Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Audi >> 2017 >> S3 Premium Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 133 (Generic Scan Tool 2.0L (CNTC) - Engine DTC Tables) >> St Generic Scan Tool >> Diagnosis And Testing >> Engine DTC Tables >> Engine Control Module --, 2016 MY

Engine Control Module --, 2016 MY

WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2017 Audi A3 Quattro, 2017 Audi A3, 2016 Audi A3 Quattro, 2016 Audi A3, and 2015 Audi A3 Quattro. However, it is still accessible from the selected car via links, so may be relevant.
DTC / Description Monitor Strategy Description Malfunction Criteria and Threshold Value Secondary Parameters with Enable Conditions Monitoring Time Length MIL Illum. Component Diagnostic Procedure
P000A  "A" Camshaft Position Slow Response Bank 1 VVT Actuator Intake Rationality Check
  • Adjustment angle difference >= 1.00; < 10.0° CRK
  • Modeled oil temperature -40 - 160° C
  • Engine speed 608 - 6, 016 RPM
  • Set point change > 20.0° CRK
  • Dynamic diagnosis timer >= 0.95 - 4.0 s
  • 0 FTP75: 300 s
  • Continuous
  • 2 DCY
-- Check the Camshaft Adjustment Valve 1 -N205-. Refer to Camshaft Adjustment Valve 1 -N205-, CHECKING .
P000B  "B" Camshaft Position Slow Response Bank 1 Variable Valve Timing (VVT) Exhaust Actuator rationality check
  • Adjustment angle difference>= 1.00; < 3.50° CRK
  • Modeled oil temperature -40 - 160° C
  • Engine speed 608 - 6, 016 RPM
  • Set point change > 6.0° CRK
  • Dynamic diagnosis timer >= 0.95 - 4.0 s
  • 0 FTP75: 700 s
  • Continuous
  • 2 DCY
-- Check the Exhaust Camshaft Adjustment Valve 1 -N318-. Refer to Exhaust Camshaft Adjustment Valve 1 -N318-, CHECKING
P0010 "A" Camshaft Position Actuator Control Circuit/Open Bank 1 VVT Actuator Intake Open Circuit
  • Output voltage lower range 1.92 - 2.21 V
  • Output voltage upper range (hardware values) 2.85 - 3.25 V
  • Actuator commanded off
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the Camshaft Adjustment Valve 1 -N205-. Refer to Camshaft Adjustment Valve 1 -N205-, CHECKING .
P0011  "A" Camshaft Position - Timing Over-Advanced or System Performance Bank 1 VVT Actuator Intake Rationality Check
  • Camshaft position deviation > 10.0° CRK
  • Modeled oil temperature -40 - 160° C
  • Engine speed 608 - 6, 016 RPM
  • Camshaft position n.a.
  • Camshaft position adjustment active
  • Catalyst heating not active
  • Camshaft position deviation integrator (actual vs. setpoint position) >= 9.00 - 12.00° CRK
  • 0 FTP75: 250 s
  • Continuous
  • 2 DCY
-- Check the Camshaft Adjustment Valve 1 -N205-. Refer to Camshaft Adjustment Valve 1 -N205-, CHECKING .
P0013 "B" Camshaft Position Actuator Control Circuit/Open Bank 1 Variable Valve Timing (VVT) Exhaust Actuator open circuit
  • Output voltage, lower range1.92 - 2.21 V
  • Output voltage, upper range2.85 - 3.25 V (hardware values)
  • Actuator commanded off
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the Exhaust Camshaft Adjustment Valve 1 -N318-. Refer to Exhaust Camshaft Adjustment Valve 1 -N318-, CHECKING
P0014  "B" Camshaft Position - Timing Over-Advanced or System Performance Bank 1 Variable Valve Timing (VVT) Exhaust Actuator Rationality Check
  • Difference between target and actual position> 10.00° CRK
  • Modeled oil temperature -40 - 160° C
  • Engine speed 608 - 6, 016 RPM
  • Camshaft position n.a.
  • Camshaft position adjustment active
  • Catalyst heating not active
  • Camshaft position deviation integrator (actual vs. setpoint position) >= 9.00 - 12.00° CRK
  • 0 FTP75: 450 s
  • Continuous
  • 2 DCY
-- Check the Exhaust Camshaft Adjustment Valve 1 -N318-. Refer to Exhaust Camshaft Adjustment Valve 1 -N318-, CHECKING
P0016 Crankshaft Position - Camshaft Position Correlation Bank 1 Sensor A Camshaft Position/Crankshaft Position Intake - Correlation Adaptation Value Monitoring
  • Adapted value for each edge of the target wheel < -14.0° CRK
  • Or
  • Adapted value for each edge of the target wheel > 14.0° CRK
  • Camshaft position adaptation active
  • (Exhaust side)
  • Engine speed 288 - 4, 000 rpm
  • Modeled oil temperature >= -15° C
  • Modeled oil temperature <= 160° C
  • Diff. actual exhaust camshaft position vs. previous camshaft position @ reference signal edge < 2.00° CRK
  • And
  • Case 1:
  • Ignition off
  • Engine speed > 380 rpm
  • Engine stalling >= 1.0 s
  • Or
  • Case 2:
  • Engine speed >= 380 rpm
  • Or
  • Engine running
  • Engine stalling>= 5.0s
  • Or
  • Case 3:
  • Backwards rotationnot detected
  • Or
  • Case 4:
  • Engine speed>= 400rpm
  • Enginestopped
  • 720° CRK
  • Multiple
  • 2 DCY
-- Check the Camshaft Adjustment Valve 1 -N205-. Refer to Camshaft Adjustment Valve 1 -N205-, CHECKING .-- Check the Engine Speed Sensor -G28-. Refer to Engine Speed Sensor -G28-, CHECKING .
  • Diff. actual camshaft adaptation per cylinder vs. previous reference camshaft adaptation >= 12.00° CRK
General:
  • Camshaft phasing commanded
  • Engine speed < 8, 160 rpm
  • Diff. actual intake camshaft position vs. previous camshaft position @ reference signal edge < 2.00° CRK
  • Case 1:
  • Ignition off
  • Engine speed > 380 RPM
  • Engine stalling >= 1.0 s
  • Case 2:
  • synchronization test incorrect
  • Or
  • Engine running
  • And
  • Engine stalling >= 5.0 s
  • Case 3:
  • Backwards rotation not detected
  • Or
  • Case 4:
  • Engine speed >= 400 RPM
  • Engine stopped
  • 0.1 s
  • Continuous
P0017 Crankshaft Position - Camshaft Position Correlation Bank 1 Sensor B Camshaft Position/Crankshaft Position Exhaust - Correlation Adaptation Value Monitoring
  • Adapted value for each edge of the target wheel < -14.0° CRK
  • Or
  • Adapted value for each edge of the target wheel > 14.0° CRK
  • Camshaft position adaptation active
  • (Exhaust side)
  • Modeled oil temperature >= -15° C
  • Modeled oil temperature <= 160° C
  • Engine speed 288 - 4, 000 RPM
  • Diff. actual exhaust camshaft position vs. previous camshaft position @ reference signal edge < 2.0° CRK
  • And
  • Case 1:
  • Ignition off
  • Engine speed > 380 RPM
  • Engine stalling >= 1.0 s
  • Or
  • Case 2:
  • Engine speed >= 380 RPM
  • Or
  • Engine running
  • And
  • Engine stalling >= 5.0 s
  • Or
  • Case 3:
  • Backwards rotation not detected
  • Or
  • Case 4:
  • Engine speed >= 400 RPM
  • Engine stopped
  • 720° CRK
  • Multiple
  • 2 DCY
-- Check the Exhaust Camshaft Adjustment Valve 1 -N318-. Refer to Exhaust Camshaft Adjustment Valve 1 -N318-, CHECKING -- Check the Engine Speed Sensor -G28-. Refer to Engine Speed Sensor -G28-, CHECKING .
P0030 HO2S Heater Control Circuit Bank 1 Sensor 1 Oxygen Sensors Heater Front Open Circuit
  • O2S upstream heater voltage lower range 1.92 - 2.21 V
  • O2S downstream heater voltage upper range 2.85 - 3.25 V
 
  • 2.5 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter -GX10-, CHECKING .
P0031 HO2S Heater Control Circuit Low Bank 1 Sensor 1 Oxygen Sensors Heater Front Short To Ground
  • O2S upstream heater voltage lower range 1.92 - 2.21 V
 
  • 2.5 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter -GX10-, CHECKING .
P0032 HO2S Heater Control Circuit High Bank 1 Sensor 1 Oxygen Sensors Heater Front Short To Battery Voltage
  • O2S upstream heater driver temperature > 160.0 - 200.0° C
  • Or
  • O2S upstream heater driver output current driver stage internal value
  • EGT @ O2S front >= -273° C
  • Actuator commanded on
  • 2.5 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter -GX10-, CHECKING .
P0033 Turbocharger/Supercharger Bypass Valve "A" Control Circuit Turbocharger Bypass (TCBY) open circuit
  • Voltage, lower range1.92 - 2.21V
  • Voltage, upper range2.85 - 3.25V (hardware values)
  • Actuatorcommanded off
  • 1.0 s
  • Continuous
  • 2 DCY
-- Check the Turbocharger Recirculation Valve -N249-. Refer to Turbocharger Recirculation Valve -N249-, CHECKING
Turbocharger Bypass (TCBY) short to battery plus
  • Currentdriver stage internal value
  • Or
  • Temperature> 160 - 200° C (hardware values)
  • Actuatorcommanded on
P0034 Turbocharger/Supercharger Bypass Valve "A" Control Circuit Low Turbocharger Bypass (TCBY) short to ground
  • Voltage< 1.92 - 2.21V (hardware values)
  • Actuatorcommanded off
  • 1.0 s
  • Continuous
  • 2 DCY
-- Check the Turbocharger Recirculation Valve -N249-. Refer to Turbocharger Recirculation Valve -N249-, CHECKING
P0036 HO2S Heater Control Circuit Bank 1 Sensor 2 Oxygen Sensors Heater Rear Open Circuit
  • O2S downstream heater voltage lower range 1.92 - 2.21 V
  • O2S downstream heater voltage upper range 2.85 - 3.25 V
  • Engine not in start process
  • 2.5 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter -GX7-, CHECKING .
P0037 HO2S Heater Control Circuit Low Bank 1 Sensor 2 Oxygen Sensors Heater Rear Short To Ground
  • O2S downstream heater voltage 1.92 - 2.21 V
  • Engine not in start process
  • 2.5 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter -GX7-, CHECKING .
P0038 HO2S Heater Control Circuit High Bank 1 Sensor 2 Oxygen Sensors Heater Rear Short To Battery Voltage
  • O2S downstream heater driver temperature > 160.0 - 200.0° C
  • Or
  • O2S downstream heater driver output current driver stage internal value
  • EGT @ O2S rear (binary) >= -273
  • Actuator commanded on
  • Engine not in start process
  • 2.5 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter -GX7-, CHECKING .
P0045 Turbocharger/Supercharger Boost Control "A" Circuit/Open Turbocharger Boost Pressure Control Valve Open Circuit
  • Bypass valve driver load resistance > 200 kOhm
  • Deviation between actual and filtered boost pressure actuator position <= 5.0 %
  • Boost pressure actuator controller not active
  • Time delay > 1.0 s
  • 0.4 s
  • Continuous
  • 2 DCY
-- Check the Charge Pressure Actuator -V465- / Charge Pressure Actuator Position Sensor -G581-. Refer to Charge Pressure Actuator -V465- / Charge Pressure Actuator Position Sensor -G581-, CHECKING .
P0068 MAP/MAF - Throttle Position Correlation Leak to Intake Manifold Rationality Check
  • Difference between target intake manifold pressure and actual intake manifold pressure < -15.0 - -10.0 kPa
  • Time after engine start > 5.0 s
  • Barometric pressure > 73.0 - 105.0 kPa
  • Engine speed > 576 - 512 RPM
  • Engine speed < 3, 000 RPM
  • IAT @ intake manifold > -48° C
  • ECT @ cylinder head > -48° C
  • Difference between engine speed and filtered engine speed < 8, 160 RPM
  • Diff. air mass setpoint vs. filtered air mass setpoint for load dynamic detection< 25.01 mg/rev
  • Throttle actuator commanded on
  • Modeled pressure quotient 0.10 - 0.60 [-]
  • Gradient of intake manifold pressure >= -199.90; <= 199.90 kPa/s
  • Vehicle speed <= 1 mph
  • 5.0 s
  • Continuous
  • 2 DCY
-- Check the Intake system for vacuum leaks, make sure oil dipstick is pushed properly into place.-- Check the Intake Manifold Sensor -GX9-. Refer to Intake Manifold Sensor -GX9-, CHECKING .-- Check the Throttle Valve Control Module -GX3-. Refer to Throttle Valve Control Module -GX3-, CHECKING .
Intake Air System Rationality Check
  • General conditions:
  • Filtered lambda controller included correction and adaption -30.00 - 30.00 %
  • Lambda control active
  • And
  • Deviation throttle area controller < -60.00 %
General conditions:
  • Throttle position> 0.000° TPS
  • Throttle position< 100.003° TPS
  • Engine speed> 576; < 3008rpm
  • Modeled pressure quotient> 0.27; < 0.57[-]
  • Enginerunning
  • Throttle actuatorcommanded on
  • Time after engine start> 5.0 s
  • Throttle positionsensor failure not detected
  • Fuel cut offnot active
  • Fast throttle adaptationfinished
  • MAP gradient-199.90 - 199.90 kPa/s
  • BARO plausibility diagnosisfinished
  • Intake manifold modeled adaptation active
  • And
  • Choice of:
  • MAF sensoractive
  • Or
  • MAP sensor active
  • And
  • Choice of:
  • Pressure upstream throttle< 135.00kPa
  • Or
  • Pressure upstream throttlenot active
  • And
  • Choice of:
  • BARO> 73.00; < 107.50 kPa
  • Or
  • Barometric pressure sensor not active
P0070 Ambient Air Temperature Sensor Circuit "A" CAN: Ambient Air Temperature Sensor Short To Battery Voltage Or Open Circuit
  • AAT sensor voltage (hardware values) > 4.50 V
 
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the Outside Air Temperature Sensor -G17-. Refer to Outside Air Temperature Sensor -G17-, CHECKING .
P0071 Ambient Air Temperature Sensor Circuit "A" Range/Performance Ambient Air Temperature Sensor Cross Check
  • High side:
  • Diff. AAT @ cold start vs. IAT @ manifold @ cold start > 25 K
  • Diff. AAT @ cold start vs. ECT @ radiator outlet @ cold start > 25 K
  • Min. amount of faulty reference measurements to detect defective sensor 2.00 [-]
  • Or
  • Low side:
  • Diff. IAT @ manifold @ cold start vs. AAT @ cold start > 25.0 K
  • Diff. ECT @ radiator outlet @ cold start vs. AAT @ cold start > 25.0 K
  • Min. amount of faulty reference measurements to detect defective sensor 2.00 [-]
  • Engine off time >= 360.0 min
  • Engine off time plausible
  • Time after engine start < 1, 400.0 s
  • Depending on temperature slope:
  • Diff. actual vs previous IAT < 256.0 K
  • Diff. actual vs previous ECT @ cylinder head n.a. K
  • Diff.. actual vs previous ECT@ radiator outlet < 256.0 K
  • Diff. actual vs previous AAT < 256.0 K
  • For time >= 1.0 s
  • Depending on meanvalue condition
  • Mean value of all temperature sensors @ cold start>= -256° C
  • Number of valid sensors>= 2.00[-]
  • Depending on block heater / solar radiation detection
  • Time after engine start>= 0.5s
  • Vehicle speed>= 22 mph
  • For time>= 20.0 s
  • Diff. actual IAT @ manifold vs. min. IAT @ manifold< 5.0 K
  • Diff. actual ECT @ cylinder head vs. min. ECT @ cylinder headn.a.K
  • Diff. actual AAT vs. min. AAT< 4.0 K
  • Diff. actual ECT @ radiator outlet vs. min. ECT @ radiator outlet< 1.1 K
  • 0.1 s
  • Once / DCY
  • 2 DCY
-- Check the Outside Air Temperature Sensor -G17-. Refer to Outside Air Temperature Sensor -G17-, CHECKING .
P0072 Ambient Air Temperature Sensor Circuit "A" Low CAN: Ambient Air Temperature Sensor Short To Ground
  • AAT sensor voltage < 0.10 V
 
