = completed [-] A/C refrigerant distribution valve "D" communication monitoring = passed [-]        
  B3A09 Control circuit driver current/temperature too high Driver temperature > 170 [°C] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Over temperature monitoring test cycle = completed [-] A/C refrigerant distribution valve "D" communication monitoring = passed [-]        
  B3A07 Actuator control circuit low (under voltage) Supply voltage < 7.8 [V] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Under voltage monitoring test cycle = completed [-] A/C refrigerant distribution valve "D" communication monitoring = passed [-]        
  B3A19 Actuator control circuit performance (response error) Communication error = checksum error [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
      = stop bit error [-] A/C refrigerant distribution valve "D" communication monitoring = passed [-]        
    Actuator control circuit performance monitoring test cycle = completed [-]              
  B3A1A Actuator temperature range/performance (out of range high) Temperature of the A/C refrigerant distribution valve "D" > 160 [°C] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
      < 204 [°C] A/C refrigerant distribution valve "D" communication monitoring = passed [-]        
    Temperature out of range high monitoring test cycle = completed [-]              
  B3A19 Actuator control circuit performance (actuator speed) Actuator speed monitoring = failed [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Actuator speed monitoring test cycle = completed [-] A/C refrigerant distribution valve "D" communication monitoring [-]  
  B3A19 Actuator control circuit performance (actuator position) Actuator position monitoring = failed [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Actuator position monitoring test cycle = completed [-] A/C refrigerant distribution valve "D" communication monitoring [-]  
  B3A19 Actuator control circuit performance (coil holding current) Coil holding monitoring = failed [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Coil holding monitoring test cycle = completed [-] A/C refrigerant distribution valve "D" communication monitoring [-]  
  B3A19 Actuator control circuit performance (PCB temperature) PCB temperature ≥ 204 [°C] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    PCB temperature monitoring test cycle = completed [-] A/C refrigerant distribution valve "D" communication monitoring = passed [-]  
  B3A05 Actuator stuck/open (Position crosscheck) CASE 1: Delta between the actual and the target position     Ignition on > 500 [ms] continuous 100 [ms] 2 DCY
    Delta value between the actual and the target opening position of the A/C refrigerant distribution valve "D" > 4 [%] A/C refrigerant distribution valve "D" communication monitoring = passed [-]        
          A/C refrigerant distribution valve "D" electrical monitoring = passed [-]        
    CASE 2: Quick test of the actuator positioning                  
    Travel distance of the actuator of the A/C refrigerant distribution valve "D" ≥ 6 [%] Additionally for CASE 1:            
    Delta between the reference and the target position of the A/C refrigerant distribution valve "D" ≥ 19 [%] Delta value of the target position of the A/C refrigerant distribution valve "D" < 1.4 [%]        

Table continues below

`Component / System (Official) Fault Code (SAE-Code) Monitor Strategy Description English Malfunction Criteria English Threshold Value Unit Secondary Parameters Enable Condition Unit Monitor (Frequency of Checks) Monitoring Time Length Unit MIL Illum.
            Time the A/C refrigerant distribution valve "D" must remain nearly in the same position > 10 [s]        
    Delta value between the reference and the target position of the A/C refrigerant distribution valve "D" > 6 [%]        
                 
    Additionally for CASE 2:            
    (Delta value of the target position of the A/C refrigerant distribution valve "D" > 19 [%]        
    OR            
    Delta value between the target and the actual opening position of the A/C refrigerant distribution valve "D") ≥ 100 [%]        
    Time the A/C refrigerant distribution valve "D" must remain nearly in the same position > 2.4 [s]        
  B3A1A Actuator temperature range/performance Temperature deviation of the internal temperature of the A/C refrigerant distribution valve "D" to the median value of the internal temperatures of the A/C refrigerant distribution valve "A", the A/C refrigerant distribution valve "B", the A/C refrigerant distribution valve "C", the A/C refrigerant distribution valve "D" and the A/C refrigerant expansion valve ≥ 18...16 [K] Ignition on > 500 [ms] continuous 100 [ms] 2 DCY
    A/C refrigerant distribution valve "A" electrical monitoring = passed [-]        
    A/C refrigerant distribution valve "B" electrical monitoring = passed [-]        
    A/C refrigerant distribution valve "C" electrical monitoring = passed [-]        
    A/C refrigerant distribution valve "D" electrical monitoring = passed [-]        
    A/C refrigerant expansion valve electrical monitoring = passed [-]        
    Debounce time for the global conditions > 4 [s]        
    Rest period of the refrigerant circuit > 360 [min]        
    Internal system operation mode = preconditioning [-]        
      OR          
      = charging/preconditioning [-]        
      OR          
      = charging [-]        
      OR          
      = ignition on [-]        
      OR          
      = ignition on/charging [-]        
      OR          
      = drive ready [-]        
      OR          
      = ignition on/preconditioning [-]        
      OR          
      = ignition on/charging/preconditioning [-]        
      OR          
      = drive ready/preconditioning [-]        
    (Timer to limit the activation of the temperature crosscheck monitoring depending on the internal system operation mode < 300 [s]        
                 
    Communication monitoring of the coolant pump "A" = passed [-]        
    Functional monitoring of the coolant pump "A" = passed [-]        
    Communication monitoring of the hybrid/EV electronics coolant pump = passed [-]        
    Functional monitoring of the hybrid/EV electronics coolant pump = passed [-]        
    Communication monitoring of the coolant pump "B" = passed [-]        
    Functional monitoring of the coolant pump "B" = passed [-]        
    Communication monitoring of the battery energy control module = passed [-]        
                 
    Cold Start Conditions            
    Debounce time for cold start conditions > 0 [s]        
    Temperature gradient of the A/C refrigerant distribution valve "A" for cold start conditions < 10 [K]        
    Temperature gradient of the A/C refrigerant distribution valve "B" for cold start conditions < 10 [K]        
    Temperature gradient of the A/C refrigerant distribution valve "C" for cold start conditions < 10 [K]        
    Temperature gradient of the A/C refrigerant distribution valve "D" for cold start conditions < 10 [K]        
    Temperature gradient of the A/C refrigerant expansion valve for cold start conditions < 10 [K]        
A/C refrigerant expansion valve B3A0A Actuator stuck/open (position crosscheck) Delta value between the actual and the target opening position of the A/C refrigerant expansion valve > 4 [%] Ignition on > 500 [ms] continuous 100 [ms] 2 DCY
    A/C refrigerant expansion valve communication monitoring = passed [-]        
    A/C refrigerant expansion valve electrical monitoring = passed [-]        
    Delta value of the target position of the A/C refrigerant expansion valve < 1.4 [%]        
    Time the A/C refrigerant expansion valve must remain nearly in the same position > 10 [s]        
    Delta value between the reference position and the target position > 6 [%]        
                 
                 
                 
                 
  B3A12 Actuator temperature range/performance Temperature deviation of the internal temperature of the A/C refrigerant expansion valve to the median value of the internal temperatures of the A/C refrigerant distribution valve "A", the A/C refrigerant distribution valve "B", the A/C refrigerant distribution valve "C", the A/C refrigerant distribution valve "D" and the A/C refrigerant expansion valve ≥ 18...16 [K] Switch for the A/C refrigerant expansion valve temperature range/performance monitoring with the help of the A/C refrigerant distribution valves' temperatures = TRUE [-] continuous 100 [ms] 2 DCY
    Ignition on > 500 [ms]        
    A/C refrigerant distribution valve "A" electrical monitoring = passed [-]        
    A/C refrigerant distribution valve "B" electrical monitoring = passed [ms]        
    A/C refrigerant distribution valve "C" electrical monitoring = passed [-]        
    A/C refrigerant distribution valve "D" electrical monitoring = passed [-]        
    A/C refrigerant expansion valve electrical monitoring = passed [-]        
    Debounce time for the global conditions > 4 [s]        
    Rest period of the refrigerant circuit > 360 [min]        
    Internal system operation mode = preconditioning [-]        
      OR          
      = charging/preconditioning [-]        
      OR          
      = charging [-]        
      OR          
      = ignition on [-]        
      OR          
      = ignition on/charging [-]        
      OR          
      = drive ready [-]        
      OR          
      = ignition on/preconditioning [-]        
      OR          
      = ignition on/charging/preconditioning [-]        
      OR          
      = drive ready/preconditioning [-]        
    Timer to limit the activation of the temperature crosscheck monitoring depending on the internal system operation mode < 300 [s]        
    Communication monitoring of the coolant pump "A" = passed [-]        
    Functional monitoring of the coolant pump "A" = passed [-]        
    Communication monitoring of the hybrid/EV electronics coolant pump = passed [-]        
    Functional monitoring of the hybrid/EV electronics coolant pump = passed [-]        
    Communication monitoring of the coolant pump "B" = passed [-]        
    Functional monitoring of the coolant pump "B" = passed [-]        
    Communication monitoring of the battery energy control module = passed [-]        
                 
    Cold Start Conditions            
    Debounce time for cold start conditions > 0 [s]        
    Temperature gradient of the A/C refrigerant distribution valve "A" for cold start conditions < 10 [K]        
    Temperature gradient of the A/C refrigerant distribution valve "B" for cold start conditions < 10 [K]        
    Temperature gradient of the A/C refrigerant distribution valve "C" for cold start conditions < 10 [K]        
    Temperature gradient of the A/C refrigerant distribution valve "D" for cold start conditions < 10 [K]        
    Temperature gradient of the A/C refrigerant expansion valve for cold start conditions < 10 [K]        
  B3A12 Actuator temperature range/performance Temperature deviation of the A/C pressure/temperature sensor "A" to the median value of the refrigerant temperature of the pressure/temperature sensor "A", refrigerant temperature of the pressure/temperature sensor "B", internal temperature of the pressure/temperature sensor "A", internal temperature of the pressure/temperature sensor "B" and the internal temperature of the expansion valve > 15...8 [K] Switch for the A/C refrigerant expansion valve temperature range/performance monitoring with the help of the A/C refrigerant pressure/temperature sensors' temperatures = TRUE [-] continuous 100 [ms] 2 DCY
      Ignition on > 500 [ms]        
      A/C pressure/temperature sensor "A" electrical monitoring = passed [-]        
      A/C pressure/temperature sensor "B" electrical monitoring = passed [-]        
      Expansion valve electrical monitoring = passed [-]        
      Debounce time of global conditions > 4 [s]        
      Rest period of the refrigerant circuit/vehicle off-time > 360 [min]        
      Internal system operation mode = preconditioning [-]        
        OR          
        = charging/preconditioning [-]        
        OR          
        = charging [-]        
        OR          
        = ignition on [-]        
        OR          
        = ignition on/charging [-]        
        OR          
        = drive ready [-]        
        OR          
        = ignition on/preconditioning [-]        
        OR          
        = ignition on/charging/preconditioning [-]        
        OR          
        = drive ready/preconditioning [-]        
      Time to limit the activation of the temperature crosscheck monitoring < 300 [s]        
      Communication monitoring of the coolant pump "A" = passed [-]        
      Functional monitoring of the coolant pump "A" = passed [-]        
      Communication monitoring of the hybrid/EV electronics coolant pump = passed [-]        