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the Outside Air Temperature Sensor -G17-. Refer to Outside Air Temperature Sensor -G17-, CHECKING .
P0087 Fuel Rail/System Pressure - Too Low Bank 1 Fuel System Pressure Sensor, High Pressure Side Out Of Range Low
  • Deviation lambda of controller included adaptation -50.0 - 50.0 %
  • And
  • High pressure controller output > 45 mg
  • And
  • Deviation between fuel pressure set point and current fuel pressure > 2, 999.80 kPa
  • Fuel pressure > 3, 500.31 kPa
General:
  • Engine speed608 - 6, 816[rpm]
  • Fuel mass setpoint5.00 - 1, 389.00mg/rev
  • Time after engine start> 10.0 s
  • Engine warm-upnot calibrated
  • Catalyst heatingnot calibrated
  • Full loadnot calibrated
  • Catalyst purgenot calibrated
  • Lambda controlnot calibrated
  • Evap purge functionality diagnosisnot calibrated
  • Fuel pressure setpoint gradient<= 34, 777.60kPa
  • And
  • Depending on low dynamic conditions:
  • Fuel mass setpoint lower range> 5.00mg/rev
  • For time >= 10.0 s
  • Fuel mass setpoint upper range< 187.17 - 229.23mg/rev
  • Fuel mass setpoint gradient-1389.00 - 1389.00mg/rev
  • For time>= 5.0s
  • And
  • Depending on canister purge:
  • Canister loadnot calibrated[-]
  • Or
  • Evap purge valve not calibrated
  • 5.0 s
  • Continuous
  • 2 DCY
-- Check the fuel pressure, refer to the repair information for proper procedures.-- Check the Fuel Pressure Sensor -G247-. Refer to Fuel Pressure Sensor -G247-, CHECKING .-- Check the Fuel Pressure Regulator Valve -N276-. Refer to Fuel Pressure Regulator Valve -N276-, CHECKING .-- Check the Fuel Pump Control Module -J538- / Fuel Delivery Unit -GX1-. Refer to Fuel Pump Control Module -J538- /Fuel Delivery Unit -GX1-, CHECKING .
P0090 Fuel Pressure Regulator 1 Control Circuit/Open Fuel Volume Regulator Control open circuit
  • Voltage high side< 1.87 - 2.26V
  • Voltage low side> 2.78 - 3.33V
  • Engine speed> 600 rpm
  • And
  • Fuel cut offnot active
  • Actuator commanded on
  • 0.8 s
  • Continuous
  • 2 DCY
-- Check the Fuel Pressure Regulator Valve -N276-. Refer to Fuel Pressure Regulator Valve -N276-, CHECKING .
  • Low and high side Off:
  • Voltage low side> 2.78 - 3.33V
  • Voltage high side< 1.87 - 2.26V
  • Low and high side On:
  • Current low sidedriver stage internal value
  • Current high sidedriver stage internal value
P0091 Fuel Pressure Regulator 1 Control Circuit Low Fuel Volume Regulator Control short to ground (high side)
  • Current high sidedriver stage internal value (hardware values)
  • Ignitionon
  • Or
  • Ignitionoff (during ECM keep alive-time)
  • And
  • Actuatorcommanded on
  • 0.8 s
  • Continuous
  • 2 DCY
-- Check the Fuel Pressure Regulator Valve -N276-. Refer to Fuel Pressure Regulator Valve -N276-, CHECKING .
Fuel Volume Regulator Control short to ground (low side)
  • Voltage low side< 1.87 - 2.26V (hardware values)
  • Ignitionon
  • Or
  • Ignitionoff (during ECM keep alive-time)
  • And
  • Actuatorcommanded off
P0092 Fuel Pressure Regulator 1 Control Circuit High Fuel Control Valve Short To Battery Plus (Low Side)
  • Current low side (hardware values) driver stage internal value
  • Ignition on
  • Or
  • Ignition off (during ECM keep alive-time)
  • And
  • Actuator commanded on
  • 0.8 s
  • Continuous
  • 2 DCY
-- Check the Fuel Pressure Regulator Valve -N276-. Refer to Fuel Pressure Regulator Valve -N276-, CHECKING .
Fuel Control Valve Short To Battery Plus (High Side)
  • Voltage high side (hardware values) < 2.78 - 3.33 V
  • Ignition on
  • Or
  • Ignition off (during ECM keep alive-time)
  • And
  • Actuator commanded off
P00B7 Engine Coolant Flow Low/Performance Rotary Coolant Valve Functional Check
  • Diff. previous and actual position of RVC < 4.0°
  • ECT @ cylinder head > 11° C
  • RCV position 0.00 - 270.0°
  • Diff. previous actual and target position of RCV > 5.0°
  • And
  • RCV adaptation finished
  • Or
  • RCV adaptation not active
  • 3.0 s
  • Continuous
  • 2 DCY
-- Check coolant system for leaks or damage.-- Check the Engine Temperature Control Actuator -N493-. Refer to Engine Temperature Control Actuator -N493-, CHECKING ..
P0106 Manifold Absolute Pressure/Barometric Pressure Sensor Circuit Range/Performance Manifold Pressure Sensor By Engine Standing: Rationality Check During ECM Keep Alive-Time:
  • Case 1:
  • Diff. barometric pressure vs. intake manifold pressure>= 8.50 kPa
  • Diff. upstream throttle pressure vs. intake manifold pressure> 8.50 kPa
  • Diff. barometric pressure vs. upstream throttle pressure< 8.50 kPa
  • Case 2:
  • Intake manifold pressure (raw value)< 25.00; > 125.00kPa
  • Case 3;
  • Diff. barometric pressure vs. intake manifold pressuren.a. kPa
  • Diff. upstream throttle pressure vs. intake manifold pressuren.a. kPa
  • Diff. barometric pressure vs. upstream throttle pressuren.a.kPa
  • Diff. intake manifold pressure vs. intake manifold pressure @ idle or low part loadn.a.kPa
  • Case 4:
  • Diff. barometric pressure vs. intake manifold pressuren.a. kPa
  • Diff. upstream throttle pressure vs. intake manifold pressuren.a. kPa
  • Diff. barometric pressure vs. upstream throttle pressuren.a. kPa
  • Diff. intake manifold pressure vs. intake manifold pressure @ idle or low part loadn.a. kPa
  • Enginestopped
  • Ignitionoff
  • Vehicle speed< 1 mph
  • ECM keep alive time> 10.0 s
  • Delay time after engine stop>= 5.0 s
  • Barometric pressure sensor voltage0.20 - 4.80 V
  • MAP sensor voltage0.20 - 4.80 V
  • Turbocharger boost pressure sensor voltage0.20 - 4.80 V
  • 3.0 s
  • Once / DCY
  • 2 DCY
-- Check the Intake Manifold Sensor -GX9-. Refer to Intake Manifold Sensor -GX9-, CHECKING .
Intake Air System Rationality Check
  • General conditions:
  • Filtered lambda controller included correction and adaption < -30.0 %
  • And
  • Deviation throttle area controller > 45.0 %
  • Throttle position > 0.0° TPS
  • Throttle position < 100.003° TPS
  • Engine speed > 576; < 3008 RPM
  • Modeled pressure quotient > 0.27; < 0.57 [-]
  • Engine running
  • Throttle actuator commanded on
  • Time after engine start > 5.0 s
  • Throttle position sensor failure not detected
  • Fuel cut off not active
  • Fast throttle adaptation finished
  • Gradient intake manifold pressure -199.90 - 199.90 kPa/s
  • Barometric pressure plausibility diagnosis finished
  • Intake manifold modeled adaptation active
  • And
  • Choice of:
  • MAF sensor active
  • Or
  • Manifold pressure sensor active
  • And
  • Choice of:
  • pressure upstream throttle< 135.00 kPa
  • Or
  • Pressure upstream throttlenot active
  • And
  • Choice of:
  • BARO> 73.00; < 107.50[kPa]
  • Or
  • Barometric pressure sensornot active
  • 5.0 s
  • Continuous
  • General conditions:
  • Filtered lambda controller included correction and adaption > 30.0 %
  • And
  • Deviation throttle area controller < -45.0 %
P0107 Manifold Absolute Pressure/Barometric Pressure Sensor Circuit Low Manifold Pressure Sensor Short To Ground
  • Intake manifold pressure sensor voltage < 0.20 V
 
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Intake Manifold Sensor -GX9-. Refer to Intake Manifold Sensor -GX9-, CHECKING .
P0108 Manifold Absolute Pressure/Barometric Pressure Sensor Circuit High Manifold Pressure Sensor Short To Battery Voltage
  • Intake manifold pressure sensor voltage > 4.80 V
 
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Intake Manifold Sensor -GX9-. Refer to Intake Manifold Sensor -GX9-, CHECKING .
P0111 Intake Air Temperature Sensor 1 Circuit Range/Performance Bank 1 Intake Air Temperature Sensor @ Manifold Cross Check
  • High side: reference measuring
  • Diff. IAT @ manifold @ cold start vs. AAT @ cold start> 25.0K
  • Diff. IAT @ manifold @ cold start vs. ECT @ cylinder head @ cold start n.a. K
  • Diff. IAT @ manifold @ cold start vs. ECT @ radiator outlet @ cold start> 25.0 K
  • Min. amount of faulty reference measurements to detect defective sensor2.00[-]
  • Or
  • Low side: reference measuring
  • Diff. AAT @ cold start vs. IAT @ manifold @ cold start> 25.0 K
  • Diff. ECT @ cylinder head @ cold start vs. IAT @ manifold @ cold start> 25.0 K
  • Diff. ECT @ radiator outlet @ cold start vs. IAT @ manifold @ cold start> 25.0K
  • Min. amount of faulty reference measurements to detect defective sensor 2.00[-]
  • Engine off time>= 360.00 min
  • Engine off timeplausible
  • Time after engine start<= 1400.0 s
  • Depending on temperature slope
  • Diff. actual vs previous IAT< 256.0K
  • Diff. actual vs previous ECT@ cylinder headn.a. K
  • Diff. actual vs previous ECT@ radiator outlet< 256.0K
  • Diff. actual vs previous AAT< 256.0 K
  • For time>= 1.0 s
  • Depending on mean value condition
  • Mean value of all temperature sensors @ cold start>= -256° C
  • Number of valid sensors>= 2.00[-]
  • Depending on block heater / solar radiation detection
  • Time after engine start>= 0.5 s
  • Vehicle speed>= 22 mph
  • For time>= 20.0 s
  • Diff. actual IAT @ manifold vs. min. IAT @ manifold< 5.0 K
  • Diff. actual ECT @ cylinder head vs. min. ECT @ cylinder headn.a. K
  • Diff. actual AAT vs. min. AAT< 4.0 K
  • Diff. actual ECT @ radiator outlet vs. min. ECT @ radiator outlet< 1.1 K
  • 0.1 s
  • Once / DCY
  • 2 DCY
-- Check the Intake Manifold Sensor -GX9-. Refer to Intake Manifold Sensor -GX9-, CHECKING .
P0112 Intake Air Temperature Sensor 1 Circuit Low Bank 1 Intake Air Temperature Sensor Short To Ground
  • IAT sensor voltage < 0.10 V
 
  • 0.5 s
  • Continuous
P0113 Intake Air Temperature Sensor 1 Circuit High Bank 1 Intake Air Temperature Sensor open circuit
  • IAT sensor voltage > 4.50 V
 
P0116 Engine Coolant Temperature Sensor 1 Circuit Range/Performance Engine Coolant Temperature Sensor @ Cylinder Head Rationality Check Inappropriately Low
  • Diff. min temperature of cross check sensors vs. ECT @ cylinder head @ engine start >= 25° C
  • Cross checks finished
  • 1.0 s
  • Once / DCY
  • 2 DCY
-- Check the Engine Coolant Temperature Sensor -G62-. Refer to Engine Coolant Temperature Sensor -G62-, CHECKING .
Engine Coolant Temperature Sensor @ Cylinder Head Rationality Check High
  • Difference between maximum and minimum temperature of ECT @ cylinder head < 1° C
  • ECT @ cylinder head @ engine start> 40 - 80° C
  • ECT @ cylinder head> -256° C
  • IAT @ throttle-48...143° C
  • Depending on thermostat control:
  • ECT @ cylinder headn.a.° C
  • or
  • ECT @ cylinder headn.a.° C
  • Enginen.a.
  • And
  • Engine part load
  • Or
  • Engine full load
  • Engine speed> 1300 rpm
  • Vehicle speed>= 12 mph
  • Engine load> 2.00 %
  • For time>= 20.0 - 43.0 s
  • Engineidle
  • Vehicle speed< 3 mph
  • Or
  • Fuel cut offactive
  • Or
  • Engine stop for time>= 20.0 - 43.0 s
  • Time after engine start> 100 s
Engine Coolant Temperature Sensor @ Cylinder Head Rationality Check Low
  • Difference between modelled and measured cylinder head temperature > 5° C
  • ECT @ cylinder head -128 - 127° C
  • Time after engine start > 60.0 s
  • 30 s
  • Once / DCY
P0117 Engine Coolant Temperature Sensor 1 Circuit Low Engine Coolant Temperature Sensor @ Cylinder Head Short To Ground
  • ECT sensor voltage @ cylinder head < 0.30 V
 
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Engine Coolant Temperature Sensor -G62-. Refer to Engine Coolant Temperature Sensor -G62-, CHECKING .
P0118 Engine Coolant Temperature Sensor 1 Circuit High Engine Coolant Temperature Sensor @ Cylinder Head Short To Battery / Open Circuit
  • ECT sensor voltage @ cylinder head > 4.90 V
  • Modeled IAT @ throttle >= -33° C
  • Time after engine start> 60.0 s
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Engine Coolant Temperature Sensor -G62-. Refer to Engine Coolant Temperature Sensor -G62-, CHECKING .
P0121 Throttle/Pedal Position Sensor/Switch "A" Circuit Range/Performance Throttle Position Sensor 1 Rationality Check
  • Normalized difference between measured and modeled value of mass air flow from TPS 1 >= 1.00 [-]
  • Or
  • Relative mass air flow integral from TPS 1 > 60.0 [-]
  • Throttle adaptation not active
  • 0.01 s
  • Continuous
  • 2 DCY
-- Check the Throttle Valve Control Module -GX3-. Refer to Throttle Valve Control Module -GX3-, CHECKING .
  • Difference between TPS 1 and TPS 2 > 6.499° TPS
  • 0.3 s
  • Continuous
P0122 Throttle/Pedal Position Sensor/Switch "A" Circuit Low Throttle Position Sensor 1 Short To Ground / open circuit
  • Throttle position sensor 1 voltage < 0.15 V
 
  • 0.2 s
  • Continuous
  • 2 DCY
-- Check the Throttle Valve Control Module -GX3-. Refer to Throttle Valve Control Module -GX3-, CHECKING .
P0123 Throttle/Pedal Position Sensor/Switch "A" Circuit High Throttle Position Sensor 1 Short To Battery Voltage
  • Throttle position sensor 1 voltage > 4.85 V
 