Table continues below

Component / System (Official) Fault Code (SAE-Code) Monitor Strategy Description English Malfunction Criteria English Threshold Value Unit Secondary Parameters Enable Condition Unit Monitor (Frequency of Checks) Monitoring Time Length Unit MIL Illum.
            Functional monitoring of the hybrid/EV electronics coolant pump = passed [-]        
    Communication monitoring of the coolant pump "B" = passed [-]        
    Functional monitoring of the coolant pump "B" = passed [-]        
    Communication monitoring of the battery energy control module = passed [-]        
                 
    Cold Start Conditions            
    Debounce time for cold start conditions > 10 [s]        
    Difference of the maximum and minimum input value of the refrigerant temperature measured at the A/C pressure/temperature sensor "A" < 10 [K]        
    Difference of the maximum and minimum input value of the refrigerant temperature measured at the A/C pressure/temperature sensor "B" < 10 [K]        
    Difference of the maximum and minimum input value of the internal temperature measured at the A/C pressure/temperature sensor "A" < 10 [K]        
    Difference of the maximum and minimum input value of the internal temperature measured at the A/C pressure/temperature sensor "B" < 10 [K]        
    Difference of the maximum and minimum input value of the internal temperature of the A/C refrigerant expansion valve < 10 [K]        
A/C refrigerant expansion valve P1BED Incorrect component installed Current software version number != software version number stored in the data base [-] none   [-] other event n/a [-] 2 DCY
  P1B8B Wrong address (hardware address) Stored hardware address != Own hardware address [-] Plausibility check = active [-] other event n/a [-] 2 DCY
  B303B Actuator control circuit open (electrical error) Electrical monitoring = failed [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Electrical monitoring test cycle = completed [-] A/C refrigerant expansion valve communication monitoring = passed [-]        
  B303B Actuator control circuit open (temperature sensor error) Temperature sensor monitoring = failed [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Temperature sensor monitoring test cylce = completed [-] A/C refrigerant expansion valve communication monitoring = passed [-]        
  B3A0A Actuator stuck open (blockade) Blockade monitoring = failed [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Blockade monitoring test cycle = completed [-] A/C refrigerant expansion valve communication monitoring = passed [-]        
  B3A0E Actuator control circuit driver current/temperature too high Driver temperature > 170 [°C] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Over temperature monitoring test cycle = completed [-] A/C refrigerant expansion valve communication monitoring = passed [-]        
  B303D Actuator control circuit high (over voltage) Supply voltage > 18.5 [V] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Over voltage monitoring test cycle = completed [-] A/C refrigerant expansion valve communication monitoring = passed [-]        
  B3A0C Actuator control circuit low (under voltage) Supply voltage < 7.8 [V] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
      Under voltage monitoring test cycle = completed [-] A/C refrigerant expansion valve communication monitoring = passed [-]        
  P1B8B Wrong address Own hardware address != hardware address to be stored in the flash memory [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Wrong address monitoring test cycle = completed [-] A/C refrigerant expansion valve communication monitoring = passed [-]        
  B3A11 Actuator control circuit performance (response error) Communication error = checksum error [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
      = stop bit error [-] A/C refrigerant expansion valve communication monitoring = passed [-]        
    Actuator control circuit performance monitoring test cycle = completed [-]              
  B3A12 Actuator temperature range/performance (out of range high) Temperature of the A/C refrigerant expansion valve > 160 [°C] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
      < 204 [°C] A/C refrigerant expansion valve communication monitoring = passed [-]        
    Temperature out of range high monitoring test cycle = completed [-]              
  B3A11 Actuator control circuit performance (actuator speed status) Actuator speed monitoring = failed [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Actuator speed monitoring test cycle = completed [-] A/C refrigerant expansion valve communication monitoring = passed [-]  
  B3A11 Actuator control circuit performance (actuator position) Actuator position monitoring = failed [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Actuator position monitoring test cycle = completed [-] A/C refrigerant expansion valve communication monitoring = passed [-]  
  B3A11 Actuator control circuit performance (coil holding current) Coil holding monitoring = failed [-] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    Coil holding monitoring test cycle = completed [-] A/C refrigerant expansion valve communication monitoring = passed [-]  
  B3A11 Actuator control circuit performance (PCB temperature) PCB temperature ≥ 204 [°C] Ignition on > 500 [ms] continuous 2.000 [ms] 2 DCY
    PCB temperature monitoring test cycle = completed [-] A/C refrigerant expansion valve communication monitoring = passed [-]  
  B3A0A Actuator stuck/open (position crosscheck) Delta value between the actual and the target opening position of the A/C refrigerant expansion valve > 4 [%] Ignition on > 500 [ms] continuous 100 [ms] 2 DCY
    A/C refrigerant expansion valve communication monitoring = passed [-]        
    A/C refrigerant expansion valve electrical monitoring = passed [-]        
    Delta value of the target position of the A/C refrigerant expansion valve < 1.4 [%]        
    Time the A/C refrigerant expansion valve must remain nearly in the same position > 10 [s]        
    Delta value between the reference position and the target position > 6 [%]        
                 