  • 0.2 s
  • Continuous
  • 2 DCY
-- Check the Throttle Valve Control Module -GX3-. Refer to Throttle Valve Control Module -GX3-, CHECKING .
P0131 O2 Sensor Circuit Low Voltage Bank 1 Sensor 1 Oxygen Sensors Front Short To Ground
  • O2S sensor voltage < 0.15 V
  • Engine running
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter -GX10-, CHECKING .
P0132 O2 Sensor Circuit High Voltage Bank 1 Sensor 1 Oxygen Sensors Front Short To Battery Voltage
  • O2S sensor voltage > 5.20 - 5.35 V
  • Engine running
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter -GX10-, CHECKING .
P0133  O2 Sensor Circuit Slow Response Bank 1 Sensor 1 Oxygen Sensors Front Response Check
  • Dynamic Path:
  • Lambda value vs. modeled lambda value >= 1.10 [-]
  • Or
  • Ratio of failed diagnostic cycle > n.a. [-]
  • General conditions:
  • Injection mode change (DFI/MFI)not active
  • ECT @ cylinder head>= -48° C
  • Vehicle speed> 0 mph
  • Integrated air mass after gear change> 0.0 g
  • Air mass, lower range>= 0.00 mg/rev
  • Air mass, upper range<= 1389.00 mg/rev
  • Counter of integrated mass for fuel in oil< 255.00[-]
  • And
  • Time after engine start>= 0.0 s
  • Or
  • Integrated air mass per cylinder>= 0.00 kg
  • Depending on canister and catalyst purge:
  • Evap purge n.a.
  • Or
  • Evap purgen.a.
  • Or
  • Evap purgen.a.
  • Canister load calculationn.a.
  • Or
  • Evap purgen.a.
  • Canister loadn.a.[-]
  • And
  • Case 1:
  • O2S frontn.a.
  • Lambda stimulationn.a.
  • Upper limit of lambda controller outputn.a.
  • Lower limit of lambda controller outputn.a.
  • Engine speedn.a.rpm
  • Air massn.a. mg/rev
  • MAFn.a. kg/h
  • Catalyst purgen.a.
  • And
  • Depending on limited dynamic conditions:
  • Integrated air massn.a.g
  • Dynamic engine speedn.a.g
  • Dynamic air massn.a.mg/rev
  • Dynamic lambdan.a.%
  • Or
  • Dynamic engine speedn.a.rpm
  • Diff. actual engine load vs. filtered engine load in limited dynamic conditions, lower rangen.a.kg/h
  • Diff. actual engine load vs. filterd engine load in limited dynamic conditions, upper rangen.a.kg/h
  • Dynamic torquen.a.[-]
  • Case 2: lambda set value adjustment for conditioning and measuringactive
  • 2.4 s
  • Once / DCY
  • 1 DCY
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter -GX10-, CHECKING .
  • Delay path:
  • Lambda delay value vs. modeled lambda value > 1.10 [-]
  • General conditions:
  • MAF >= 0.0 mg/rev
  • MAF <= 1, 389.0 mg/rev
  • Vehicle speed >= 0 mph
  • Time after engine start >= 0.0 s
  • Integrated mass for fuel in oil < 255.0 [-]
  • Engine speed 1, 216 - 3, 008 RPM
  • MAF (intake air rate) 20.0 - 150.0 kg/h
  • Vehicle speed >= 3 mph
  • Integrated MAF per cylinder >= 0.30 - 2.0 kg
  • Depending on dynamic conditions:
  • Dynamic engine speed < 288 RPM
  • Dynamic torque < 80.0 Nm
  • Dynamic MAF < 70.0 kg/h
  • For time >= 0.6 s
  • And depending on canister and catalyst purge:
  • Evap purge n.a.
  • Or
  • Canister load calculation n.a
  • Or
  • Canister load <= n.a. [-]
  • 13.2 s
  • Once / DCY
P0135  O2 Sensor Heater Circuit Bank 1 Sensor 1 Oxygen Sensors Heater Front Functional Check
  • O2S ceramic temperature, < 630° C
  • O2S heater commanded on
  • For time >= 10.0 s
  • 20 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter -GX10-, CHECKING .
P0137 O2 Sensor Circuit Low Voltage Bank 1 Sensor 2 Oxygen Sensors Rear Short To Ground
  • O2S sensor voltage < 0.15 V
  • O2S heater active
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter -GX7-, CHECKING .
P0138 O2 Sensor Circuit High Voltage Bank 1 Sensor 2 Oxygen Sensors Rear Short To Battery
  • O2S sensor voltage > 5.2 - 5.35 V
  • O2S heater active
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter -GX7-, CHECKING .
P013A  O2 Sensor Slow Response - Rich to Lean Bank 1 Sensor 2 Oxygen Sensors Rear Response Check
  • Gradient sensor voltage< 900.00mV/s
  • General conditions:
  • Intrusive lambda ramp requestnot active
  • Internal resistance O2S rear<= 700.00 Ohm
  • Counter of integrated mass for fuel in oil< 255.00[-]
  • Catalyst monitor lambda modulation requestactive
  • Vehicle speed19 - 158 mph
  • Barometric pressure>= 0.00kPa
  • Catalyst overheating protectionnot active
  • Turbine overheating protectionnot active
  • O2S rearready
  • O2S frontready
  • ECT @ cylinder head> 60° C
  • IAT @ manifold> -48° C
  • Modeled catalyst temperature @ start of diagnosis> 510° C
  • Modeled catalyst temperature @ during diagnosis470 - 830° C
  • Diff.between dynamic and stationary catalyst temperature-150 - 150° C
  • Integrated air mass, catalyst temp. conditions fulfilled>= 0.0 g
  • Modeled EGT @ O2S rear<= 900° C
  • MAF per cylinder22.50 - 150.00 kg/h
  • Air mass, lower range>= 0.00 mg/rev
  • Air mass, upper range<= 650.00 - 1389.00mg/rev
  • And
  • Engine loadn.a.%
  • Air mass setpointn.a.g/rev
  • Accelerator pedal valuen.a. %
  • For timen.a. s
  • And
  • Low dynamic conditions
  • Dynamic engine speed< 50 rpm
  • Dynamic air mass< 50.00 mg/rev
  • Dynamic lambda controller output< 20.00 %
  • And
  • Integrated air mass after dynamic conditions are fulfilled> 20.0 g
  • Time after a catalyst purge phase>= 1.0s
  • O2S rear voltage @ diagnosis start>= 0.55V
  • Integrated air mass>= 0.0 g
  • Integrated heat energy>= 550 - 700 kJ
  • Engine speed1, 088 - 3, 008 rpm
  • Deviation of lambda controller output< 50.00 %
  • Proportional part of secondary fuel control loopnot calibrated
  • Coasting functionnot active
  • O2S heater rearactive
  • Lambda adaptationnot active
  • Valve lift not active
  • And
  • Depending on Lambda control:
  • Sum of integral and proportional part of secondary fuel control loop before diagnosis< 0.10 [-]
  • Or
  • Sum of integral and proportional part of secondary fuel control loop during diagnosis< 0.25 [-]
  • Depending on canister purge:
  • Canister loadn.a.[-]
  • Evap purge flown.a.
  • Or
  • Canister load calculationn.a.
  • Evap purge flow n.a.
  • Or
  • Evap purge valven.a.
  • Or
  • Evap purge valven.a.
  • Or
  • Evap purge n.a.
  • Or
  • Depending on canister purge closing:
  • Canister purge (conditions)n.a.
  • Canister purge valve (closing time)n.a.s
  • And
  • Choice of:
  • Evap purge valven.a.
  • Or
  • Evap purge valven.a.
  • And
  • Modeled air mass integral> 50.0 g
  • Integrated air mass per cylinder>= 1.40 - 1.80kg
  • 0 FTP75: 50 s
  • Once / DCY
  • 1 DCY
-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter -GX7-, CHECKING .
P013B  O2 Sensor Slow Response - Lean to Rich Bank 1 Sensor 2 Oxygen Sensors Rear Response Check
  • Gradient sensor voltage< 900.00mV/s
  • General conditions:
  • Intrusive lambda ramp requestnot active
  • Internal resistance O2S rear<= 700.00 Ohm
  • Counter of integrated mass for fuel in oil< 255.00[-]
  • Catalyst monitor lambda modulation requestactive
  • Vehicle speed>= 19 mph
  • Barometric pressure>= 0.00 kPa
  • Catalyst overheating protectionnot active
  • Turbine overheating protectionnot active
  • O2S rearready
  • O2S frontready
  • ECT @ cylinder head> 60° C
  • IAT @ manifold> -48° C
  • Modeled catalyst temperature @ start of diagnosis 510 - 1, 775° C
  • Modeled catalyst temperature @ during diagnosis470 - 830° C
  • Diff. between dynamic and stationary catalyst temperature-150 - 150° C
  • Integrated air mass, catalyst temp. conditions fulfilled>= 0.0 g
  • Modeled EGT @ O2S rear0 - 900° C
  • MAF per cylinder22.50 - 150.00kg/h
  • Air mass, lower range>= 0.00 mg/rev
  • Air mass, upper range<= 650.00 - 1, 389.00mg/rev
  • And
  • Engine loadn.a.%
  • Air mass setpointn.a.[g/rev]
  • Accelerator pedal valuen.a.%
  • For timen.a.s
  • And
  • Low dynamic conditions
  • Dynamic engine speed< 50 rpm
  • Dynamic air mass< 50, 000 mg/rev
  • Dynamic lambda controller output< 20.00 %
  • And
  • Integrated air mass after dynamic conditions are fulfilled> 20.0 g
  • Time after a catalyst purge phase>= 1.0s
  • O2S rear voltage @ diagnosis start>= 0.55V
  • Integrated air mass>= 0.0 g
  • Integrated heat energy>= 550 - 700 kJ
  • Engine speed1, 088 - 3, 008 rpm
  • Deviation of lambda controller output< 50.00 %
  • Proportional part of secondary fuel control loopnot calibrated %
  • Coasting functionnot active
  • O2S heater rearactive
  • Lambda adaptationnot active
  • Valve lift not active
  • And
  • Depending on Lambda control:
  • Sum of integral and proportional part of secondary fuel control loop before diagnosis< 0.10 [-]
  • Or
  • Sum of integral and proportional part of secondary fuel control loop during diagnosis< 0.25 [-]
  • Depending on canister purge:
  • Canister loadn.a.[-]
  • Evap purge flown.a.
  • Or
  • Canister load calculationn.a.
  • Evap purge flow n.a.
  • Or
  • Evap purge valven.a.
  • Or
  • Evap purge valven.a.
  • Or
  • Evap purge n.a.
  • Or
  • Depending on canister purge closing:
  • Canister purge (conditions)n.a.
  • Canister purge valve (closing time)n.a.s
  • And
  • Choice of:
  • Evap purge valven.a.
  • Or
  • Evap purge valven.a.
  • And
  • Modeled air mass integral> 50.0 g
  • Integrated air mass per cylinder>= 1.45 - 1.80kg
  • 0 FTP75: 50 s
  • Once / DCY
  • 1 DCY
-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter -GX7-, CHECKING .
P013E  O2 Sensor Delayed Response - Rich to Lean Bank 1 Sensor 2 Oxygen Sensors Rear Delayed Response Monitoring, Delay Measurement
  • Sensor signal delay time > 0.9 s
  • General conditions:
  • Intrusive lambda ramp requestnot active
  • Catalyst monitor lambda modulation requestactive
  • Vehicle speed>= 19 mph
  • Barometric pressure>= 0.00kPa
  • Catalyst overheating protectionnot active
  • Turbine overheating protectionnot active
  • O2S rearready
  • O2S frontready
  • ECT @ cylinder head> 60° C
  • IAT @ manifold> -48° C
  • Modeled catalyst temperature @ start of diagnosis> 510° C
  • Modeled catalyst temperature @ during diagnosis470 - 830° C
  • Diff. between dynamic and stationary catalyst temperature-150 - 150° C
  • Integrated air mass, catalyst temp. conditions fulfilled>= 0.0 g
  • Modeled EGT @ O2S rear<= 900° C
  • MAF per cylinder22.50 - 150.00 kg/h
  • Air mass, lower range>= 0.00 mg/rev
  • Air mass, upper range<= 650.00 - 1, 389.00mg/rev
  • And
  • Engine loadn.a. %
  • Air mass setpointn.a. g/rev
  • Accelerator pedal valuen.a. %
  • For timen.a.[s]
  • And
  • Low dynamic conditions
  • Dynamic engine speed< 50 rpm
  • Dynamic air mass< 50.00 mg/rev
  • Dynamic lambda controller output< 20.00%
  • And
  • Integrated air mass after dynamic conditions are fulfilled> 20.0 g
  • Time after a catalyst purge phase>= 1.0 s
  • O2S rear voltage @ diagnosis start>= 0.55V
  • Integrated air mass>= 0. [g
  • Integrated heat energy>= 550.00 - 700.00 kJ
  • Engine speed1, 088 - 3, 008 rpm
  • Deviation of lambda controller output< 50.00%
  • Proportional part of secondary fuel control loopnot calibrated[%]
  • Coasting functionnot active
  • O2S heater rearactive
  • Lambda adaptationnot active
  • Valve lift not active
  • And
  • Depending on Lambda control:
  • Sum of integral and proportional part of secondary fuel control loop before diagnosis< 0.10 [-]
  • Or
  • Sum of integral and proportional part of secondary fuel control loop during diagnosis< 0.25 [-]
  • Depending on canister purge:
  • Canister loadn.a.[-]
  • Evap purge flown.a.
  • Or
  • Canister load calculationn.a.
  • Evap purge flown.a.
  • Or
  • Evap purge valven.a.
  • Or
  • Evap purge valven.a.
  • Or
  • Evap purgen.a.
  • Or
  • Depending on canister purge closing:
  • Canister purge (conditions)n.a.
  • Canister purge valve (closing time)n.a.[s]
  • And
  • Choice of:
  • Evap purge valven.a.
  • Or
  • Evap purge valven.a.
  • And
  • Modeled air mass integral> 50.0 g
  • Integrated air mass per cylinder>= 1.40 - 1.80kg
  • 0 FTP75: 50 s
  • Once / DCY
  • 1 DCY
-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter -GX7-, CHECKING .
P013F  O2 Sensor Delayed Response - Lean to Rich Bank 1 Sensor 2 Oxygen Sensors Rear Delayed Response Monitoring, Delay Measurement
  • Sensor signal delay time > 1.5 s
  • General conditions:
  • Intrusive lambda ramp requestnot active
  • Catalyst monitor lambda modulation requestactive
  • Vehicle speed>= 19 mph
  • Barometric pressure>= 0.00 kPa
  • Catalyst overheating protectionnot active
  • Turbine overheating protectionnot active
  • O2S rearready
  • O2S frontready
  • ECT @ cylinder head> 60° C
  • IAT @ manifold> -48° C
  • Modeled catalyst temperature @ start of diagnosis> 510° C
  • Modeled catalyst temperature @ during diagnosis470 - 830° C
  • Diff. between dynamic and stationary catalyst temperature-150 - 150° C
  • Integrated air mass, catalyst temp. conditions fulfilled>= 0.0 g
  • Modeled EGT @ O2S rear<= 900° C
  • MAF per cylinder22.50 - 150.00 kg/h
  • Air mass, lower range>= 0.00 mg/rev
  • Air mass, upper range<= 650.00 - 1, 389.00 mg/rev
  • And
  • Engine loadn.a.%
  • Air mass setpointn.a. g/rev
  • Accelerator pedal valuen.a. %
  • For timen.a. s
  • And
  • Low dynamic conditions
  • Dynamic engine speed< 50 rpm
  • Dynamic air mass< 50.00 mg/rev
  • Dynamic lambda controller output< 20.00 %
  • And
  • Integrated air mass after dynamic conditions are fulfilled> 20.0 g
  • Time after a catalyst purge phase>= 1.0s
  • O2S rear voltage @ diagnosis start>= 0.55V
  • Integrated air mass>= 0.0 g
  • Integrated heat energy>= 550.00 - 700.00 kJ
  • Engine speed1, 088 - 3, 008 rpm
  • Deviation of lambda controller output< 50.00 %
  • Proportional part of secondary fuel control loopnot calibrated
  • Coasting functionnot active
  • O2S heater rearactive
  • Lambda adaptationnot active
  • Valve lift not active
  • And
  • Depending on Lambda control:
  • Sum of integral and proportional part of secondary fuel control loop before diagnosis< 0.10 [-]
  • Or
  • Sum of integral and proportional part of secondary fuel control loop during diagnosis< 0.25 [-]
  • Depending on canister purge:
  • Canister loadn.a.[-]
  • Evap purge flown.a.
  • Or
  • Canister load calculationn.a.
  • Evap purge flown.a.
  • Or
  • Evap purge valven.a.
  • Or
  • Evap purge valven.a.
  • Or
  • Evap purgen.a.
  • Or
  • Depending on canister purge closing:
  • Canister purge (conditions)n.a.
  • Canister purge valve (closing time)n.a. s
  • And
  • Choice of:
  • Evap purge valven.a.
  • Or
  • Evap purge valven.a.
  • And
  • Modeled air mass integral> 50.0 g
  • Integrated air mass per cylinder>= 1.40 - 1.80kg
  • 0 (FTP75: 50) s
  • Once / DCY
  • 1 DCY
-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter -GX7-, CHECKING .
P0140 O2 Sensor Circuit No Activity Detected Bank 1 Sensor 2 Oxygen Sensors Rear Open Circuit
  • Internal resistance of O2S (binary) > 25, 000.0 Ohm
 
  • 2.5 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter -GX7-, CHECKING .
P0141  O2 Sensor Heater Circuit Bank 1 Sensor 2 Oxygen Sensors Heater Rear Out Of Range High
  • Internal resistance of O2S (binary) 700.0 - 25, 000.0 Ohm
  • O2S heatercommanded on
  • For time >= 10.0 s
  • 20 s
  • Once / DCY
  • 2 DCY
-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter -GX7-, CHECKING .
P0149 Fuel Timing Error Injection Valves Supply Voltage Out Of Range Low
  • Boost voltage < 30.0 V
  • Engine running >= 0.3 s
  • 3.6 s
  • Continuous
  • 2 DCY
-- Check the Engine Control Module -J623-. Refer to appropriate repair information.
  • Boost voltage <= 50.0 V
Injection Valves Supply Voltage Out Of Range High
  • Boost voltage > 75.0 V
P0171 System Too Lean Bank 1 Fuel System, System Too Lean
  • Lambda controller output > 35.0 %
  • Lambda control closed loop
  • Mass air flow > 60.0 mg/rev
  • Engine speed > 576 RPM
  • ECT @ cylinder head > 20° C
  • IAT at intake manifold > -48° C
  • AAT > -48° C
  • And
  • Evap purge valveclosed
  • Or
  • Canister load<= 1.20[-]
  • Evap purge flowat max. value
  • Or
  • Depending on canister purge min:
  • Lower limit of lambda controller outputn.a.
  • Or
  • Upper limit of lambda controller outputn.a.
  • And
  • Evap purge flowat min. value
  • 60 s
  • Continuous
  • 2 DCY
-- Check the intake and vacuum hoses for leaks, Check the Positive Crankcase Ventilation, also make sure the oil dipstick is properly secured.-- Listen to and visually inspect the Exhaust system to insure there are no leaks.-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter -GX10-, CHECKING .-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter -GX7-, CHECKING .
P0172 System Too Rich Bank 1 Fuel System, System Too Rich
  • Lambda controller output < -35.0 %
  • Lambda control closed loop
  • Mass air flow > 60.0 mg/rev
  • Engine speed > 576 RPM
  • ECT @ cylinder head > 20° C
  • IAT at intake manifold > -48° C
  • AAT > -48° C
  • Oil dilution not detected
  • And
  • Evap purge valveclosed
  • Or
  • Canister load<= 1.20[-]
  • Evap purge flowat max. value
  • Or
  • Depending on canister purge min:
  • Lower limit of lambda controller outputn.a.
  • Or
  • Upper limit of lambda controller outputn.a.
  • And
  • Evap purge flowat min. value
  • 60 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter -GX10-, CHECKING .-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter -GX7-, CHECKING .-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING . -- Check the Evaporative Emission System for contamination. Refer to appropriate repair information.
P0190 Fuel Pressure Regulator 1 Control Circuit/Open Fuel System Pressure Sensor High Pressure Side Short To Battery / Open Circuit
  • High fuel pressure sensor voltage > 4.80 V
 
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the Fuel Pressure Sensor -G247-. Refer to Fuel Pressure Sensor -G247-, CHECKING .-- Check the fuel pressure. Refer to appropriate repair information.
P0191 Fuel Rail Pressure Sensor Circuit Range/Performance Bank 1 Fuel Rail High Pressure Side Out Of Range High
  • Fuel pressure > 26, 500.18 kPa
  • Engine running
  • Engine speed < 6, 816 RPM
  • Time after engine start > 10.0 s
  • 5.0 s
  • Continuous
  • 2 DCY
-- Check the Fuel Pressure Sensor -G247-. Refer to Fuel Pressure Sensor -G247-, CHECKING .-- Check the fuel pressure. Refer to appropriate repair information.
P0192 Fuel Rail Pressure Sensor Circuit Low Bank 1 Fuel System Pressure Sensor High Pressure Side Short To Ground
  • High fuel pressure sensor voltage < 0.20 V
 
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the Fuel Pressure Sensor -G247-. Refer to Fuel Pressure Sensor -G247-, CHECKING .-- Check the fuel pressure. Refer to appropriate repair information.
P0201 Cylinder 1 Injector "A" Circuit Injection Valves Electrical Error
  • Indeterminate fault pattern via power stage diagnosis detected
  • And
  • Injector low side voltage < 2.0 V
  • Injector low side switch current driver stage internal value
  • Or
  • Injector low side voltage < 2.0 V
  • Injector high side switch current driver stage internal value
  • Or
  • Injector low side voltage < 2.0 V
  • Injector low side switch current (hardware values) driver stage internal value
  • Or
  • Injector voltage < 2.0 V
  • Injector low side switch current driver stage internal value
  • Or
  • Injector voltage < 2.0 V
  • Injector low side switch current (hardware values) driver stage internal value
  • Or
  • Injector load resistance to ground and battery > 20.0 Ohm
  • Injector low side switch current driver stage internal value
  • Or
  • Injector load resistance to ground and battery > 20.0 Ohm
  • Injector high side switch current driver stage internal value
  • Or
  • Power stage temperature > 150° C
  • Engine running
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
  • 8, 640.0° CRK
  • Continuous
  • 2 DCY
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
Injection Valves Electrical Error Open Circuit
  • Fault pattern for open circuit via power stage diagnosis detected
  • Injector low side voltage < 2.0 V
  • Engine stop not active
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
Injection Valves Electrical Error Short Circuit
  • Fault pattern for short circuit via power stage diagnosis detected
  • Injector current rise time during peak phase < 0.064 ms
P0202 Cylinder 2 Injector "A" Circuit Injection Valves Electrical Error
  • Indeterminate fault pattern via power stage diagnosis detected
  • And
  • Injector low side voltage < 2.0 V
  • Injector low side switch current driver stage internal value
  • Or
  • Injector low side voltage < 2.0 V
  • Injector high side switch current driver stage internal value
  • Or
  • Injector low side voltage < 2.0 V
  • Injector low side switch current (hardware values) driver stage internal value
  • Or
  • Injector voltage < 2.0 V
  • Injector low side switch current driver stage internal value
  • Or
  • Injector voltage < 2.0 V
  • Injector low side switch current (hardware values) driver stage internal value
  • Or
  • Injector load resistance to ground and battery > 20.0 Ohm
  • Injector low side switch current driver stage internal value
  • Or
  • Injector load resistance to ground and battery > 20.0 Ohm
  • Injector high side switch current driver stage internal value
  • Or
  • Power stage temperature > 150° C
  • Engine running
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
  • 8, 640.0° CRK
  • Continuous
  • 2 DCY
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
Injection Valves Electrical Error Open Circuit
  • Fault pattern for open circuit via power stage diagnosis detected
  • Injector low side voltage < 2.0 V
  • Engine stop not active
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
Injection Valves Electrical Error Short Circuit
  • Fault pattern for short circuit via power stage diagnosis detected
  • Injector current rise time during peak phase < 0.064 ms
P0203 Cylinder 3 Injector "A" Circuit Injection Valves Electrical Error
  • Indeterminate fault pattern via power stage diagnosis detected
  • And
  • Injector low side voltage < 2.0 V
  • Injector low side switch current driver stage internal value
  • Or
  • Injector low side voltage < 2.0 V
  • Injector high side switch current driver stage internal value
  • Or
  • Injector low side voltage < 2.0 V
  • Injector low side switch current (hardware values) driver stage internal value
  • Or
  • Injector voltage < 2.0 V
  • Injector low side switch current driver stage internal value
  • Or
  • Injector voltage < 2.0 V
  • Injector low side switch current (hardware values) driver stage internal value
  • Or
  • Injector load resistance to ground and battery > 20.0 Ohm
  • Injector low side switch current driver stage internal value
  • Or
  • Injector load resistance to ground and battery > 20.0 Ohm
  • Injector high side switch current driver stage internal value
  • Or
  • Power stage temperature > 150° C
  • Engine running
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
  • 8, 640.0° CRK
  • Continuous
  • 2 DCY
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
Injection Valves Electrical Error Open Circuit
  • Fault pattern for open circuit via power stage diagnosis detected
  • Injector low side voltage < 2.0 V
  • Engine stop not active
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
Injection Valves Electrical Error Short Circuit
  • Fault pattern for short circuit via power stage diagnosis detected
  • Injector current rise time during peak phase < 0.064 ms
P0204 Cylinder 4 Injector "A" Circuit Injection Valves Electrical Error
  • Indeterminate fault pattern via power stage diagnosis detected
  • And
  • Injector low side voltage < 2.0 V
  • Injector low side switch current driver stage internal value
  • Or
  • Injector low side voltage < 2.0 V
  • Injector high side switch current driver stage internal value
  • Or
  • Injector low side voltage < 2.0 V
  • Injector low side switch current (hardware values) driver stage internal value
  • Or
  • Injector voltage < 2.0 V
  • Injector low side switch current driver stage internal value
  • Or
  • Injector voltage < 2.0 V
  • Injector low side switch current (hardware values) driver stage internal value
  • Or
  • Injector load resistance to ground and battery > 20.0 Ohm
  • Injector low side switch current driver stage internal value
  • Or
  • Injector load resistance to ground and battery > 20.0 Ohm
  • Injector high side switch current driver stage internal value
  • Or
  • Power stage temperature > 150° C
  • Engine running
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
  • 8, 640.0° CRK
  • Continuous
  • 2 DCY
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
Injection Valves Electrical Error Open Circuit
  • Fault pattern for open circuit via power stage diagnosis detected
  • Injector low side voltage < 2.0 V
  • Engine stop not active
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
Injection Valves Electrical Error Short Circuit
  • Fault pattern for short circuit via power stage diagnosis detected
  • Injector current rise time during peak phase < 0.064 ms
P0221 Throttle/Pedal Position Sensor/Switch "B" Circuit Range/Performance Throttle Position Sensor 2 Rationality Check
  • Normalized difference between measured and modeled value of mass air flow from TPS 2 >= 1.0 [-]
  • Or
  • Relative mass air flow integral from TPS 2> 60.00 -
  • Throttle adaptation (@ initial start or after detection of throttle exchange or checksum error) not active
  • 0.01 s
  • Continuous
  • 2 DCY
-- Check the Throttle Valve Control Module -GX3-. Refer to Throttle Valve Control Module -GX3-, CHECKING .
P0222 Throttle/Pedal Position Sensor/Switch "B" Circuit Low Throttle Position Sensor 2 Short To Ground / Open Circuit
  • Throttle position sensor 2 voltage < 0.15 V
 