                 
                 
                 
  B3A12 Actuator temperature range/performance Temperature deviation of the internal temperature of the A/C refrigerant expansion valve to the median value of the internal temperatures of the A/C refrigerant distribution valve "A", the A/C refrigerant distribution valve "B", the A/C refrigerant distribution valve "C", the A/C refrigerant distribution valve "D" and the A/C refrigerant expansion valve ≥ 18...16 [K] Switch for the A/C refrigerant expansion valve temperature range/performance monitoring with the help of the A/C refrigerant distribution valves' temperatures = TRUE [-] continuous 100 [ms] 2 DCY
    Ignition on > 500 [ms]        
    A/C refrigerant distribution valve "A" electrical monitoring = passed [-]        
    A/C refrigerant distribution valve "B" electrical monitoring = passed [ms]        
    A/C refrigerant distribution valve "C" electrical monitoring = passed [-]        
    A/C refrigerant distribution valve "D" electrical monitoring = passed [-]        
    A/C refrigerant expansion valve electrical monitoring = passed [-]        
    Debounce time for the global conditions > 4 [s]        
    Rest period of the refrigerant circuit > 360 [min]        
    Internal system operation mode = preconditioning [-]        
      OR          
      = charging/preconditioning [-]        
      OR          
      = charging [-]        
      OR          
      = ignition on [-]        
      OR          
      = ignition on/charging [-]        
      OR          
      = drive ready [-]        
      OR          
      = ignition on/preconditioning [-]        
      OR          
      = ignition on/charging/preconditioning [-]        
      OR          
      = drive ready/preconditioning [-]        
    Timer to limit the activation of the temperature crosscheck monitoring depending on the internal system operation mode < 300 [s]        
    Communication monitoring of the coolant pump "A" = passed [-]        
    Functional monitoring of the coolant pump "A" = passed [-]        
    Communication monitoring of the hybrid/EV electronics coolant pump = passed [-]        
    Functional monitoring of the hybrid/EV electronics coolant pump = passed [-]        
    Communication monitoring of the coolant pump "B" = passed [-]        
    Functional monitoring of the coolant pump "B" = passed [s]        
    Communication monitoring of the battery energy control module = passed [-]        
                 
    Cold Start Conditions            
    Debounce time for cold start conditions > 0 [s]        
    Temperature gradient of the A/C refrigerant distribution valve "A" for cold start conditions < 10 [K]        
    Temperature gradient of the A/C refrigerant distribution valve "B" for cold start conditions < 10 [K]        
    Temperature gradient of the A/C refrigerant distribution valve "C" for cold start conditions < 10 [K]        
    Temperature gradient of the A/C refrigerant distribution valve "D" for cold start conditions < 10 [K]        
    Temperature gradient of the A/C refrigerant expansion valve for cold start conditions < 10 [K]        
  B3A12 Actuator temperature range/performance Temperature deviation of the A/C pressure/temperature sensor "A" to the median value of the refrigerant temperature of the pressure/temperature sensor "A", refrigerant temperature of the pressure/temperature sensor "B", internal temperature of the pressure/temperature sensor "A", internal temperature of the pressure/temperature sensor "B" and the internal temperature of the expansion valve > 15...8 [K] Switch for the A/C refrigerant expansion valve temperature range/performance monitoring with the help of the A/C refrigerant pressure/temperature sensors' temperatures = TRUE [-] continuous 100 [ms] 2 DCY
      Ignition on > 500 [ms]        
      A/C pressure/temperature sensor "A" electrical monitoring = passed [-]        
      A/C pressure/temperature sensor "B" electrical monitoring = passed [-]        
      Expansion valve electrical monitoring = passed [-]        
      Debounce time of global conditions > 4 [s]        
      Rest period of the refrigerant circuit/vehicle off-time > 360 [min]        
      Internal system operation mode = preconditioning [-]        
        OR          
        = charging/preconditioning [-]        
        OR          
        = charging [-]        
        OR          
        = ignition on [-]        
        OR          
        = ignition on/charging [-]        
        OR          
        = drive ready [-]        
        OR          
        = ignition on/preconditioning [-]        
        OR          
        = ignition on/charging/preconditioning [-]        
        OR          
        = drive ready/preconditioning [-]        
      Time to limit the activation of the temperature crosscheck monitoring < 300 [s]        
      Communication monitoring of the coolant pump "A" = passed [-]        
      Functional monitoring of the coolant pump "A" = passed [-]        
      Communication monitoring of the hybrid/EV electronics coolant pump = passed [-]        
      Functional monitoring of the hybrid/EV electronics coolant pump = passed [-]        
      Communication monitoring of the coolant pump "B" = passed [-]        
      Functional monitoring of the coolant pump "B" = passed [-]        
      Communication monitoring of the battery energy control module = passed [-]        
                   
      Cold Start Conditions            
      Debounce time for cold start conditions > 10 [s]        
      Difference of the maximum and minimum input value of the refrigerant temperature measured at the A/C pressure/temperature sensor "A" < 10 [K]        
      Difference of the maximum and minimum input value of the refrigerant temperature measured at the A/C pressure/temperature sensor "B" < 10 [K]        
      Difference of the maximum and minimum input value of the internal temperature measured at the A/C pressure/temperature sensor "A" < 10 [K]        

Table continues below

Component / System (Official) Fault Code (SAE-Code) Monitor Strategy Description English Malfunction Criteria English Threshold Value Unit Secondary Parameters Enable Condition Unit Monitor (Frequency of Checks) Monitoring Time Length Unit MIL Illum.
            Difference of the maximum and minimum input value of the internal temperature measured at the A/C pressure/temperature sensor "B" < 10 [K]        
    Difference of the maximum and minimum input value of the internal temperature of the A/C refrigerant expansion valve < 10 [K]        
LIN communication B1484 Automatic addressing sub bus 1 upper limit exceeded Number of answering LIN clients > configured clients [-] Valid LIN communication = commanded on [-] other event n/a [-] 2 DCY
    Auto addressing [-] 2 DCY
  B1484 Automatic addressing sub bus 1 lower limit not reached Number of answering LIN clients < configured clients [-] Valid LIN communication = commanded on [-] other event n/a [-] 2 DCY
    Auto addressing [-] 2 DCY
  U0626 Lost communication with the A/C refrigerant pressure sensor "A" (time out) No response from LIN slave for more than 4 seconds   [-] Ignition on > 500 [ms] continuous other event 4.000 [ms] 2 DCY
  U0628 Lost communication with the A/C refrigerant pressure sensor "B" (time out) No response from LIN slave for more than 4 seconds   [-] Ignition on > 500 [ms] continuous other event 4.000 [ms] 2 DCY
  U062A Lost communication with the A/C refrigerant distribution valve actuator "A" (time out) No response from LIN slave for more than 4 seconds   [-] Ignition on > 500 [ms] continuous other event 4.000 [ms] 2 DCY
  U062B Lost communication with the A/C refrigerant distribution valve actuator "B" (time out) No response from LIN slave for more than 4 seconds   [-] Ignition on > 500 [ms] continuous other event 4.000 [ms] 2 DCY
  U062C Lost communication with the A/C refrigerant distribution valve actuator "C" (time out) No response from LIN slave for more than 4 seconds   [-] Ignition on > 500 [ms] continuous other event 4.000 [ms] 2 DCY
  U062D Lost communication with the A/C refrigerant distribution valve actuator "D" (time out) No response from LIN slave for more than 4 seconds   [-] Ignition on > 500 [ms] continuous other event 4.000 [ms] 2 DCY
  U016B Lost communication with the electric A/C compressor control module (time out) Continuous: No response from the LIN slave for more than 4 seconds   [-] Ignition on > 500 [ms] continuous other event 4.000 [ms] 2 DCY
    Other event: No 0x3D-response from the LIN slave three times in a row [-]        
  U016B Lost communication with the electric A/C compressor control module (time out) Continuous: No response from LIN slave for more than 4 seconds   [-] Ignition on > 500 [ms] continuous other event 4.000 [ms] 2 DCY
    Other event: No 0x3D-response from LIN slave three times in a row [-]        
  U062E Lost communication with the A/C refrigerant expansion valve (time out) Continous: No response from LIN slave for more than 4 seconds   [-] Ignition on > 500 [ms] continuous other event 4.000 [ms] 2 DCY
    Other event: No 0x3D-response from LIN slave three times in a row [-]        
  U016B Lost communication with the electric A/C compressor (diagnosis time out) No 0x3D-response from LIN slave three times in a row   [-] Ignition on > 500 [ms] other event n/a [-] 2 DCY
  U062A Lost communication with the A/C refrigerant distribution valve actuator "A" (diagnosis time out) No 0x3D-response from LIN slave three times in a row   [-] Ignition on > 500 [ms] other event n/a [-] 2 DCY
  U062B Lost communication with the A/C refrigerant distribution valve actuator "B" (diagnosis time out) No 0x3D-response from LIN slave three times in a row   [-] Ignition on > 500 [ms] other event n/a [-] 2 DCY
  U062C Lost communication with the A/C refrigerant distribution valve actuator "C" (diagnosis time out) No 0x3D-response from LIN slave three times in a row   [-] Ignition on > 500 [ms] other event n/a [-] 2 DCY
  U062D Lost communication with the A/C refrigerant distribution valve actuator "D" (diagnosis time out) No 0x3D-response from LIN slave three times in a row   [-] Ignition on > 500 [ms] other event n/a [-] 2 DCY
  U062E Lost communication with the A/C refrigerant expansion valve actuator (diagnosis time out) No 0x3D-response from LIN slave three times in a row   [-] Ignition on > 500 [ms] other event n/a [-] 2 DCY
  U0626 Lost communication with the A/C refrigerant pressure sensor "A" (diagnosis time out) No 0x3D-response from LIN slave three times in a row   [-] Ignition on > 500 [ms] other event n/a [-] 2 DCY
  U0628 Lost communication with the A/C refrigerant pressure sensor "B" (diagnosis time out) No 0x3D-response from LIN slave three times in a row   [-] Ignition on > 500 [ms] other event n/a [-] 2 DCY
  U1030 Local data bus electrical error Sending / receiving of frames on LIN 1 = failed [-] Ignition on > 500 [ms] continuous 3.000 [ms] 2 DCY
  U1076 Local data bus 2 electrical error Sending / receiving of frames on LIN 2 = failed [-] Ignition on > 500 [ms] continuous 3.000 [ms] 2 DCY
  U10BA Local data bus no communication No response from LIN 1 slave   [-] Ignition on > 500 [ms] continuous 3.500 [ms] 2 DCY