  • 0.2 s
  • Continuous
  • 2 DCY
-- Check the Throttle Valve Control Module -GX3-. Refer to Throttle Valve Control Module -GX3-, CHECKING .
P0223 Throttle/Pedal Position Sensor/Switch "B" Circuit High Throttle Position Sensor 2 Short To Battery Voltage
  • Throttle position sensor 2 voltage > 4.85 V
 
  • 0.2 s
  • Continuous
  • 2 DCY
-- Check the Throttle Valve Control Module -GX3-. Refer to Throttle Valve Control Module -GX3-, CHECKING .
P0230 Fuel Pump Circuit COM: Fuel Pump Control Module (FPCM) communication with FPCM
  • FP sensor: short to ground failure feedback>= 2.00[-]
  • Engineon
  • 2.0 s
  • Continuous
  • 2 DCY
 
  • FP sensor: open circuit failure feedback>= 2.00[-]
  • 2.2 s
  • Continuous
P0236 Turbocharger/Supercharger Boost Sensor "A" Circuit Range/Performance Turbocharger Boost Pressure Sensor Rationality Check
  • Diff. barometric pressure vs. upstream throttle pressure >= 8.50 kPa
  • Diff. upstream throttle pressure vs. intake manifold pressure >= 8.50 kPa
  • Or
  • Diff. barometric pressure vs. intake manifold pressure < 8.50 kPa
  • Case 1:
  • Engine stop at start of DCY
  • Enginestopped
  • Vehicle speed< 1 mph
  • Delay after engine stop>= 5.0 s
  • Case 2:
  • Engine stop during DCY
  • Engine stopped
  • Vehicle speed < 1 mph
  • Delay after engine stop >= 5.0 s
  • For time >= 10.0 s
  • 3.0 s
  • Once / DCY
  • 2 DCY
-- Check the Charge Air Pressure Sensor -G31-. Refer to Charge Air Pressure Sensor -G31-, CHECKING .
P0237 Turbocharger/Supercharger Boost Sensor "A" Circuit Low Turbocharger Boost pressure Sensor Short To Ground
  • Turbocharger boost pressure sensor voltage < 0.20 V
 
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Charge Air Pressure Sensor -G31-. Refer to Charge Air Pressure Sensor -G31-, CHECKING .
P0238 Turbocharger/Supercharger Boost Sensor "A" Circuit High Turbocharger Boost pressure Sensor Short To Battery Voltage
  • Turbocharger boost pressure sensor voltage > 4.80 V
 
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Charge Air Pressure Sensor -G31-. Refer to Charge Air Pressure Sensor -G31-, CHECKING .
P025A Fuel Pump Module "A" Control Circuit/Open Fuel Pump Open Circuit
  • Signal voltage, lower range > 1.92 - 2.21 V
  • And
  • Signal voltage, upper range (hardware values) < 2.84 - 3.25 V
  • Commanded PWM 9.80 - 92.20 %
  • Fuel pump commanded off
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Fuel Pump Control Module -J538- / Fuel Delivery Unit -GX1-. Refer to Fuel Pump Control Module -J538- /Fuel Delivery Unit -GX1-, CHECKING .
P025C Fuel Pump Module "A" Control Circuit Low Fuel Pump Short To Ground
  • Signal voltage (hardware values) < 1.92 - 2.21 V
  • Commanded PWM 9.80 - 92.20 %
  • Fuel pump commanded off
  • 3.0 s
  • Continuous
  • 2 DCY
-- Check the Fuel Pump Control Module -J538- / Fuel Delivery Unit -GX1-. Refer to Fuel Pump Control Module -J538- /Fuel Delivery Unit -GX1-, CHECKING .
P025D Fuel Pump Module "A" Control Circuit High Fuel Pump Short To Battery Voltage
  • Power stage temperature > 160 - 200° C
  • Or
  • Signal current (hardware values) driver stage internal value
  • Commanded PWM 9.80 - 92.20 %
  • Fuel pump commanded on
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Fuel Pump Control Module -J538- / Fuel Delivery Unit -GX1-. Refer to Fuel Pump Control Module -J538- /Fuel Delivery Unit -GX1-, CHECKING .
P0261 Cylinder 1 Injector "A" Circuit Low Injection Valves Short To Ground
  • Fault pattern for short to ground via powerstage diagnosis detected
  • Injector voltage < 2.0 V
  • Engine stop not active
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
  • 8, 640.0° CRK
  • Continuous
  • 2 DCY
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
Injection Valves Short To Ground (High Side)
  • Injector driver voltage < 2 V
  • And
  • Injector driver high side switch current (hardware values) driver stage internal value
  • Engine running
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 ms
  • 720° CRK
  • Continuous
Injection Valves Short To Ground (Low Side)
  • Injector driver voltage < 2 V
  • And
  • Injector driver high side switch current driver stage internal value
  • And
  • Injector driver low side switch current (hardware values) driver stage internal value
P0262 Cylinder 1 Injector "A" Circuit High Injection Valves Short To Battery Plus
  • Fault pattern for short to Battery plus via powerstage diagnosis detected
  • Injector voltage > 2.0 V
  • Engine stop not active
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
  • 8, 640.0° CRK
  • Continuous
  • 2 DCY
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
Injection Valves Short To Battery Plus (High Side)
  • injector driver voltage > 2.0 V
  • And
  • Injector driver high side switch current (hardware values) driver stage internal value
  • Engine running
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
  • 720° CRK
  • Continuous
Injection Valves Short To Battery Plus (Low Side)
  • Injector driver voltage > 2.0 V
  • And
  • Injector driver low side switch current (hardware values) driver stage internal value
P0264 Cylinder 2 Injector "A" Circuit Low Injection Valves Short To Ground
  • Fault pattern for short to ground via powerstage diagnosis detected
  • Injector voltage < 2.0 V
  • Engine stop not active
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
  • 8, 640.0° CRK
  • Continuous
  • 2 DCY
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
Injection Valves Short To Ground (High Side)
  • Injector driver voltage < 2 V
  • And
  • Injector driver high side switch current (hardware values) driver stage internal value
  • Engine running
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
  • 720° CRK
  • Continuous
Injection Valves Short To Ground (Low Side)
  • Injector driver voltage < 2 V
  • And
  • Injector driver high side switch current driver stage internal value
  • And
  • Injector driver low side switch current (hardware values) driver stage internal value
P0265 Cylinder 2 Injector "A" Circuit High Injection Valves Short To Battery Plus
  • Fault pattern for short to Battery plus via powerstage diagnosis detected
  • Injector voltage > 2.0 V
  • Engine stop not active
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
  • 8, 640.0° CRK
  • Continuous
  • 2 DCY
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
Injection Valves Short To Battery Plus (High Side)
  • Injector driver voltage > 2.0 V
  • And
  • Injector driver high side switch current (hardware values) driver stage internal value
  • Engine running
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
  • 720° CRK
  • Continuous
Injection Valves Short To Battery Plus (Low Side)
  • Injector driver voltage > 2.0 V
  • And
  • Injector driver low side switch current (hardware values) driver stage internal value
P0267 Cylinder 3 Injector "A" Circuit Low Injection Valves Short To Ground
  • Fault pattern for short to ground via powerstage diagnosis detected
  • Injector voltage < 2.0 V
  • Engine stop not active
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
  • 8, 640.0° CRK
  • Continuous
  • 2 DCY
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
Injection Valves Short To Ground (High Side)
  • Injector driver voltage < 2 V
  • And
  • Injector driver high side switch current (hardware values) driver stage internal value
  • Engine running
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
  • 720° CRK
  • Continuous
Injection Valves Short To Ground (Low Side)
  • Injector driver voltage < 2 V
  • And
  • Injector driver high side switch current driver stage internal value
  • And
  • Injector driver low side switch current (hardware values) driver stage internal value
P0268 Cylinder 3 Injector "A" Circuit High Injection Valves Short To Battery Plus
  • Fault pattern for short to Battery plus via powerstage diagnosis detected
  • Injector voltage > 2.0 V
  • Engine stop not active
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
  • 8, 640.0° CRK
  • Continuous
  • 2 DCY
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
Injection Valves Short To Battery Plus (High Side)
  • Injector driver voltage > 2.0 V
  • And
  • Injector driver high side switch current (hardware values) driver stage internal value
  • Engine running
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
  • 720° CRK
  • Continuous
Injection Valves Short To Battery Plus (Low Side)
  • Injector driver voltage > 2.0 V
  • And
  • Injector driver low side switch current (hardware values) driver stage internal value
P0270 Cylinder 4 Injector "A" Circuit Low Injection Valves Short To Ground
  • Fault pattern for short to ground via powerstage diagnosis detected
  • Injector voltage < 2.0 V
  • Engine stop not active
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
  • 8, 640.0° CRK
  • Continuous
  • 2 DCY
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
Injection Valves Short To Ground (High Side)
  • Injector driver voltage < 2 V
  • And
  • Injector driver high side switch current (hardware values) driver stage internal value
  • Engine running
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
  • 720° CRK
  • Continuous
Injection Valves Short To Ground (Low Side)
  • Injector driver voltage < 2 V
  • And
  • Injector driver high side switch current driver stage internal value
  • And
  • Injector driver low side switch current (hardware values) driver stage internal value
P0271 Cylinder 4 Injector "A" Circuit High Injection Valves Short To Battery Plus
  • Fault pattern for short to Battery plus via powerstage diagnosis detected
  • Injector voltage > 2.0 V
  • Engine stop not active
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
  • 8, 640.0° CRK
  • Continuous
  • 2 DCY
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
Injection Valves Short To Battery Plus (High Side)
  • Injector driver voltage > 2.0 V
  • And
  • Injector driver high side switch current (hardware values) driver stage internal value
  • Engine running
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
  • 720° CRK
  • Continuous
Injection Valves Short To Battery Plus (Low Side)
  • Injector driver voltage > 2.0 V
  • And
  • Injector driver low side switch current (hardware values) driver stage internal value
P0300 Random/Multiple Cylinder Misfire Detected Misfire Crankshaft Speed Fluctuation (Multiple)
  • Number of cylinders with emission threshold misfire within 4000 revolutions ≥ 2.00 [-]
  • Or
  • Number of cylinders with emission threshold misfire within 1000 revolutions ≥ 2.00 [-]
  • Emission threshold misfire detected
  • 1000 rev
  • Continuous
  • 2 DCY
-- Check the spark plugs visually.-- Check the intake system visually for leaks.-- Check the fuel pressure. Refer to appropriate repair information.-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .-- Check the Ignition Coils with Power Output Stage --. Refer to Ignition Coils with Power Output Stage --, CHECKING .
  • Number of cylinders with catalyst damaging misfire ≥ 2.00 [-]
  • Catalyst damaging misfire detected
  • 200 rev
  • Continuous
  • Immediate
P0301  Cylinder 1 Misfire Detected Misfire Crankshaft Speed Fluctuation (Single Or Multiple)
  • Catalyst damage misfire:
  • Catalyst damaging misfire rate > 5.20 - 20.83 %
  • Initial engine speed > 550 RPM
  • Engine speed > 550 RPM
  • Engine speed < 6, 848 for DCT:
  • Time after engine start not calibrated
  • Engine load > 1.99 - 37.99 %
  • Depending on ECT @ cylinder head @ start
  • ECT @ cylinder head @ start <= -48° C
  • Then activation if
  • ECT @ cylinder head>= 20° C
  • Or
  • ECT @ cylinder head @ engine start> -48° C
  • And
  • Fuel cut offnot active
  • Or
  • Single fuel cut offnot active
  • Or
  • Number of fade out cylinders< 2.00[-]
  • And
  • Dynamic manifold air pressurenot calibrated[kPa]
  • Dynamic throttle positionnot calibrated
  • And
  • Dynamic of engine loadnot calibrated
  • And
  • Engine not calibrated
  • Engine speednot calibrated[rpm]
  • Dynamic of ignition angle @ idle speed not calibrated[°CRK]
  • Or
  • Dynamic of ignition anglenot calibrated[°CRK]
  • And
  • Rough roadnot detected
  • 200 rev
  • Continuous
  • Immediate
-- Check the spark plugs visually.-- Check the intake system visually for leaks.-- Check the fuel pressure. Refer to appropriate repair information.-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .-- Check the Ignition Coils with Power Output Stage --. Refer to Ignition Coils with Power Output Stage --, CHECKING .
  • Emission threshold misfire within 1000 rev:
  • Emission threshold misfire rate (MR) >= 2.05 %
  • 1, 000 rev
  • Continuous
  • 2 DCY
  • Emission threshold misfire within 4000 rev:
  • Emission threshold misfire rate (MR) > 2.05 %
  • 4 x 1, 000 rev
  • Continuous
P0302  Cylinder 2 Misfire Detected Misfire Crankshaft Speed Fluctuation (Single Or Multiple)
  • Catalyst damage misfire:
  • Catalyst damaging misfire rate > 5.20 - 20.83 %
  • Initial engine speed > 550 RPM
  • Engine speed > 550 RPM
  • Engine speed < 6, 848 for DCT:
  • Time after engine start not calibrated
  • Engine load > 1.99 - 37.99 %
  • Depending on ECT @ cylinder head @ start
  • ECT @ cylinder head @ start <= -48° C
  • Then activation if
  • ECT @ cylinder head>= 20° C
  • Or
  • ECT @ cylinder head @ engine start> -48° C
  • And
  • Fuel cut offnot active
  • Or
  • Single fuel cut offnot active
  • Or
  • Number of fade out cylinders< 2.00[-]
  • And
  • Dynamic manifold air pressurenot calibrated[kPa]
  • Dynamic throttle positionnot calibrated[°TPS/s]
  • And
  • Dynamic of engine loadnot calibrated[%]
  • And
  • Engine not calibrated
  • Engine speednot calibrated[rpm]
  • Dynamic of ignition angle @ idle speednot calibrated[°CRK]
  • Or
  • Dynamic of ignition anglenot calibrated[°CRK]
  • And
  • Rough roadnot detected
  • 200 rev
  • Continuous
  • Immediate
-- Check the spark plugs visually.-- Check the intake system visually for leaks.-- Check the fuel pressure. Refer to appropriate repair information.-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .-- Check the Ignition Coils with Power Output Stage --. Refer to Ignition Coils with Power Output Stage --, CHECKING .
  • Emission threshold misfire within 1000 rev:
  • Emission threshold misfire rate (MR) >= 2.05 %
  • 1, 000 rev
  • Continuous
  • 2 DCY
  • Emission threshold misfire within 4000 rev:
  • Emission threshold misfire rate (MR) > 2.05 %
  • 4 x 1, 000 rev
  • Continuous
P0303  Cylinder 3 Misfire Detected Misfire Crankshaft Speed Fluctuation (Single Or Multiple)
  • Catalyst damage misfire:
  • Catalyst damaging misfire rate > 5.20 - 20.83 %
  • Initial engine speed > 550 RPM
  • Engine speed > 550 RPM
  • Engine speed < 6, 848 for DCT:
  • Time after engine start not calibrated
  • Engine load > 1.99 - 37.99 %
  • Depending on ECT @ cylinder head @ start
  • ECT @ cylinder head @ start <= -48° C
  • Then activation if
  • ECT @ cylinder head>= 20° C
  • Or
  • ECT @ cylinder head @ engine start> -48° C
  • And
  • Fuel cut offnot active
  • Or
  • Single fuel cut offnot active
  • Or
  • Number of fade out cylinders< 2.00[-]
  • And
  • Dynamic manifold air pressurenot calibrated[kPa]
  • Dynamic throttle positionnot calibrated[°TPS/s]
  • And
  • Dynamic of engine loadnot calibrated[%]
  • And
  • Engine not calibrated
  • Engine speednot calibrated[rpm]
  • Dynamic of ignition angle @ idle speednot calibrated[°CRK]
  • Or
  • Dynamic of ignition anglenot calibrated[°CRK]
  • And
  • Rough roadnot detected
  • 200 rev
  • Continuous
  • Immediate
-- Check the spark plugs visually.-- Check the intake system visually for leaks.-- Check the fuel pressure. Refer to appropriate repair information.-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .-- Check the Ignition Coils with Power Output Stage --. Refer to Ignition Coils with Power Output Stage --, CHECKING .
  • Emission threshold misfire within 1000 rev:
  • Emission threshold misfire rate (MR) >= 2.05 %
  • 1, 000 rev
  • Continuous
  • 2 DCY
  • Emission threshold misfire within 4000 rev:
  • Emission threshold misfire rate (MR) > 2.05 %
  • 4 x 1, 000 rev
  • Continuous
P0304  Cylinder 4 Misfire Detected Misfire Crankshaft Speed Fluctuation (Single Or Multiple)
  • Catalyst damage misfire:
  • Catalyst damaging misfire rate > 5.20 - 20.83 %
  • Initial engine speed > 550 RPM
  • Engine speed > 550 RPM
  • Engine speed < 6, 848 for DCT:
  • Time after engine start not calibrated
  • Engine load > 1.99 - 37.99 %
  • Depending on ECT @ cylinder head @ start
  • ECT @ cylinder head @ start <= -48° C
  • Then activation if
  • ECT @ cylinder head>= 20° C
  • Or
  • ECT @ cylinder head @ engine start> -48° C
  • And
  • Fuel cut offnot active
  • Or
  • Single fuel cut offnot active
  • Or
  • Number of fade out cylinders< 2.00[-]
  • And
  • Dynamic manifold air pressurenot calibrated[kPa]
  • Dynamic throttle positionnot calibrated[°TPS/s]
  • And
  • Dynamic of engine loadnot calibrated[%]
  • And
  • Engine not calibrated
  • Engine speednot calibrated[rpm]
  • Dynamic of ignition angle @ idle speednot calibrated[°CRK]
  • Or
  • Dynamic of ignition anglenot calibrated[°CRK]
  • And
  • Rough roadnot detected
  • 200 rev
  • Continuous
  • Immediate
-- Check the spark plugs visually.-- Check the intake system visually for leaks.-- Check the fuel pressure. Refer to appropriate repair information.-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .-- Check the Ignition Coils with Power Output Stage --. Refer to Ignition Coils with Power Output Stage --, CHECKING .
  • Emission threshold misfire within 1000 rev:
  • Emission threshold misfire rate (MR) >= 2.05 %
  • 1, 000 rev
  • Continuous
  • 2 DCY
  • Emission threshold misfire within 4000 rev:
  • Emission threshold misfire rate (MR) > 2.05 %
  • 4 x 1, 000 rev
  • Continuous
P0326 Knock/Combustion Vibration Sensor 1 Circuit Range/Performance Bank 1 or Single Sensor Knock Sensor Rationality Check Low
  • Difference between knock sensor signal and average knock sensor signal < 0.00 - 0.12 V
  • ECT @ cylinder head > 59° C
  • MAF > 229.00 mg/rev
  • 4.3 s
  • Continuous
  • 2 DCY
-- Check the Knock Sensor 1 -G61-. Refer to Knock Sensor 1 - G61-, CHECKING .
P0327 Knock/Combustion Vibration Sensor 1 Circuit Low Bank 1 or Single Sensor Knock Sensor Out Of Range
  • Sensor signal < 0.12 - 0.31 V
  • ECT @ cylinder head > 59° C
  • MAF > 229.00 mg/rev
  • Engine speed > 2, 016 RPM
  • 4.0 s
  • Continuous
  • 2 DCY
-- Check the Knock Sensor 1 -G61-. Refer to Knock Sensor 1 - G61-, CHECKING .
P0335 Crankshaft Position Sensor "A" Circuit Crankshaft Position Sensor Activity Check
  • Case 1:
  • Counted exhaust camshaft signals without synchronization >= 17.00 [-]
  • Or
  • Counted intake camshaft signals without synchronization >= 17.00 [-]
  • Case 2:
  • Counted exhaust camshaft signals without synchronization n.a. [-]
  • Or
  • Counted intake camshaft signals without synchronization n.a. [-]
  • Signal edges @ selected camshaft signal detected
  • Choice of:
  • Ignition off
  • Engine speed > 380 RPM
  • Engine stalling >= 1.0 s
  • Or
  • Synchronization test incorrect
  • Or
  • Engine speed >= 380 RPM
  • Or
  • Engine running
  • Engine stalling >= 5.0 s
  • Or
  • Backwards rotation not detected
  • Or
  • Engine speed >= 400 RPM
  • Engine stop active
  • 0.01 s
  • Continuous
  • 2 DCY
-- Check the Camshaft Position Sensor -G40-. Refer to Camshaft Position Sensor -G40-, CHECKING .
P0336 Crankshaft Position Sensor "A" Circuit Range/Performance RPM Sensor Out Of Range
  • Segment adaptation >= 0.70 %
  • Delay time>= 5, 760.00° CRK
  • And
  • Diff. actual air mass vs. previous air mass<= 20.01 - 39.99mg/rev
  • Engine load<= 20.00 %
  • Dynamic throttle position<= 269.50 - 398.40° TPS/s
  • Rough roadnot detected
  • Engine roughness signalnot valid
  • Segments in fuel cut-off mode>= 32.00[-]
  • Segment adaptationfinished
  • Engine speed 2, 496 - 5, 024rpm
  • Diff. between adapted value of cylinder 1 and cylinder 3< 0.70 %
  • Diff. between adapted value of cylinder 2 and cylinder 4< 0.70 %
  • 180.0° CRK
  • Continuous
  • 2 DCY
-- Check the Engine Speed Sensor -G28-. Refer to Camshaft Position Sensor -G40-, CHECKING .
  • Counted teeth vs reference >= 1; <= 2 [-]
  • Engine running
  • 3, 600.0° CRK
  • Continuous
Crankshaft Position Sensor Rationality Check
  • Case 1:
  • Engine speed > 3000 RPM
  • Time between falling signal edges < 50 - 62.5 μs
  • Case 2:
  • Engine speed <= 3000 RPM
  • Time between signal edges < 30 μs
  • Engine speed >= 400 RPM
  • 4, 5720.0° CRK
  • Continuous
Crankshaft Position Sensor Rationality Check
  • Crankshaft reference gap not detected
  • General conditions:
  • Reference gap of reluctor wheel detected
  • And
  • Case 1:
  • Ignition off
  • Engine speed > 380 RPM
  • Engine stalling >= 1.0 s
  • Or
  • Case 2:
  • Engine speed >= 380 RPM
  • Or
  • Engine running
  • And
  • Engine stalling >= 5.0 s
  • Or
  • Case 3:
  • Backwards rotation not detected
  • Or
  • Case 4:
  • Engine speed >= 400 RPM
  • Engine stopped
  • 2, 160° CRK
  • Continuous
Crankshaft Position Sensor Rationality Check
  • Counted teeth vs. reference >= 1; <= 2 [-]
  • General conditions:
  • Engine speed> 320RPM
  • And
  • Case 1:
  • Ignition off
  • Engine speed > 380 RPM
  • Engine stalling >= 1.0 s
  • Or
  • Case 2:
  • Engine speed >= 380 RPM
  • Or
  • Engine running
  • And
  • Engine stalling >= 5.0 s
  • Or
  • Case 3:
  • Backwards rotation not detected
  • Or
  • Case 4:
  • Engine speed >= 400 RPM
  • Engine stopped
  • 1, 800° CRK
  • Continuous
P0340 Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Camshaft Position Sensor Intake Signal Activity Check
  • No change on signal >= 3 [-]
  • Engine speed >= 400 RPM
  • 4, 680.0° CRK
  • Continuous
  • 2 DCY
-- Check the Camshaft Position Sensor -G40-. Refer to Camshaft Position Sensor -G40-, CHECKING .
P0341 Camshaft Position Sensor "A" Circuit Range/Performance Bank 1 or Single Sensor Camshaft Position Sensor Intake Rationality Check
  • Ratio between measured segment time ratio and specified camshaft angle ratio > 2.75 [-]
  • Or
  • Ratio between measured segment time ratio and specified camshaft angle ratio < 0.36 [-]
  • Or
  • Offset between camshaft and crankshaft < -79.0° CRK
  • Or
  • Offset between camshaft and crankshaft > 15.0° CRK
  • Engine speed 400 - 8, 160 RPM
  • 990.0° CRK
  • Continuous
  • 2 DCY
-- Check the Camshaft Position Sensor -G40-. Refer to Camshaft Position Sensor -G40-, CHECKING .
Camshaft Position Sensor Intake Signal Activity Check
  • Segment time value < 50 [μs]
  • 1, 440.0° CRK
  • Continuous
Camshaft Position Sensor Intake Angular Offset Check
  • Offset between camshaft and crankshaft < -79.00; OR > 15.0° CRK
  • Engine synchronization not validated
  • Failure by exhaust camshaft sensor detected
  • 450.0° CRK
  • Once / DCY
P0365 Camshaft Position Sensor "B" Circuit Bank 1 Camshaft Position (CMP) Exhaust Sensor
  • No change on signal>= 3[-]
  • Engine speed >= 400rpm
  • 1080.00° CRK
  • Continuous
  • 2 DCY
-- Check the Camshaft Position Sensor 3 -G300-. Refer to Camshaft Position Sensor 3 - G300-, CHECKING
P0366 Camshaft Position Sensor "B" Circuit Range/Performance Bank 1 Camshaft Position (CMP) Exhaust Sensor rationality check
  • Ratio between measured segment time ratio and specified camshaft angle ratio> 2.75[-]
  • Or
  • Ratio between measured segment time ratio and specified camshaft angle ratio< 0.36[-]
  • Or
  • Offset between camshaft and crankshaft< -24.00° CRK
  • Or
  • Offset between camshaft and crankshaft> 49.00° CRK
  • Engine speed400 - 8, 160rpm
  • 990.00° CRK
  • Continuous
  • 2 DCY
-- Check the Camshaft Position Sensor 3 -G300-. Refer to Camshaft Position Sensor 3 - G300-, CHECKING
Camshaft Position (CMP) Exhaust Sensor signal activity check
  • Segment time value< 50[μs]
  • Engine speed400 - 8, 160 rpm
  • 1440.00° CRK
  • Continuous
  • 2 DCY
Camshaft Position / Crankshaft Position (CMP/CKP) Exhaust Sensor out of range
  • Offset between camshaft and crankshaft< -24.00° CRK
  • Or
  • Offset between camshaft and crankshaft> 49.00° CRK
  • Engine synchronization via crankshaft and camshaftnot finished
  • Or
  • Engine synchronization via crankshaft and camshaftlost
  • 450.00° CRK
  • Once / DCY"
  • 2 DCY
P039B Cylinder 1 Pressure Too High Knock Control Function Check
  • Slow detection:
  • Ratio between knock sensor and knock threshold in main knock window > 2.00 - 3.00 [-]
  • For time >= 9, 000.0 - 11, 700.0° CRK
  • Or
  • Ratio between knock sensor and noise level in pre knock window > 3.50 - 5.00 [-]
  • For time >= 5, 760.0 - 6, 840.0° CRK
  • Or
  • Ratio between knock sensor and noise level in pre knock window > 3.50 - 5.00 [-]
  • Ratio between knock sensor and knock threshold in main knock window > 2.00 - 3.00 [-]
  • For time >= 12, 960.0 - 16, 740.0° CRK
  • Or
  • Torque limitation factor < 0.90 [-]
  • Engine running
  • ECT @ cylinder head > 59° C
  • Engine speed 1, 216 - 6, 720 RPM
  • Engine load n.a. %
  • Mass air flow > 501.00 - 599.00 mg/rev
  • Dynamic engine speed not active
  • Delay time 0.00 sec
  • 900.0° CRK
  • Continuous
  • 2 DCY
-- Check the Knock Sensor 1 -G61-. Refer to Knock Sensor 1 - G61-, CHECKING .
  • Fast detection:
  • Ratio between knock sensor and knock threshold in main knock window > 1.50 - 2.50 [-]
  • For time >= 540.0° CRK
  • Or
  • Ratio between knock sensor and noise level in pre knock window > 2.75 - 4.50 [-]
  • For time >= 360.0° CRK
  • Case 1:
  • ratio between filtered engine roughness and misfire detection threshold <= 0.41 - 0.59 [-]
  • Or
  • Case 2:
  • Ratio between normalized engine roughness and misfire detection threshold <= n.a. [-]
  • Or
  • Case 3:
  • Ratio between filtered engine roughness and misfire detection threshold <= n.a. [-]
  • Or
  • Ratio between normalized engine roughness and misfire detection threshold <= n.a. [-]
P03A5 Cylinder 2 Pressure Too High Knock Control Function Check
  • Slow detection:
  • Ratio between knock sensor and knock threshold in main knock window > 2.00 - 3.00 [-]
  • For time >= 9, 000.0 - 11, 700.0° CRK
  • Or
  • Ratio between knock sensor and noise level in pre knock window > 3.50 - 5.00 [-]
  • For time >= 5, 760.0 - 6, 840.0° CRK
  • Or
  • Ratio between knock sensor and noise level in pre knock window > 3.50 - 5.00 [-]
  • Ratio between knock sensor and knock threshold in main knock window > 2.00 - 3.00 [-]
  • For time >= 12, 960.0 - 16, 740.0° CRK
  • Or
  • Torque limitation factor < 0.90 [-]
  • Engine running ECT @ cylinder head > 60° C
  • Engine speed 1, 216 - 6, 400 RPM
  • Engine load n.a. %
  • Mass air flow > 403.00 - 447.00 mg/rev
  • Dynamic engine speed not active
  • 900.0° CRK
  • Continuous
  • 2 DCY
-- Check the Knock Sensor 1 -G61-. Refer to Knock Sensor 1 - G61-, CHECKING .
  • Fast detection:
  • Ratio between knock sensor and knock threshold in main knock window > 1.50 - 2.50 [-]
  • For time >= 540.0° CRK
  • Or
  • Ratio between knock sensor and noise level in pre knock window > 2.75 - 4.50 [-]
  • For time >= 360.0° CRK
  • Case 1:
  • ratio between filtered engine roughness and misfire detection threshold <= 0.41 - 0.59 [-]
  • Or
  • Case 2:
  • Ratio between normalized engine roughness and misfire detection threshold <= n.a. [-]
  • Or
  • Case 3:
  • Ratio between filtered engine roughness and misfire detection threshold <= n.a. [-]
  • Or
  • Ratio between normalized engine roughness and misfire detection threshold <= n.a. [-]
P03AF Cylinder 3 Pressure Too High Knock Control Function Check
  • Slow detection:
  • Ratio between knock sensor and knock threshold in main knock window > 2.00 - 3.00 [-]
  • For time >= 9, 000.0 - 11, 700.0° CRK
  • Or
  • Ratio between knock sensor and noise level in pre knock window > 3.50 - 5.00 [-]
  • For time >= 5, 760.0 - 6, 840.0° CRK
  • Or
  • Ratio between knock sensor and noise level in pre knock window > 3.50 - 5.00 [-]
  • Ratio between knock sensor and knock threshold in main knock window > 2.00 - 3.00 [-]
  • For time >= 12, 960.0 - 16, 740.0° CRK
  • Or
  • Torque limitation factor < 0.90 [-]
  • Engine running ECT @ cylinder head > 60° C
  • Engine speed 1, 216 - 6, 400 RPM
  • Engine load n.a. %
  • Mass air flow > 403.00 - 447.00 mg/rev
  • Dynamic engine speed not active
  • 900.0° CRK
  • Continuous
  • 2 DCY
-- Check the Knock Sensor 1 -G61-. Refer to Knock Sensor 1 - G61-, CHECKING .
  • Fast detection:
  • Ratio between knock sensor and knock threshold in main knock window > 1.50 - 2.50 [-]
  • For time >= 540.0° CRK
  • Or
  • Ratio between knock sensor and noise level in pre knock window > 2.75 - 4.50 [-]
  • For time >= 360.0° CRK
  • Case 1:
  • ratio between filtered engine roughness and misfire detection threshold <= 0.41 - 0.59 [-]
  • Or
  • Case 2:
  • Ratio between normalized engine roughness and misfire detection threshold <= n.a. [-]
  • Or
  • Case 3:
  • Ratio between filtered engine roughness and misfire detection threshold <= n.a. [-]
  • Or
  • Ratio between normalized engine roughness and misfire detection threshold <= n.a. [-]
P03B9 Cylinder 4 Pressure Too High Knock Control Function Check
  • Slow detection:
  • Ratio between knock sensor and knock threshold in main knock window > 2.00 - 3.00 [-]
  • For time >= 9, 000.0 - 11, 700.0° CRK
  • Or
  • Ratio between knock sensor and noise level in pre knock window > 3.50 - 5.00 [-]
  • For time >= 5, 760.0 - 6, 840.0° CRK
  • Or
  • Ratio between knock sensor and noise level in pre knock window > 3.50 - 5.00 [-]
  • Ratio between knock sensor and knock threshold in main knock window > 2.00 - 3.00 [-]
  • For time >= 12, 960.0 - 16, 740.0° CRK
  • Or
  • Torque limitation factor < 0.90 [-]
  • Engine running ECT @ cylinder head > 60° C
  • Engine speed 1, 216 - 6, 400 RPM
  • Engine load n.a. %
  • Mass air flow > 403.00 - 447.00 mg/rev
  • Dynamic engine speed not active
  • 900.0° CRK
  • Continuous
  • 2 DCY
-- Check the Knock Sensor 1 -G61-. Refer to Knock Sensor 1 - G61-, CHECKING .
  • Fast detection:
  • Ratio between knock sensor and knock threshold in main knock window > 1.50 - 2.50 [-]
  • For time >= 540.0° CRK
  • Or
  • Ratio between knock sensor and noise level in pre knock window > 2.75 - 4.50 [-]
  • For time >= 360.0° CRK
  • Case 1:
  • ratio between filtered engine roughness and misfire detection threshold <= 0.41 - 0.59 [-]
  • Or
  • Case 2:
  • Ratio between normalized engine roughness and misfire detection threshold <= n.a. [-]
  • Or
  • Case 3:
  • Ratio between filtered engine roughness and misfire detection threshold <= n.a. [-]
  • Or
  • Ratio between normalized engine roughness and misfire detection threshold <= n.a. [-]
P0410  AIR System "A" Secondary Air System Functional Check
  • Diff. pressure value after secondary air injection vs. pressure value before secondary air activation > 5.0 kPa
  • General:
  • Secondary air pump ready
  • Catalyst heating active
  • Secondary air injection finished
  • MAF <= 140.0 kg/h
  • ECT @ cylinder head >= -10; < 115° C
  • IAT @ manifold >= -10; < 100° C
  • Modeled catalyst temperature < 900° C
  • Relative barometric pressure > 0.73 [-]
  • Diff. barometric pressure vs. manifold pressure > n.a. kPa
  • 0.1 s
  • Once / DCY
  • 2 DCY
-- Check the Secondary Air System -GX24-. Refer to Secondary Air Injection Sensor 1 -G609- / Secondary Air Injection Solenoid Valve -N112-, CHECKING .-- Check the Secondary Air Injection Pump Motor -V101- / Secondary Air Injection Pump Relay -J299-. Refer to Secondary Air Injection Pump Motor -V101- / Secondary Air Injection Pump Relay -J299-, CHECKING .
P0413 AIR System Switching Valve "A" Circuit Open Secondary Air Valve Open Circuit
  • Output voltage, lower range >= 1.92 - 2.21 V
  • Output voltage, upper range (hardware values) <= 2.85 - 3.25 V
  • Engine running
  • Actuator commanded off
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the Secondary Air System -GX24-. Refer to Secondary Air Injection Sensor 1 -G609- / Secondary Air Injection Solenoid Valve -N112-, CHECKING .
P0414 AIR System Switching Valve "A" Circuit Shorted Secondary Air Valve Short To Ground
  • Output voltage (hardware values) < 1.92 - 2.21 V
  • Engine running
  • Actuator commanded off
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the Secondary Air System -GX24-. Refer to Secondary Air Injection Sensor 1 -G609- / Secondary Air Injection Solenoid Valve -N112-, CHECKING .
Secondary Air Valve Short To Battery Plus
  • Actuator temperature > 160 - 200° C
  • Or
  • Output current (hardware values) driver stage internal value
  • Engine running
  • Actuator commanded on
P0418 AIR System Control "A" Circuit Secondary Air Injection Pump Relay Open Circuit
  • Output voltage, lower range 1.92 - 2.21 V
  • Output voltage, upper range (hardware values) <= 2.85 - 3.25 V
  • Engine running
  • Actuator commanded off
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the Secondary Air Injection Pump Motor -V101- / Secondary Air Injection Pump Relay -J299-. Refer to Secondary Air Injection Pump Motor -V101- / Secondary Air Injection Pump Relay -J299-, CHECKING .
P0420  Catalyst System Efficiency Below Threshold Bank 1 NMOG / NMHC Conversion Capability
  • Catalyst efficiency > 1.00 [-]
  • Catalyst monitor lambda modulation request active
  • General conditions:
  • Vehicle speed >= 19 mph
  • BARO >= 0.00 kPa
  • Catalyst overheating protection not active
  • Turbine overheating protection not active
  • O2S rear ready
  • O2S front ready
  • ECT @ cylinder head > 60° C
  • IAT@ manifold > -48° C
  • modeled catalyst temperature @ start of diagnosis> 510° C
  • Modeled catalyst temperature @ during diagnosis 470 - 830° C
  • Difference between dynamic and stationary catalyst temperature -150 - 150° C
  • Integrated MAF, catalyst temp. conditions fulfilled >= 0.0 g
  • Modeled EGT @ O2S rear <= 900° C
  • MAF per cylinder 22.50 - 150.00 kg/h
  • Air mass, lower range >= 0.00 mg/rev
  • Air mass, upper range <= 650.00 - 1, 389.00 mg/rev
  • And
  • Engine loadn.a.[%]
  • Air mass setpointn.a.[g/rev]
  • Accelerator pedal valuen.a.[%]
  • For timen.a.[s]
  • And
  • Low dynamic conditions
  • Dynamic engine speed< 50 rpm
  • Dynamic air mass< 50.00 mg/rev
  • Dynamic lambda controller output< 20.00 %
  • And
  • Integrated air mass after dynamic conditions are fulfilled> 20.0 g
  • Time after a catalyst purge phase>= 1.0s
  • O2S rear voltage @ diagnosis start>= 0.55V
  • Integrated air mass>= 0.0 g
  • Integrated heat energy>= 550.00 - 700.00 kJ
  • Engine speed1, 088 - 3, 008rpm
  • Deviation of lambda controller output< 50.00 %
  • Proportional part of secondary fuel control loopnot calibrated %
  • Coasting functionnot active
  • O2S heater rearactive
  • Lambda adaptationnot active
  • Valve lift not active
  • And
  • Depending on Lambda control:
  • Sum of integral and proportional part of secondary fuel control loop before diagnosis< 0.10 [-]
  • Or
  • Sum of integral and proportional part of secondary fuel control loop during diagnosis< 0.25 [-]
  • Depending on canister purge:
  • Canister loadn.a.[-]
  • Evap purge flown.a.
  • Or
  • Canister load calculationn.a.
  • Evap purge flow n.a.
  • Or
  • Evap purge valven.a.
  • Or
  • Evap purge valven.a.
  • Or
  • Evap purgen.a.
  • Or
  • Depending on canister purge closing:
  • Canister purge (conditions)n.a.
  • Canister purge valve (closing time)n.a.[s]
  • And
  • Choice of:
  • Evap purge valven.a.
  • Or
  • Evap purge valven.a.
  • And
  • Modeled air mass integral> 50.0g
  • Integrated air mass per cylinder>= 1.45 - 1.70kg
  • Internal resistance O2S rear<= 700.00 Ohm
  • 60.0 - 70.0 s
  • Once / DCY
  • 1 DCY
-- Check the Three Way Catalytic Converter. Refer to appropriate repair information.-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter -GX7-, CHECKING .
P0441  EVAP System Incorrect Purge Flow EVAP Purge ValveFunctional Check: Stuck Close
  • Ratio actual intake manifold pressure and modeled set point intake manifold pressure < 0.10[-]
  • ECT @ cylinder head > 60° C
  • Barometric pressure > 73.0 kPa
  • AAT > 5° C
  • AAT @ start< 5° C
  • Diff. barometric pressure vs. filtered intake manifold pressuren.a.
  • Diff. barometric pressure vs. filtered intake manifold pressure> 28.00 kPa
  • Ratio MAF @ intake manifold and MAF max. > 0.07 - 0.10[-]
  • Engine speed1, 180 - 2, 800 RPM
  • Vehicle speed >= 11mph
  • Diff. engine speed vs. filtered engine speed< 90 RPM
  • Diff. ratio MAF @ intake manifold and MAF max vs. ratio filtered MAF @ intake manifold and MAF max< 0.15 [-]
  • Diff. modeled intake manifold pressure vs. filtered modeled intake manifold pressure < 1.50 - 2.50 kPa
  • And
  • Integrated MAF since engine start >= 0.0 - 5, 000.0g
  • Lambda control active
  • Lambda control value -30.00 - 30.00 %
  • O2S front 0.90 - 1.10 [-]
  • or
  • Fuel cut off not calibrated
  • Case 1:
  • Integrated MAF @ canister purge per driving cycle>= n.a. g
  • Case 2:
  • ratio MAF @ canister purge and MAF per cylinder>= 0.00[-]
  • Or
  • Canister purge sampling rate>= 20.00 %
  • And
  • Integrated air mass @ canister purge valve>= 31.9g
  • Depending on AAT:
  • AAT>= 30° C
  • Canister load <= 0.20 [-]
  • Or
  • AAT>= 50; < 30° C
  • Canister load <= 0.20 [-]
  • Or
  • AAT < 50° C
  • Canister load <= 0.20 [-]
  • 8.5 s
  • Once / DCY
  • 2 DCY
-- Check the EVAP Canister Purge Regulator Valve 1 -N80-. Refer to EVAP Canister Purge Regulator Valve 1 -N80-, CHECKING .
P0444 EVAP System Purge Control Valve "A" Circuit Open EVAP Purge Valve Open Circuit
  • Output voltage, lower range >= 1.92 - 2.21 V
  • Output voltage, upper range (hardware values) <= 2.85 - 3.25 V
  • Engine start not active
  • Engine running
  • Evap purge valve opening signal (PWM) > 3.13; <= 98.83 %
  • Actuator commanded off
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the EVAP Canister Purge Regulator Valve 1 -N80-. Refer to EVAP Canister Purge Regulator Valve 1 -N80-, CHECKING .
P0445 EVAP System Purge Control Valve "A" Circuit Shorted EVAP Purge Valve Short To Ground
  • Output voltage (hardware values) 1.92 - 2.21 V
  • Engine start not active
  • Engine running
  • Evap purge valve opening signal (PWM) <= 98.83 %
  • Actuator commanded off
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the EVAP Canister Purge Regulator Valve 1 -N80-. Refer to EVAP Canister Purge Regulator Valve 1 -N80-, CHECKING .
EVAP Purge Valve Short To Battery Plus
  • Actuator temperature 160 - 200° C
  • Or
  • Output current (hardware values) driver stage internal value
  • Engine start not active
  • Engine running
  • Evap purge valve opening signal (PWM) >= 3.13 %
  • Actuator commanded on
P0450 EVAP System Pressure Sensor/Switch Circuit NVLD Switch Open Circuit
  • Signal voltage 0.39 - 0.55 V
  • Case 1:
  • Engine running
  • Case 2:
  • Ignition off
  • NVLD (EVAP-System) diagnostic mode active
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Fuel Tank Leak Detection Control Module -J909- / Fuel Tank Pressure Sensor -G400-. Refer to Fuel Tank Leak Detection Control Module -J909- / Fuel Tank Pressure Sensor -G400-, CHECKING .
P0451 EVAP System Pressure Sensor/Switch Circuit Range/Performance NVLD Switch Functional Check Stuck Close
  • Natural vacuum leak detection (NVLD) switch position closed
  • Ignition off
  • Fuel level < 85.10 %
  • Fuel temperature increase >= 5 K
  • For time >= 1.0 h
  • AAT >= 4° C
  • Barometric pressure >= 73.0 kPa
  • Time since ignition off > 20; < 1, 440 min
  • 0.1 s
  • Once / DCY
  • 2 DCY
-- Check the Fuel Tank Leak Detection Control Module -J909- / Fuel Tank Pressure Sensor -G400-. Refer to Fuel Tank Leak Detection Control Module -J909- / Fuel Tank Pressure Sensor -G400-, CHECKING .
P0452 EVAP System Pressure Sensor/Switch Circuit Low NVLD Switch Short To Ground
  • Signal voltage < 0.24 V
  • Case 1:
  • Engine running
  • Case 2:
  • Ignition off
  • NVLD (EVAP-System) diagnostic mode active
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Fuel Tank Leak Detection Control Module -J909- / Fuel Tank Pressure Sensor -G400-. Refer to Fuel Tank Leak Detection Control Module -J909- / Fuel Tank Pressure Sensor -G400-, CHECKING .
P0453 EVAP System Pressure Sensor/Switch Circuit High NVLD Switch Short To Battery Plus
  • Signal voltage > 3.0 V
  • Case 1:
  • Engine running
  • Case 2:
  • Ignition off
  • NVLD (EVAP-System) diagnostic mode active
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Fuel Tank Leak Detection Control Module -J909- / Fuel Tank Pressure Sensor -G400-. Refer to Fuel Tank Leak Detection Control Module -J909- / Fuel Tank Pressure Sensor -G400-, CHECKING .
P0456  EVAP System Leak Detected (Very Small Leak) EVAP System Small Leak Functional Check
  • Natural vacuum leak detection (NVLD) switch position = open
  • Ignition off
  • Fuel level < 85.10 %
  • Fuel temperature drop >= 6 K
  • For time > 1 h
  • AAT >= 4° C
  • Barometric pressure > 73.00 kPa
  • Diff. barometric pressure @ stop and barometric pressure @ start < 0.65 kPa
  • Time since ignition off > 90 [min] ; < 600 min
  • 0.1 s
  • Once / DCY
  • 2 DCY
-- Check the EVAP System visually for any leaking hoses or damage to components.-- Check the EVAP Canister Purge Regulator Valve 1 -N80-. Refer to EVAP Canister Purge Regulator Valve 1 -N80-, CHECKING .-- Check the Fuel Tank Leak Detection Control Module -J909- / Fuel Tank Pressure Sensor -G400-. Refer to Fuel Tank Leak Detection Control Module -J909- / Fuel Tank Pressure Sensor -G400-, CHECKING .
P0461 Fuel Level Sensor "A" Circuit Range/Performance Fuel Level Plausibility Check
  • Diff. fuel consumption And Fuel level changes < -25.0; > 12.0 [-]
  • General:
  • Refueling or defuelingnot detected
  • And
  • Case 1:
  • For tank full fuel level > 96.09 %
  • Fuel consumption since last refueling or last plausibility check > 44.0 [-]
  • Case 2:
  • For tank not full fuel level <= 96.09 %
  • Fuel consumption since last refueling or last plausibility check > 15.0 l
  • 1.0 s
  • Multiple
  • 2 DCY
  • Check the Fuel Level Sensor -G-. Refer to appropriate repair information.
P0462 Fuel Level Sensor "A" Circuit Low CAN: Fuel Level Sensor 1 CAN Communication With Instrument Cluster Module
  • Instrument cluster module signal: short to ground failure
 