  U10C7 Local data bus 2 no communication No response from LIN 2 slave   [-] Ignition on > 500 [ms] continuous 3.500 [ms] 2 DCY
Relay P1C41 Circuit open connection Current consumption < 40 [mA] none   [-] continuous 300 [ms] 2 DCY
  P1C42 Short circuit to ground Voltage in high-side-out measure > 1, 5 [V] Relay = commanded on [-] continuous 300 [ms] 2 DCY
  P1C43 Short circuit to battery Voltage in high-side-out = battery voltage [V] Relay = commanded off [-] continuous 300 [ms] 2 DCY
VTMC (ECU) P0604 Random Access Memory (RAM) error (2 Bit error) Checksum error   [-] none   [-] on read / write events 4.000 [ms] 1 DCY
  P0605 ROM Test Error (2 Bit error in the program flash) Checksum error   [-] none   [-] on read / write events 47.000 [ms] 1 DCY
  P0605 ROM test error (2 Bit error in the data flash) Checksum error   [-] none   [-] other event n/a [-] 1 DCY
  P0603 KAM (Keep Alive Memory) error (supply voltage measurement) Voltage difference across the polarity protection diode ≥ 1.477 [V] Voltage prior to the polarity protection diode > voltage after the polarity protection diode [V] continuous 5.000 [ms] 2 DCY
  P0603 KAM (Keep Alive Memory) error (SBC reference voltage) Reference voltage System-Basis-Chip (SBC) < 2.35 [V] SBC operating voltage ≥ 4.85 [V] continuous 5.000 [ms] 2 DCY
      OR     ≤ 16.5 [V]        
      > 2.65 [V]              
  P0562 Function restriction due to insufficient voltage Battery voltage < 8.5 [V] none   [-] continuous 5.000 [ms] 2 DCY
  P0563 Function restriction due to excessive voltage Battery voltage > 16.5 [V] none   [-] continuous 5.000 [ms] 2 DCY
  U3001 Voltage supply open circuit ECU was rebooted due to a terminal 30 reset during normal operation   [-] none   [-] startup n/a [-] 2 DCY
  P0603 KAM (Keep Alive Memory) error (sensor power supply error) Voltage < 4.56 [V] none   [-] continuous 300 [ms] 2 DCY
      OR            
      > 5.44 [V]          
  P060B A/D processing performance (temperature error) Temperature > 175 [°C] none   [-] continuous 300 [ms] 2 DCY
  P060B A/D processing performance (SPI communication error) No communication   [-]     [-] continuous 10 [ms] 2 DCY
  P060B A/D processing performance (low supply voltage error) Voltage < 3 [V]     [-] continuous 300 [ms] 2 DCY
  P060B A/D processing performance (reference clock error) Clock reference < 11 [kHz]     [-] continuous 300 [ms] 2 DCY
  P060B A/D processing performance (temperature error) Temperature > 175 [°C] none   [-] continuous 300 [ms] 2 DCY
  P060B A/D processing performance (SPI communication error) No communication   [-]     [-] continuous 10 [ms] 2 DCY
  P060B A/D processing performance (low supply voltage error) Voltage < 3 [V]     [-] continuous 300 [ms] 2 DCY
  P060B A/D processing performance (reference clock error) Clock reference < 11 [kHz]     [-] continuous 300 [ms] 2 DCY
  P060B A/D processing performance (temperature error) Temperature > 175 [°C] none   [-] continuous 300 [ms] 2 DCY
  P060B A/D processing performance (SPI communication error) No communication   [-]     [-] continuous 10 [ms] 2 DCY
  P060B A/D processing performance (low supply voltage error) Voltage < 3 [V]     [-] continuous 300 [ms] 2 DCY
  P060B A/D processing performance (reference clock error) Clock reference < 11 [kHz]     [-] continuous 300 [ms] 2 DCY
  P0603 KAM (Keep Alive Memory) error (A/D converter time out) No ADC channel conversion > 10 [ms] none   [-] continuous 150 [ms] 2 DCY
  P0603 KAM (Keep Alive Memory) error (KAM RAM read/write error) Read / write error   [-] none   [-] startup n/a [-] 1 DCY
  U1103 Production mode active Production mode = active [-] none   [-] other event n/a [-] 1 DCY
  P0604 Random Access Memory (RAM) error (time out non-volatile memory) Read time of non-volatile memory > 150 [ms] none   [-] once / DCY n/a [-] 2 DCY
Refrigerant circuit filling P10E6 Active service routine filling of refrigerant circuit Service routine filling of refrigerant circuit commanded = On [-] none   [-] continuous 500 [ms] 2 DCY
Service routine purging refrigerant circuit P10E7 Commanded service routine purging of refrigerant circuit Purging refrigerant circuit service routine commanded = on [-] none   [-] continuous 500 [ms] 2 DCY
Hybrid/EV Electronics Cooling System Performance P2C72 Cooling system performance monitoring CASE 1: Temperature Gradient     Ignition on > 500 [ms] continuous 100 [ms] 2 DCY
    Delta temperature gradient > 1.6...2.5 [K/s] Drive motor control module "A" communication monitoring = passed [-]        
    (For detailed information about the "delta temperature gradient" please refer to the Technical Description)     Battery energy control module "B" communication monitoring = passed [-]        
    CASE 2: Inverter module temperature     Cooling fans communication and functional monitoring = passed [-]        
    Quotient from actual and stored inverter module temperature > 1.3...1.3 [%] Hybrid/EV electronics pump communication and functional monitoring = passed [-]        
    (For detailed information about the "energy of the inverter" please refer to the Technical Description)     Hybrid/EV electronics coolant temperature sensor "C" electrical monitoring = passed [-]        
          Active grille air shutter communication monitoring = passed [-]        
          Active grille air shutter electrical monitoring = passed [-]        