  • 0.5 s
  • Continuous
  • 2 DCY
  • Check the Fuel Level Sensor -G-. Refer to appropriate repair information.
  • Instrument cluster module signal: signal range check failure
P0463 Fuel Level Sensor "A" Circuit High CAN: Fuel Level Sensor 1 CAN Communication With Instrument Cluster Module
  • Instrument cluster module signal: short to battery / open circuit failure
 
  • 0.5 s
  • Continuous
  • 2 DCY
  • Check the Fuel Level Sensor -G-. Refer to appropriate repair information.
P0491  AIR System Insufficient Flow Bank 1 Secondary Air System Functional Check
  • Case 1:
  • Blockage: ratio relative measured secondary air pressure and modelled secondary air pressure [tube blocked] < 0.70 [-]
  • Or
  • Leakage: ratio relative measured secondary air pressure and modelled secondary air pressure [leak diagnosis] < 0.65 [-]
  • Case 2:
  • Diff. expected integrated secondary air pressure pulsations and actual integrated secondary air pressure pulsations n.a. kPa
  • Case 3:
  • Blockage: ratio relative measured secondary air pressure and modelled secondary air pressure [tube blocked] < 0.40 [-]
  • Or
  • Leakage: ratio relative measured secondary air pressure and modelled secondary air pressure [leak diagnosis] < 0.15 [-]
  • General:
  • Secondary air pump active
  • Catalyst heating active
  • Secondary air injection active
  • MAF <= 140.0 kg/h
  • ECT @ cylinder head >= -10; < 115° C
  • IAT @ manifold >= -10; < 100° C
  • Modelled catalyst temperature < 900° C
  • Relative barometric pressure > 0.73 [-]
  • Diff. barometric pressure vs. manifold pressure > n.a. kPa
  • 0.1 s
  • Once / DCY
  • 2 DCY
-- Check the Secondary Air System -GX24-. Refer to Secondary Air Injection Sensor 1 -G609- / Secondary Air Injection Solenoid Valve -N112-, CHECKING .-- Check the Secondary Air Injection Pump Motor -V101- / Secondary Air Injection Pump Relay -J299-. Refer to Secondary Air Injection Pump Motor -V101- / Secondary Air Injection Pump Relay -J299-, CHECKING .
P0501 Vehicle Speed Sensor "A" Circuit Range/Performance CAN: Vehicle Speed Sensor CAN Communication With Vehicle Speed Sensor
  • Speed sensor fault value: Out of range high failure
 
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Vehicle Speed Signal. Refer to VEHICLE SPEED SIGNAL, CHECKING
  • Speed sensor fault value: Out of range low failure
  • Speed sensor fault value: Rationality check high failure
  • Speed sensor fault value: Rationality check low failure
P0502 Vehicle Speed Sensor "A" Circuit Low Vehicle Speed Sensor (VSS) short to ground
  • Diagnostic signal from output driver failure
 
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Vehicle Speed Signal. Refer to VEHICLE SPEED SIGNAL, CHECKING
Vehicle Speed Sensor (VSS) open circuit  
Vehicle Speed Sensor (VSS) short to battery plus  
P0506 Idle Control System RPM - Lower Than Expected Idle Speed Control (ISC) function monitoring: engine speed deviation
  • Diff. actual engine speed vs. engine speed setpoint < -100 RPM
  • Integrated I-part of idle speed controller n.a.
  • General conditions:
  • Vehicle speed=0 mph
  • Accelerator pedalreleased by driver
  • Throttle actuatorcommanded on
  • Evap purge flow< 4.00 kg/h
  • Enginerunning
  • Time after engine start> 0.0s
  • Clutch switchn.a.
  • Barometric pressure> 70.00kPa
  • Catalyst heatingnot active
  • ECT @ cylinder head> -48° C
  • And
  • Setpoint changen.a.rpm
  • For timen.a. s
  • And
  • Additional after dynamic conditions fulfilled:
  • Gear switchnot active
  • (A/T only)
  • Accelerator pedalreleased by driver
  • Vehicle speed 0mph
  • Engine load< 31.25%
  • (M/T only)
  • For time>= 0.0 s
  • 12.0 s
  • Continuous
  • 2 DCY
-- Check the Throttle Valve Control Module -GX3-. Refer to Throttle Valve Control Module -GX3-, CHECKING .
P0507 Idle Control System RPM - Higher Than Expected Idle Speed Control (ISC) function monitoring: engine speed deviation
  • Diff. actual engine speed vs. engine speed setpoint > 90 RPM
  • Integrated I-part of idle speed controller n.a.
  • General conditions:
  • Vehicle speed=0 mph
  • Accelerator pedalreleased by driver
  • Throttle actuatorcommanded on
  • Evap purge flow< 4.00 kg/h
  • Enginerunning
  • Time after engine start> 0.0 s
  • Clutch switchn.a.
  • Barometric pressure> 70.00kPa
  • Catalyst heatingnot active
  • ECT @ cylinder head> -48° C
  • And
  • Setpoint changen.a.rpm
  • For timen.a. s
  • And
  • Additional after dynamic conditions fulfilled:
  • Gear switchnot active
  • (A/T only)
  • Accelerator pedalreleased by driver
  • Vehicle speed0 mph
  • (M/T only)
  • For time>= 0.0 s
  • 12 s
  • Continuous
  • 2 DCY
-- Check the Throttle Valve Control Module -GX3-. Refer to Throttle Valve Control Module -GX3-, CHECKING .
P050A Cold Start Idle Control System Performance Cold Idle Controller Function Monitoring: engine speed deviation
  • Positive engine speed vs. engine speed set point > 90 RPM
  • Integrated I-part of idle speed controller n.a.
  • General conditions:
  • Vehicle speed=0 mph
  • Accelerator pedalreleased by driver
  • Throttle actuatorcommanded on
  • Evap purge flow< 4.00 kg/h
  • Enginerunning
  • Time after engine start> 0.0 s
  • Clutch switchn.a.
  • Barometric pressure> 70.00kPa
  • Catalyst heatingactive
  • ECT @ cylinder head> -10° C
  • And
  • Setpoint changen.a.rpm
  • For timen.a.s
  • And
  • Additional after dynamic conditions fulfilled:
  • Gear switchnot active
  • (A/T only)
  • Accelerator pedalreleased by driver
  • Vehicle speed0mph
  • For time>= 0.0s
  • 12 s
  • Continuous
  • 2 DCY
-- Check the Throttle Valve Control Module -GX3-. Refer to Throttle Valve Control Module -GX3-, CHECKING .
Cold Idle Controller Function Monitoring: engine speed deviation
  • Negative engine speed deviation from set point > 100 RPM
  • Integrated I-part of idle speed controller n.a.
  • General conditions:
  • Vehicle speed=0 mph
  • Accelerator pedalreleased by driver
  • Throttle actuatorcommanded on
  • Evap purge flow< 4.00kg/h
  • Enginerunning
  • Time after engine start> 0.0s
  • Clutch switchn.a.
  • Barometric pressure> 70.00kPa
  • Catalyst heatingactive
  • ECT @ cylinder head> -10° C
  • And
  • Setpoint changen.a. rpm
  • For timen.a. s
  • And
  • Additional after dynamic conditions fulfilled:
  • Gear switchnot active
  • (A/T only)
  • Accelerator pedalreleased by driver
  • Vehicle speed0mph
  • Engine load< 31.25%
  • (M/T only)
  • For time>= 0.0 s
P050B Cold Start Ignition Timing Performance Ignition Control Ignition Timing Monitor
  • Ratio between ignition angle efficiency integral and time at idle speed > 0.20 [-]
  • Engine idle speed time @ idle speed > 5.0 s
  • Ignition angle setpoint <= 0.85 [-]
  • Modeled pressure quotient <= 1.0 [-]
  • Vehicle speed = 0 mph
  • And
  • Diff. air mass set point vs. filtered air mass set point for load dynamic detection < 99, 999.00 mg/rev
  • For time >= 0.0 s
  • And
  • Diff. engine speed vs. filtered engine speed for engine speed dynamic detection < 8, 160 RPM
  • For time >= 0.0 s
  • 0.1 s
  • Once / DCY
  • 2 DCY
-- Check for any Engine Speed sensor or Ignition Coil faults and diagnose them first.-- Check the Engine Speed Sensor -G28-. Refer to Engine Speed Sensor -G28-, CHECKING .-- Check the Ignition Coils with Power Output Stage --. Refer to Ignition Coils with Power Output Stage --, CHECKING .-- If NO other codes are set, check the ECM. Refer to appropriate repair information.-- Check the Engine Control Module -J623-. Refer to appropriate repair information.
P052A Cold Start "A" Camshaft Position Timing Over-Advanced Bank 1 Cold Start Monitoring Variable Valve Timing (VVT) Intake Actuator rationality check
  • Camshaft position deviation> 9.00° CRK
  • Modeled oil temperature-40 - 160° C
  • Engine speed608 - 6, 016rpm
  • Camshaft positionn.a.
  • Camshaft position adjustmentactive
  • Catalyst heatingactive
  • Camshaft position deviation integrator (actual vs. setpoint position)>= 8.00° CRK's
  • 0 (FTP75: 45) [s]
  • once / DCY
  • 2 DCY
-- Check the Camshaft Adjustment Valve 1 -N205-. Refer to Camshaft Adjustment Valve 1 -N205-, CHECKING
P053F Cold Start Fuel Pressure Performance Bank 2 Fuel System Out Of Range High
  • Deviation between reference and actual fuel pressure < -2, 999.90 kPa
  • For time >= 3.0 s
  • General:
  • Engine speed> 512 rpm
  • Time after engine start> 10.0 s
  • And
  • Fuel mass setpoint lower range> 5.00 mg/rev
  • for time>= 10.0 s
  • Fuel mass setpoint upper range<= 187.17 - 229.23 mg/rev
  • Fuel mass setpoint gradient-1389.00 - 1389.00 mg/rev
  • For time>= 5.0s
  • And
  • Additional for catalyst heating:
  • Catalyst heatingactive
  • ECT @ cylinder head> -48° C
  • Fuel mass setpoint lower range>= 5.00 mg/rev
  • For time>= 5.1 s
  • 4.5 s
  • Once / DCY
  • 2 DCY
-- Check the fuel pressure. Refer to appropriate repair information.-- Check the Fuel Pump Control Module -J538- / Fuel Delivery Unit -GX1-. Refer to Fuel Pump Control Module -J538- /Fuel Delivery Unit -GX1-, CHECKINGFuel Pressure Regulator Valve -N276-, CHECKING .-- Check the Fuel Pressure Sensor -G247-. Refer to Fuel Pressure Sensor -G247-, CHECKING .
Fuel System Out Of Range Low
  • Deviation between reference and actual fuel pressure > 2, 999.90 kPa
  • For time >= 3.0 s
P054A Cold Start "B" Camshaft Position Timing Over-Advanced Bank 1 Cold Start Monitoring Variable Valve Timing (VVT) Exhaust Actuator rationality check
  • Camshaft position deviation> 9.00° CRK
  • Modeled oil temperature-40...160° C
  • Engine speed 608 - 6, 016 rpm
  • Camshaft positionn.a.
  • Camshaft position adjustmentactive
  • Catalyst heatingactive
  • Camshaft position deviation integrator (actual vs. setpoint position)>= 8.00° CRK's
  • 0 (FTP75: 45) s
  • Once / DCY
  • 2 DCY
-- Check the Exhaust Camshaft Adjustment Valve 1 -N318-. Refer to Exhaust Camshaft Adjustment Valve 1 -N318-, CHECKING
P064A Fuel Pump Control Module COM: Fuel Pump Control Module (FPCM) communication with FPCM
  • FP signal: ROM / RAM failure feedback>= 2.00[-]
  • Engineon
  • 1.2 s Continuous
  • 2 DCY
-- Check the Fuel Pump Control Module -J538- / Fuel Delivery Unit -GX1-. Refer to Fuel Pump Control Module -J538- /Fuel Delivery Unit -GX1-, CHECKING .
  • FP signal: power amplifier failure feedback>= 2.00 [-]
  • 1.4 s Continuous
P0601 Internal Control Module Memory Checksum Error ECM: Checksum Verification
  • Calibration checksum incorrect
 