          Duty cycle of the hybrid/EV electronics pump > 20 [%]        
          Time for the temperature homogenization in the electromachine circuit > 60 [s]        
          Debounce time for the calculation of delta temperature gradient > 10 [s]        
          Actual position of the active grille air shutter > 50 [%]        
          Additionally for CASE 1            
          Energy conversion of the inverter module in the electromachine circuit > 250 [kWs]        
          Additionally for CASE 2            
          Temperature difference between the inverter module and the coolant > 5 [K]        
          Energy conversion of the inverter module within a defined range < 300 [kWs]        
            > 200.1 [kWs]        
          Continuity of the coolant temperature ≤ 5 [K]        
          Cooling time depending on the ambient temperature and the vehicle speed > 6553...30 [s]        
Hybrid/EV Battery Cooling System Performance P0C32 Insufficient cooling in the low temperature circuit Coolant temperature difference between the stored and the actual temperature value measured with the hybrid/EV battery pack coolant temperature sensor "B" < - 3 [K] (Ignition on > 500 [ms] continuous 100 [ms] 2 DCY
    OR     OR            
    Temperature difference between the actual temperature value measured with the hybrid/EV battery pack coolant temperature sensor "B" and the set temperature of the hybrid/EV battery pack coolant temperature sensor "B" requested by the BMS > 2 [K] Cabin preconditioning (immediate conditioning or programmed conditioning)) > 500 [ms]        
          A/C pressure/temperature sensor "A" electrical monitoring = passed [-]        
          A/C pressure/temperature sensor "B electrical monitoring = passed [-]        
          Hybrid/EV battery pack coolant temperature sensor "A" electrical monitoring = passed [-]        
          Hybrid/EV battery pack coolant temperature sensor "B" electrical monitoring = passed [-]        
          Hybrid/EV battery pack coolant control valve "A" electrical monitoring = passed [-]        
          Cooling fan 1 communication and functional monitoring = passed [-]        
          Cooling fan 2 communication and functional monitoring = passed [-]        
          A/C refrigerant distribution valve "A electrical monitoring = passed [-]        
          A/C refrigerant distribution valve "B" electrical monitoring = passed [-]        
          A/C refrigerant distribution valve "C" electrical monitoring = passed [-]        
          A/C refrigerant distribution valve "D" electrical monitoring = passed [-]        
          A/C refrigerant expansion valve electrical monitoring = passed [-]        
          Electric A/C compressor electrical monitoring = passed [-]        
          Battery energy control module "B" communication monitoring = passed [-]        
          Available energy of the high-voltage battery > 500 [Wh]        
          [(Revolution speed of the combustion engine < 400 [rpm]        
          OR            
          Temperature of combustion engine out) < 113 [°C]        
          OR            
          (Revolution speed of the combustion engine > 400 [rpm]        
          AND   [-]        
          Temperature of combustion engine out) > 113 [°C]        
            < 117 [°C]        
          No electric A/C compressor intervention request from the engine control module to the VTMC   [-]        
          Duty cycle of the hybrid/EV battery pack coolant pump in the battery circuit > 30 [%]        
          System configuration of the refrigerant circuit for hybrid/EV battery cooling system performance = active battery cooling [-]        
            OR          
            = active battery and passenger compartment cooling [-]        
          Actual opening position of the A/C refrigerant expansion valve ≥ 5 [%]        
          Electric A/C compressor = enabled [-]        
          Cooling timer > 180 [s]        
A/C system pressure too high B3A1B High pressure monitoring in active battery cooling mode CASE 1: High pressure short events     Ignition on > 500 [ms} continuous 100 [ms] 2 DCY
    A/C compressor controller counter for high pressure short events > 15 [-] A/C refrigerant pressure/temperature sensor "A" electrical monitoring = passed [-]        
    OR     System configuration for high pressure monitoring in active battery cooling mode = active battery cooling [-]        
    A/C compressor protective reaction counter for high pressure short events > 5 [-]   OR          
            = active battery and passenger compartment cooling [-]        
    CASE 2: High pressure long event     Cooling fans 1/2 communication and functional monitoring = passed [-]        
    A/C compressor controller debounce time for high pressure long event > 90 [s] Active grille air shutter electrical monitoring = passed [-]        
    OR                  
    A/C compressor protective reaction debounce time for high pressure long event > 90 [s] High Pressure Event            
          Status of the A/C compressor protective reaction = high pressure event [-]        
          OR            
          Status of the electric A/C compressor controller = high pressure control [-]        
                       