  • 1.0 s
  • Continuous
  • 2 DCY
-- Check the Engine Control Module -J623-. Refer to appropriate repair information.
  • Software checksum incorrect
P0603 Internal Control Module Keep Alive Memory (KAM) Error Injection Valves Supply Voltage Internal Hardware Check
  • Hardware vs. software version check during initialization failure
 
  • 4.9 s
  • Once / DCY
  • 2 DCY
-- Check the Engine Control Module -J623-. Refer to appropriate repair information.
  • Calibration during initialization failure
  • Hardware during initialization failure
  • Time reference from micro controller during initialization failure
  • Time reference from micro controller during initialization missing
  • 2, 880.0° CRK
  • Continuous
  • Communication between micro controller and SDI-Driver power stage failure
  • 2880.0° CRK
  • Continuous
  • Communication between micro controller and SDI-Driver power stage failure
  • 360.0° CRK
  • Once / DCY
ECM: Communication Check
  • Device 1:
  • SPI communication with ATIC failure
  • 2.0 s
  • Continuous
  • Device 2:
  • SPI communication with ATIC failure
  • SPI communication with ATIC failure
P0606 Control Module Processor Barometric Pressure Sensor Rationality Check By Engine Off*
  • Diff. barometric pressure vs. upstream throttle pressure >= 8.50 kPa
  • Or
  • Diff. barometric pressure vs. intake manifold pressure >= 8.50 kPa
  • Case 1:
  • Engine stop during DCY
  • Engine stopped
  • Vehicle speed < 1 mph
  • Case 2:
  • Engine stop at start of DCY
  • Engine stopped
  • Vehicle speed < 1 mph
  • Delay after engine stop >= 5.0 s
  • For time >= 10.0 s
  • 3.0 s
  • Multiple
  • 2 DCY
-- Using scan tool, monitor the Barometric Pressure Sensor, located within the Engine Control Module -J623-.-- Check the Engine Control Module -J623-. Refer to appropriate repair information.
Barometric Pressure Sensor Rationality Check During ECM Keep Alive-Time:*
  • Case 1:
  • Diff. barometric pressure vs. intake manifold pressure>= 8.50 kPa
  • And
  • Diff. barometric pressure vs. upstream throttle pressure>= 8.50 kPa
  • Case 2:
  • Diff. intake manifold pressure vs. intake manifold pressure @ idle or low part loadn.a.kPa
  • Diff. barometric pressure vs. intake manifold pressuren.a. kPa
  • Diff. barometric pressure vs. upstream throttle pressuren.a. kPa
  • Case 3:
  • Diff. upstream throttle pressure @ full or high part load vs. upstream throttle pressuren.a. kPa
  • Diff. barometric pressure vs. intake manifold pressuren.a. kPa
  • Diff. barometric pressure vs. upstream throttle pressuren.a.kPa
  • Diff. upstream throttle pressure vs. intake manifold pressuren.a.kPa
  • Engine stopped
  • Vehicle speed < 1 mph
  • Ignition off
  • Delay time in ECM keep alive-time > 10.0 s
  • Delay after engine stop >= 5.0 s
  • Barometric pressure sensor voltage 0.20 - 4.80 V
  • intake manifold pressure sensor voltage 0.20 - 4.80 V
  • Turbocharger boost pressure sensor voltage 0.20 - 4.80 V
  • 3.0 s
  • Once / DCY
Barometric Pressure Sensor Out Of Range High*
  • Measured barometric pressure > 115.0 kPa
 
  • 5.0 s
  • Continuous
Barometric Pressure Sensor Out Of Range Low*
  • Measured barometric pressure < 45.0 kPa
Knock Control Functional Check*
  • Knock control failure
  • Engine running
  • 6.4 s
  • Continuous
ECM: EEPROM Check*
  • EEPROM information failure
  • Decryption of NVMCrypt failed
  • Finished NVMCrypt integrity error
  • Communication between sample software and production hardware error
  • RAM error detected
  • Monitoring module check failed
 
  • 1.0 s
  • Once / DCY
ECM: Communication Check*
  • SPI communication with ATIC failure
  • Time after ignition on >= 1.0 s
  • 1.0 s
  • Continuous
ECM: A/D Converter Function Monitoring: A/D Converter*
  • Diff. A/D-channel 1 vs. A/D-channel 2 > 0.30 V
 
  • 0.5 s
  • Continuous
ECM: Electronic Throttle Control Module Function Monitoring: Torque*
  • Monitoring of difference between actual and set point torque value engine torque overflow > 45.00 - 350.00 Nm
  • Throttle actuator commanded on
  • 0.5 s
  • Continuous
  • Monitoring of torque difference integration integrated engine torque > 655.35 Nm
  • 0.01 s
  • Continuous
ECM: Electronic Throttle Control Module Function Monitoring: Engine Speed Limitation*
  • Engine speed > 1, 760 RPM
  • Engine speed limitation active
  • Injection active
  • 0.5 s
  • Continuous
ECM: Electronic Throttle Control Module Function Monitoring: A/D Converter*
  • Internal check failed
 
  • 0.5 s
  • Continuous
CAN: Controller controller RAM check *
  • RAM errormemory checksum error
  • Initialization phaseactive
  • Ignitionon
  • 0.2 s
  • Once / DCY
P0607 Control Module Performance Barometric Pressure Sensor Short To Ground
  • Barometric pressure sensor voltage < 0.20 V
 
  • 0.5 s
  • Continuous
  • 2 DCY
-- Using scan tool, monitor the Barometric Pressure Sensor, located within the Engine Control Module -J623-.-- Check the Engine Control Module -J623-. Refer to appropriate repair information.
Barometric Pressure Sensor Short To Battery Plus
  • Barometric pressure sensor voltage > 4.80 V
P0638 Throttle Actuator Control Range/Performance Bank 1 Throttle Actuator Basic Settings Adaptation Value Monitoring
  • Battery voltage <= 9.04 V
  • Throttle adaptation (@ initial start or after detection of throttle exchange or checksum error) active
  • 0.01 s
  • Once Per Lifetime
  • 2 DCY
-- Check the Throttle Valve Control Module -GX3-. Refer to Throttle Valve Control Module -GX3-, CHECKING .
  • Accelerator pedal value > 99.90 %
  • Or
  • Engine speed > 64 RPM
  • Or
  • Vehicle speed > 1 mph
  • Or
  • Modeled IAT @ throttle < 5° C
  • Or
  • ECT @ cylinder head < 5° C
  • Or
  • ECT @ cylinder head > 110° C
  • 0.01 s
  • Once Per Lifetime
  • Actual TPS 1 or 2 voltage - voltage ref. point > 0.07 V
  • Throttle adaptation demanded
  • Accelerator pedal value < 99.90 %
  • Engine speed < 64 RPM
  • Vehicle speed < 1 mph
  • Modeled IAT @ throttle > 5° C
  • ECT @ cylinder head 5 - 110° C
  • 0.01 s
  • Once / DCY
  • Actual TPS - ref. point > 0.503° TPS
  • 0.01 s
  • Once / DCY
Throttle Actuator Basic Settings Monitoring Of Position
  • Actual TPS - ref. point > 0.503° TPS
  • 0.01 s
  • Once Per Lifetime
  • Throttle position sensor 1 voltage < 0.40 V
  • Or
  • Throttle position sensor 2 voltage > 4.60 V
  • Or
  • Throttle position sensor 1 voltage > 0.80 V
  • Or
  • Throttle position sensor 2 voltage < 4.20 V
  • Actual TPS 1 or 2 voltage - voltage ref. point > 0.07 V
  • Actual TPS 1 or 2 voltage - voltage ref. point > 0.25 V
  • Actual TPS - ref. point > 0.503° TPS
  • Actual TPS 1 or 2 voltage - voltage ref. point > 0.07 V
P0642 Sensor Reference Voltage "A" Circuit Low ECM: 5V Supply Voltage Out Of Range Low
  • Analog output 1 supply voltage < 4.62 V
 
  • 0.2 s
  • Continuous
  • 2 DCY
-- If a related sensor voltage code is also set, refer to that sensor for diagnosis first. If no other related codes set, replace the Engine Control Module -J623-. Refer to appropriate repair information.
P0643 Sensor Reference Voltage "A" Circuit High ECM: 5V Supply Voltage Out Of Range High
  • Analog output 1 supply voltage > 5.43 V
 
  • 0.2 s
  • Continuous
  • 2 DCY
-- If a related sensor voltage code is also set, refer to that sensor for diagnosis first. If no other related codes set, replace the Engine Control Module -J623-. Refer to appropriate repair information.
P0652 Sensor Reference Voltage "B" Circuit Low ECM: 5V Supply Voltage Out Of Range Low
  • Analog output 2 supply voltage < 4.62 V
 
  • 0.2 s
  • Continuous
  • 2 DCY
-- If a related sensor voltage code is also set, refer to that sensor for diagnosis first. If no other related codes set, replace the Engine Control Module -J623-. Refer to appropriate repair information.
P0653 Sensor Reference Voltage "B" Circuit High ECM: 5V Supply Voltage Out Of Range High
  • Analog output 2 supply voltage > 5.43 V
 
  • 0.2 s
  • Continuous
  • 2 DCY
-- If a related sensor voltage code is also set, refer to that sensor for diagnosis first. If no other related codes set, replace the Engine Control Module -J623-. Refer to appropriate repair information.
P0657 Actuator Supply Voltage "A" Circuit/Open Supply Voltage Relay Engine Components Open Circuit
  • Output voltage, lower range >= 1.90 - 2.30 V
  • Output voltage, upper range (hardware values) <= 2.80 - 3.20V
  • Relay commanded off
  • 1.0 s
  • Continuous
  • 2 DCY
-- Check the Engine Component Power Supply Relay -J757-. Refer to Engine Component Power Supply Relay -J757-, CHECKING .
P0658 Actuator Supply Voltage "A" Circuit Low Supply Voltage Relay Engine Components Short To Ground
  • Output voltage (hardware values) < 1.90 - 2.30 V
  • Relay commanded off
  • 0.1 s
  • Continuous
  • 2 DCY
-- Check the Engine Component Power Supply Relay -J757-. Refer to Engine Component Power Supply Relay -J757-, CHECKING .
P0659 Actuator Supply Voltage "A" Circuit High Supply Voltage Relay Engine Components Short To Battery Voltage
  • Output current driver stage internal value
  • Or
  • Actuator temperature (hardware values) > 175 - 195° C
  • Relay commanded on
  • 0.1 s
  • Continuous
  • 2 DCY
-- Check the Engine Component Power Supply Relay -J757-. Refer to Engine Component Power Supply Relay -J757-, CHECKING .
P0686 ECM/PCM Power Relay Control Circuit Low Main Relay Rationality Check During Engine Off
  • Sensed circuit voltage > 6.00V
  • Main relaycommanded on
  • For time>= 0.3 s
  • 0.1 s
  • Continuous
  • 2 DCY
-- Check the Motronic Engine Control Module Power Supply Relay -J271-. Refer to Motronic Engine Control Module Power Supply Relay -J271-, CHECKING .
P0687 ECM/PCM Power Relay Control Circuit High Main Relay Rationality Check During Engine Running
  • Sensed circuit voltage < 5.00 V
  • Main relay commanded on
  • For time>= 0.1 s
  • 0.1 s
  • Continuous
  • 2 DCY
-- Check the Motronic Engine Control Module Power Supply Relay -J271-. Refer to Motronic Engine Control Module Power Supply Relay -J271-, CHECKING .
Main Relay Short To Battery Plus
  • Main relay driver temperature > 175 - 195° C
  • Or
  • Main relay output current (hardware values) driver stage internal value
  • Main relay commanded on
  • For time>= 0.4 s
  • 0.2 s
  • Continuous
P0698 Sensor Reference Voltage "C" Circuit Low ECM: 5V Supply Voltage Out Of Range Low
  • Analog output 3 supply voltage < 4.62 V
 
  • 0.2 s
  • Continuous
  • 2 DCY
-- If a related sensor voltage code is also set, refer to that sensor for diagnosis first. If no other related codes set, replace the Engine Control Module -J623-. Refer to appropriate repair information.
P0699 Sensor Reference Voltage "C" Circuit High ECM: 5V Supply Voltage Out Of Range High
  • Analog output 3 supply voltage > 5.43 V
 