          A/C Compressor Protective Reaction = High pressure event            
          Pressure measured with the A/C refrigerant pressure/temperature sensor "A" > 31 [bar]        
          OR            
          (Pressure measured with the A/C refrigerant pressure/temperature sensor "A" > 23 bar [bar]        
          AND            
          Status of the A/C compressor) = evaporator icing [-]        
            OR          
            = hot gas event          
          OR            

Table continues below

Component / System (Official) Fault Code (SAE-Code) Monitor Strategy Description English Malfunction Criteria English Threshold Value Unit Secondary Parameters Enable Condition Unit Monitor (Frequency of Checks) Monitoring Time Length Unit MIL Illum.
            (Status of the A/C compressor protective reaction = high pressure event [-]        
    AND            
    Pressure measured with the A/C refrigerant pressure/temperature sensor "A") > 23 [bar]        
                 
    Additionally for CASE 1            
    Revolution speed of the A/C compressor < 800 [rpm]        
                 
    Additionally for CASE 2            
    Revolution speed of the A/C compressor < 800 [rpm]        
    OR            
    Vehicle speed > 50 [km/h]        
A/C refrigerant charge loss P0534 Low pressure monitoring in active battery cooling mode CASE 1: Low pressure short events     Ignition on > 500 [ms] continuous 100 [ms] 2 DCY
    A/C compressor controller counter for low pressure short events > 15 [-] A/C refrigerant pressure/temperature sensor "B" electrical monitoring = passed [-]        
    OR     Status of the ambient temperature = valid [-]        
    A/C compressor protective reaction counter for low pressure short events > 5 [-] A/C refrigerant pressure/temperature sensor "A" electrical monitoring = passed [-]        
          Body control module monitoring = passed [-]        
    CASE 2: Low pressure long event     Expansion valve electrical monitoring = passed [-]        
    A/C compressor controller debounce time for low pressure long event > 35 [s] Hybrid/EV battery pack coolant temperature sensor "B" electrical monitoring = passed [-]        
    OR     A/C compressor electrical monitoring = passed [-]        
    A/C compressor protective reaction debounce time for low pressure long event > 15 [s] Temperature measured with the hybrid/EV battery pack coolant temperature sensor "B" > 10 [°C]        
          System configuration for low pressure monitoring = active battery cooling [-]        
            OR          
            = active battery and passenger compartment cooling [-]        
          Actual revolution speed of the A/C compressor ≥ 700 [rpm]        
          Battery energy control module "B" communication monitoring = passed [-]        
                       
          Low Pressure Event            
          Status of the A/C compressor controller = low pressure control [-]        
          OR            
          Status of the A/C compressor protective reaction = low pressure event [-]        
                       
          A/C Compressor Protective Reaction = Low pressure event            
          Pressure measured with the A/C refrigerant pressure/temperature sensor "B" < 0.90625...0.90625 [bar]        
          OR            
          (Pressure measured with the A/C refrigerant pressure/temperature sensor "B" < 1... 1 [bar]        
          AND            
          Debounce time for the A/C compressor emergency stop because of low pressure) > 15 [s]        
          OR            
          (Status of the A/C compressor protective reaction = low pressure event [-]        
          AND            
          Pressure measured with the A/C refrigerant pressure/temperature sensor "B") < 1.09375... 1.09375 [bar]        
          OR            
          Pressure measured with the A/C refrigerant pressure/temperature sensor "A" < 0.59375... 6.796875 [bar]        
                       
          Additionally for CASE 1            
          Actual revolution speed of the A/C compressor < 700 [rpm]        
                       
          Additionally for CASE 2            
          Actual revolution speed of the A/C compressor < 700 [rpm]        
          Refrigerant pressure measured with the A/C refrigerant pressure/temperature sensor "B" < 3 [bar]        
A/C system temperature too high B3A1C Hot gas temperature upper limit exceeded CASE 1: Hot gas short events     Ignition on > 500 [ms] continuous 100 [ms] 2 DCY
    Counter for hot gas short events ≥ 15 [-] A/C pressure/temperature sensor "A" electrical monitoring = passed [-]        
          System configuration of the refrigerant circuit for hot gas monitoring = passenger compartment heating [-]        
    CASE 2: Hot gas long event       OR          
    Debounce time for hot gas long event > 30 [s]   = passenger compartment cooling [-]        
            OR          
            = active battery cooling [-]        
            OR          
            = active battery and passenger compartment cooling [-]        
            OR          
            = passenger compartment dehumidifying [-]        
            OR          
            = routine for A/C compressor start-up [-]        
          (Vehicle speed > 50 [km/h]        
          Debounce time for activating hot gas fail monitoring > 30 [s]        
          System configuration of the cooling fans for hot gas monitoring) = passenger compartment cooling [-]        
            OR          
            = active battery cooling [-]        
            OR          
            = active battery and passenger compartment cooling [-]        
          OR            
          (Vehicle speed ≤ 50 [km/h]        
          System configuration of the cooling fans for hot gas monitoring) != passenger compartment cooling [-]        
            AND          
            != active battery cooling [-]        
            AND          
            != active battery and passenger compartment cooling [-]        
          Revolution speed of the A/C compressor < 800 [rpm]        
          (Status of the electric A/C compressor controller = hot gas control [-]        
          OR            
          Status of the electric A/C compressor protective reaction) = hot gas event [-]        
                       
          Protective Reaction of the A/C compressor = Hot Gas Event            
          Temperature measured with the A/C refrigerant pressure/temperature sensor "A" > 145 [°C]        
          OR            
          (Electric A/C compressor protective reaction = hot gas event          
          Temperature measured with the A/C refrigerant pressure/temperature sensor "A") > 135 [°C]        
              [-]        
          Additionally for CASE 1:            
          (Cooling fans communication and functional monitoring = passed [-]        
          Active grille air shutter electrical monitoring) = passed          
          OR   [-]        
          Auxiliary heater control module communication monitoring = passed          
              [-]        
          Additionally for CASE 1:            
          Actual revolution speed of the A/C compressor for monitoring of long events < 800 [rpm]        
                         

DAB 11-23-20