  • 0.2 s
  • Continuous
  • 2 DCY
-- If a related sensor voltage code is also set, refer to that sensor for diagnosis first. If no other related codes set, replace the Engine Control Module -J623-. Refer to appropriate repair information.
P11A1 Cam Shift Actuator "A" Cylinder 1 Circuit/Open Variable Valve Lift (VVL) short to ground
  • Output voltage< 1.92 - 2.21V (hardware values)
  • Actuator commanded off
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Cam Adjustment Actuator 1 -F366-. Refer to Cam Adjustment Actuators --, CHECKING
Variable Valve Lift (VVL) open circuit
  • Output voltage, lower range< 1.92 - 2.21V
  • Output voltage, upper range> 2.85 - 3.25V
  • 2 DCY
P11A2 Cam Shift Actuator "A" Cylinder 1 Range/Performance Variable Valve Lift (VVL) rationality check low
  • Actuator feedback signal voltage permanently low[-]
  • Modeled oil temperature< 20° C
  • 6.0 s
  • Continuous
  • 2 DCY
-- Check the Cam Adjustment Actuator 1 -F366-. Refer to Cam Adjustment Actuators --, CHECKING
P11A3 Cam Shift Actuator "B" Cylinder 1 Circuit/Open Variable Valve Lift (VVL) short to ground
  • Output voltage< 1.92 - 2.21V (hardware values)
  • Actuator commanded off
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Cam Adjustment Actuator 2 -F367-. Refer to Cam Adjustment Actuators --, CHECKING
Variable Valve Lift (VVL) open circuit
  • Output voltage, lower range< 1.92 - 2.21V
  • Output voltage, upper range> 2.85 - 3.25V
  • 2 DCY
P11A4 Cam Shift Actuator "B" Cylinder 1 Range/Performance Variable Valve Lift (VVL) rationality check low
  • Actuator feedback signal voltage permanently low[-]
  • Modeled oil temperature< 20° C
  • 6.0 s
  • Continuous
  • 2 DCY
-- Check the Cam Adjustment Actuator 2 -F367-. Refer to Cam Adjustment Actuators --, CHECKING
P11A5 Cam Shift Actuator "A" Cylinder 2 Circuit/Open Variable Valve Lift (VVL) short to ground
  • Output voltage< 1.92 - 2.21V (hardware values)
  • Actuator commanded off
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Cam Adjustment Actuator 3 -F368-. Refer to Cam Adjustment Actuators --, CHECKING
Variable Valve Lift (VVL) open circuit
  • Output voltage, lower range< 1.92 - 2.21V
  • Output voltage, upper range> 2.85 - 3.25V
  • 2 DCY
P11A6 Cam Shift Actuator "A" Cylinder 2 Range/Performance Variable Valve Lift (VVL) rationality check low
  • Actuator feedback signal voltage permanently low[-]
  • Modeled oil temperature< 20° C
  • 6.0 s
  • Continuous
  • 2 DCY
-- Check the Cam Adjustment Actuator 3 -F368-. Refer to Cam Adjustment Actuators --, CHECKING
P11A7 Cam Shift Actuator "B" Cylinder 2 Circuit/Open Variable Valve Lift (VVL) short to ground
  • Output voltage< 1.92 - 2.21V (hardware values)
  • Actuator commanded off
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Cam Adjustment Actuator 4 -F369-. Refer to Cam Adjustment Actuators --, CHECKING
Variable Valve Lift (VVL) open circuit
  • Output voltage, lower range< 1.92 - 2.21V
  • Output voltage, upper range> 2.85 - 3.25V
  • 2 DCY
P11A8 Cam Shift Actuator "B" Cylinder 2 Range/Performance Variable Valve Lift (VVL) rationality check low
  • Actuator feedback signal voltage permanently low[-]
  • Modeled oil temperature< 20° C
  • 6.0 s
  • Continuous
  • 2 DCY
-- Check the Cam Adjustment Actuator 4 -F369-. Refer to Cam Adjustment Actuators --, CHECKING
P11A9 Cam Shift Actuator "A" Cylinder 3 Circuit/Open Variable Valve Lift (VVL) short to ground
  • Output voltage< 1.92 - 2.21V (hardware values)
  • Actuator commanded off
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Cam Adjustment Actuator 5 -F370-. Refer to Cam Adjustment Actuators --, CHECKING
Variable Valve Lift (VVL) open circuit
  • Output voltage, lower range< 1.92 - 2.21V
  • Output voltage, upper range> 2.85 - 3.25V
  • 2 DCY
P11AA Cam Shift Actuator "A" Cylinder 3 Range/Performance Variable Valve Lift (VVL) rationality check low
  • Actuator feedback signal voltage permanently low[-]
  • Modeled oil temperature< 20° C
  • 6.0 s
  • Continuous
  • 2 DCY
-- Check the Cam Adjustment Actuator 5 -F370-. Refer to Cam Adjustment Actuators --, CHECKING
P11AB Cam Shift Actuator "B" Cylinder 3 Circuit/Open Variable Valve Lift (VVL) short to ground
  • Output voltage< 1.92 - 2.21V (hardware values)
  • Actuator commanded off
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Cam Adjustment Actuator 6 -F371-. Refer to Cam Adjustment Actuators --, CHECKING
Variable Valve Lift (VVL) open circuit
  • Output voltage, lower range< 1.92 - 2.21V
  • Output voltage, upper range> 2.85 - 3.25V
  • 2 DCY
P11AC Cam Shift Actuator "B" Cylinder 3 Range/Performance Variable Valve Lift (VVL) rationality check low
  • Actuator feedback signal voltage permanently low[-]
  • Modeled oil temperature< 20° C
  • 6.0 s
  • Continuous
  • 2 DCY
-- Check the Cam Adjustment Actuator 6 -F371-. Refer to Cam Adjustment Actuators --, CHECKING
P11AD Cam Shift Actuator "A" Cylinder 4 Circuit/Open Variable Valve Lift (VVL) short to ground
  • Output voltage< 1.92 - 2.21V (hardware values)
  • Actuator commanded off
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Cam Adjustment Actuator 7 -F372-. Refer to Cam Adjustment Actuators --, CHECKING
Variable Valve Lift (VVL) open circuit
  • Output voltage, lower range< 1.92 - 2.21V
  • Output voltage, upper range> 2.85 - 3.25V
  • 2 DCY
P11AE Cam Shift Actuator "A" Cylinder 4 Range/Performance Variable Valve Lift (VVL) rationality check low
  • Actuator feedback signal voltage permanently low[-]
  • Modeled oil temperature< 20° C
  • 6.0 s
  • Continuous
  • 2 DCY
-- Check the Cam Adjustment Actuator 7 -F372-. Refer to Cam Adjustment Actuators --, CHECKING
P11AF Cam Shift Actuator "B" Cylinder 4 Circuit/Open Variable Valve Lift (VVL) short to ground
  • Output voltage< 1.92 - 2.21V (hardware values)
  • Actuator commanded off
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Cam Adjustment Actuator 8 -F373-. Refer to Cam Adjustment Actuators --, CHECKING
Variable Valve Lift (VVL) open circuit
  • Output voltage, lower range< 1.92 - 2.21V
  • Output voltage, upper range> 2.85 - 3.25V
  • 2 DCY
P11B0 Cam Shift Actuator "B" Cylinder 4 Range/Performance Variable Valve Lift (VVL) rationality check low
  • Actuator feedback signal voltage permanently low[-]
  • Modeled oil temperature< 20° C
  • 6.0 s
  • Continuous
  • 2 DCY
-- Check the Cam Adjustment Actuator 8 -F373-. Refer to Cam Adjustment Actuators --, CHECKING
P11BF Cam Shift Actuator Outlet "A" Cylinder 1 Range/Performance Variable Valve Lift (VVL) short to battery plus
  • Power stage temperature> 160 - 200° C
  • Or
  • Output current driver stage internal value (hardware values)
  • Actuator commanded on
  • 0.1 s
  • Continuous
  • 2 DCY
-- Check the Cam Adjustment Actuator 1 -F366-. Refer to Cam Adjustment Actuators --, CHECKING
P11C0 Cam Shift Actuator Outlet "B" Cylinder 1 Circuit/Open Variable Valve Lift (VVL) short to battery plus
  • Power stage temperature> 160 - 200° C
  • Or
  • Output current driver stage internal value (hardware values)
  • Actuator commanded on
  • 0.1 s
  • Continuous
  • 2 DCY
-- Check the Cam Adjustment Actuator 2 -F367-. Refer to Cam Adjustment Actuators --, CHECKING
P11C1 Cam Shift Actuator Outlet "A" Cylinder 2 Range/Performance Variable Valve Lift (VVL) short to battery plus
  • Power stage temperature> 160 - 200° C
  • Or
  • Output current driver stage internal value (hardware values)
  • Actuator commanded on
  • 0.1 s
  • Continuous
  • 2 DCY
-- Check the Cam Adjustment Actuator 3 -F368-. Refer to Cam Adjustment Actuators --, CHECKING
P11C2 Cam Shift Actuator Outlet "B" Cylinder 2 Circuit/Open Variable Valve Lift (VVL) short to battery plus
  • Power stage temperature> 160 - 200° C
  • Or
  • Output current driver stage internal value (hardware values)
  • Actuator commanded on
  • 0.1 s
  • Continuous
  • 2 DCY
-- Check the Cam Adjustment Actuator 4 -F369-. Refer to Cam Adjustment Actuators --, CHECKING
P11C3 Cam Shift Actuator Outlet "A" Cylinder 3 Range/Performance Variable Valve Lift (VVL) short to battery plus
  • Power stage temperature> 160 - 200° C
  • Or
  • Output current driver stage internal value (hardware values)
  • Actuator commanded on
  • 0.1 s
  • Continuous
  • 2 DCY
-- Check the Cam Adjustment Actuator 5 -F370-. Refer to Cam Adjustment Actuators --, CHECKING
P11C4 Cam Shift Actuator Outlet "B" Cylinder 3 Circuit/Open Variable Valve Lift (VVL) short to battery plus
  • Power stage temperature> 160 - 200° C
  • Or
  • Output current driver stage internal value (hardware values)
  • Actuator commanded on
  • 0.1 s
  • Continuous
  • 2 DCY
-- Check the Cam Adjustment Actuator 6 -F371-. Refer to Cam Adjustment Actuators --, CHECKING
P11C5 Cam Shift Actuator Outlet "A" Cylinder 4 Range/Performance Variable Valve Lift (VVL) short to battery plus
  • Power stage temperature> 160 - 200° C
  • Or
  • Output current driver stage internal value (hardware values)
  • Actuator commanded on
  • 0.1 s
  • Continuous
  • 2 DCY
-- Check the Cam Adjustment Actuator 7 -F372-. Refer to Cam Adjustment Actuators --, CHECKING
P11C6 Cam Shift Actuator Outlet "B" Cylinder 4 Circuit/Open Variable Valve Lift (VVL) short to battery plus
  • Power stage temperature> 160 - 200° C
  • Or
  • Output current driver stage internal value (hardware values)
  • Actuator commanded on
  • 0.1 s
  • Continuous
  • 2 DCY
-- Check the Cam Adjustment Actuator 8 -F373-. Refer to Cam Adjustment Actuators --, CHECKING
P12A1 Fuel Rail Pressure Sensor Inappropriately Low Fuel System Pressure Sensor, High Pressure Side Rationality Check Low
  • Deviation lambda of controller included adaptation< -22.50%
  • and
  • high pressure controller output> 40mg
  • General:
  • Engine speed512 - 6, 816 rpm
  • Fuel mass setpoint5.00 - 1, 389.00mg/rev
  • Time after change to DFInot equippeds
  • Time after engine start> 10.0 s
  • Engine warm-upnot active
  • Catalyst heatingnot active
  • Full loadnot active
  • Catalyst purgenot active
  • Lambda controlclosed loop
  • Evap purge functionality diagnosis not active
  • Fuel pressure setpoint gradient<= 34, 777.60 [kPa
  • And
  • Depending on low dynamic conditions:
  • Fuel mass setpoint lower range> 5.00 mg/rev
  • For time>= 10.0s
  • Fuel mass setpoint upper range< 187.17 - 229.23mg/rev
  • Fuel mass setpoint gradient-1, 389.00 - 1, 389.00 mg/rev
  • For time>= 5.0 s
  • And
  • Depending on canister purge:
  • Canister load<= 1.00[-]
  • Or
  • Evap purge valvenot active or closed
  • 5.0 s
  • Continuous
  • 2 DCY
-- Check the Fuel Pressure Sensor -G247-. Refer to Fuel Pressure Sensor -G247-, CHECKING .-- Check the Fuel Pump Control Module -J538- / Fuel Delivery Unit -GX1-. Refer to Fuel Pump Control Module -J538- /Fuel Delivery Unit -GX1-, CHECKING .-- Check the fuel pressure. Refer to appropriate repair information.
P12A2 Fuel Rail Pressure Sensor Inappropriately High Fuel System Pressure Sensor, High Pressure Side Rationality Check High
  • Deviation lambda of controller included adaptation> 30.00%
  • And
  • High pressure controller output< -35 mg
  • General:
  • Engine speed608 - 6, 816 rpm
  • Fuel mass setpoint5.00 - 1, 389.00 mg/rev
  • Time after change to DFInot equipped s
  • Time after engine start> 10.0 s
  • Engine warm-upnot active
  • Catalyst heatingnot active
  • Full loadnot active
  • Catalyst purgenot active
  • Lambda controlclosed loop
  • Evap purge functionality diagnosis not active
  • Fuel pressure setpoint gradient<= 34, 777.60 [kPa
  • And
  • Depending on low dynamic conditions:
  • Fuel mass setpoint lower range> 5.00 mg/rev
  • For time>= 10.0s
  • Fuel mass setpoint upper range< 187.17 - 229.23mg/rev
  • Fuel mass setpoint gradient-1, 389.00 - 1, 389.00 mg/rev
  • For time>= 5.0 s
  • And
  • Depending on canister purge:
  • Canister load<= 1.00[-]
  • Or
  • Evap purge valvenot active or closed
  • 5.0 s
  • Continuous
  • 2 DCY
-- Check the Fuel Pressure Sensor -G247-. Refer to Fuel Pressure Sensor -G247-, CHECKING .-- Check the Fuel Delivery Unit -GX1-. Refer to Fuel Pump Control Module -J538- /Fuel Delivery Unit -GX1-, CHECKING .-- Check the fuel pressure. Refer to appropriate repair information.
P12A4 Fuel Rail Pump Control Valve Stuck Closed Fuel System Pressure Sensor, High Pressure Side Out Of Range High
  • Deviation between fuel pressure setpoint and current fuel pressure< -2999.90 kPa
  • Deviation lambda of controller included adaption-50.00 - 50.00 %
  • Case 1:
  • High pressure controller output< -45 mg
  • Case 2:
  • Flow control valveopen
  • Mass fuel flow setpoint> 15.01mg/rev
  • General:
  • Engine speed608 - 6, 816 rpm
  • Fuel mass setpoint5.00 - 1, 389.00 mg/rev
  • Time after engine start> 10.0 s
  • Engine warm-upnot calibrated
  • Catalyst heatingnot calibrated
  • Full loadnot calibrated
  • Catalyst purgenot calibrated
  • Lambda controlnot calibrated
  • Evap purge functionality diagnosis not calibrated
  • Fuel pressure setpoint gradient<= 34, 777.60 [kPa
  • And
  • Depending on low dynamic conditions:
  • Fuel mass setpoint lower range> 5.00 mg/rev
  • For time>= 10.0 s
  • Fuel mass setpoint upper range< 187.17 - 229.23mg/rev
  • Fuel mass setpoint gradient-1, 389.00 - 1, 389.00 mg/rev
  • For time>= 5.0 s
  • And
  • Depending on canister purge:
  • Canister loadnot calibrated[-]
  • Or
  • Evap purge valvenot calibrated
  • 5.0 s
  • Continuous
  • 2 DCY
-- Check the Fuel Pressure Sensor -G247-. Refer to Fuel Pressure Sensor -G247-, CHECKING .-- Check the Fuel Delivery Unit -GX1-. Refer to Fuel Pump Control Module -J538- /Fuel Delivery Unit -GX1-, CHECKING .-- Check the fuel pressure. Refer to appropriate repair information.
P13EA Cold Start Ignition Timing Performance Off Idle Ignition Control Ignition Timing Monitor
  • Ratio between ignition angle efficiency integral and time at part load > 0.16 [-]
  • Time @ part load > 5.0 s
  • Ignition angle set point <= 0.94 [-]
  • Engine part load
  • Vehicle speed > 2 mph
  • And
  • Diff. air mass set point vs. filtered air mass set point for load dynamic detection < 99.999.0 mg/rev
  • For time >= 0.0 s
  • And
  • Diff. engine speed vs. filtered engine speed for engine speed dynamic detection < 8, 160 RPM
  • For time >= 0.0 s
  • 0.1 s
  • Once / DCY
  • 2 DCY
-- Check the Engine Speed Sensor -G28-. Refer to Engine Speed Sensor -G28-, CHECKING .-- Check the Ignition Coils with Power Output Stage --. Refer to Ignition Coils with Power Output Stage --, CHECKING .-- Check for any Engine Speed sensor or Ignition Coil faults and diagnose them first.-- If NO other codes are set, check the ECM. Refer to appropriate repair information.
P1545 Throttle Actuator "A" Control Motor Circuit Range/Performance Throttle Actuator Out Of Range
  • Control duty cycle > 98.0 %
  • Throttle position not at min. value
  • Throttle adaptation not active
  • Throttle actuator commanded on
  • 5.0 s
  • Continuous
  • 2 DCY
-- Check the Throttle Valve Control Module -GX3-. Refer to Throttle Valve Control Module -GX3-, CHECKING .
Throttle Actuator Rationality Check
  • Difference between throttle position set point and throttle flap opening angle for electronic throttle control > 2.998 - 24.982° TPS
  • Throttle adaptation (@ initial start or after detection of throttle exchange or checksum error) not active
  • Throttle actuator commanded on
  • Difference between throttle position set point and throttle flap opening angle <= 1.999; > -1.999° TPS
P169A Loading Mode Active ECM: Transport Mode Function Monitoring: Mode Change
  • Transport mode active
  • Vehicle speed < 3 mph
  • Max trip mileage since initial vehicle start-up < 62.15 miles
  • During ECM keep alive-time after ignition off engine speed 0 RPM
  • Production mode not active
  • For hybrid:
  • Drive motor off
  • 0.01 s
  • Continuous
  • 1 DCY
-- Perform readiness check. Refer to READINESS CODES .
P2004 Intake Manifold Runner Control Stuck Open Bank 1 Intake Manifold Runner Flap Actuator Stuck Open
  • Signal voltage > 1.89 V
  • For time >= 1.5 s
  • Flap commanded off
  • Time after engine start > 5.0 s
  • 0.2 s
  • Continuous
  • 2 DCY
-- Check the Intake Manifold Runner Control Valve -N316-. Refer to Intake Manifold Runner Control Valve -N316-, CHECKING .
P2006 Intake Manifold Runner Control Stuck Closed Bank 1 Intake Manifold Runner Flap Actuator Stuck Close
  • Signal voltage < 3.10 V
  • For time >= 1.5 s
  • Flap commanded on
  • Time after engine start > 5.0 s
  • 0.2 s
  • Continuous
  • 2 DCY
-- Check the Intake Manifold Runner Control Valve -N316-. Refer to Intake Manifold Runner Control Valve -N316-, CHECKING .
P2008 Intake Manifold Runner Control Circuit/Open Bank 1 Intake Manifold Runner Flap Actuator Open Circuit
  • Output voltage lower range 1.92 - 2.21 V
  • Output voltage upper range (hardware values) 2.85 - 3.25 V
  • Engine running
  • Actuator commanded off
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the Intake Manifold Runner Control Valve -N316-. Refer to Intake Manifold Runner Control Valve -N316-, CHECKING .
P2009 Intake Manifold Runner Control Circuit Low Bank 1 Intake Manifold Runner Flap Actuator Short To Ground
  • Output voltage (hardware values) < 1.92 - 2.21 V
  • Engine running
  • Actuator commanded off
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the Intake Manifold Runner Control Valve -N316-. Refer to Intake Manifold Runner Control Valve -N316-, CHECKING .
P2010 Intake Manifold Runner Control Circuit High Bank 1 Intake Manifold Runner Flap Actuator Short To Battery Plus
  • Power stage temperature > 160 - 200° C
  • Or
  • Output current (hardware values) driver stage internal value
  • Engine running
  • Actuator commanded on
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the Intake Manifold Runner Control Valve -N316-. Refer to Intake Manifold Runner Control Valve -N316-, CHECKING .
P2014 Intake Manifold Runner Position Sensor/Switch Circuit Bank 1 Intake Manifold Runner Flap Position Sensor Short To Ground / Open Circuit
  • Intake manifold runner flap position sensor voltage < 0.20 V
  • Engine start not active
  • 0.04 s
  • Continuous
  • 2 DCY
-- Check the Intake Manifold Runner Position Sensor -G336-. Refer to Intake Manifold Runner Position Sensor -G336-, CHECKING .
P2015 Intake Manifold Runner Position Sensor/Switch Circuit Range/Performance Bank 1 Intake Manifold Runner Flap Actuator Adaptation Value Monitoring
  • Diff. actual value vs. substitution value @ lower mechanical thresh hold > 0.70 V
  • Or
  • Diff. actual value vs. substitution value @ upper mechanical thresh hold > 0.70 V
  • Failed adaptations >= 1.00 [-]
  • Modeled air temperature < 0.75 [-]
  • Engine running
  • Engine speed > 640; < 1, 504 RPM
  • ECT @ cylinder head > -30° C
  • Intake manifold runner flap adaptation not finished
  • 0.04 s
  • Once per lifetime
  • 2 DCY
-- Check the Intake Manifold Runner Position Sensor -G336-. Refer to Intake Manifold Runner Position Sensor -G336-, CHECKING .
P2017 Intake Manifold Runner Position Sensor/Switch Circuit High Bank 1 Intake Manifold Runner Flap Position Sensor Short To Battery Voltage
  • Intake manifold runner flap position sensor voltage > 4.80 V
  • Engine start not active
  • 0.04 s
  • Continuous
  • 2 DCY
-- Check the Intake Manifold Runner Position Sensor -G336-. Refer to Intake Manifold Runner Position Sensor -G336-, CHECKING .
P2024 EVAP Fuel Vapor Temperature Sensor Circuit Smart Temperature Sensor Open Circuit
  • NVLD output voltage lower range >= 1.92 - 2.21 V
  • NVLD output voltage upper range <= 2.85 - 3.25 V
  • Case 1:
  • Ignition on
  • Case 2:
  • Ignition off (during ECM keep alive-time)
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Fuel Tank Leak Detection Control Module -J909- / Fuel Tank Pressure Sensor -G400-. Refer to Fuel Tank Leak Detection Control Module -J909- / Fuel Tank Pressure Sensor -G400-, CHECKING .
P2025 EVAP Fuel Vapor Temperature Sensor Performance Smart Temperature Sensor Functional Check*
  • Diff. time between ECU and smart module > 3.0 s
  • Ignition off
  • ECM keep alive time active
  • 3.0 s
  • Once / DCY
  • 2 DCY
-- Check the Fuel Tank Leak Detection Control Module -J909- / Fuel Tank Pressure Sensor -G400-. Refer to Fuel Tank Leak Detection Control Module -J909- / Fuel Tank Pressure Sensor -G400-, CHECKING .
  • Reset counter > 3.00 [-]
  • Engine running
  • Last ECM keep alive mode finished
  • 0.1 s
  • Once / DCY
  • 3 DCY
Smart Temperature Sensor Out Of Range High*
  • Smart module temperature > 119° C
  • Ignition off
  • NVLD (EVAP-System) diagnostic mode = active
  • Fuel level < 85.10%
  • 300 s
  • Continuous
  • 2 DCY
  • Engine Running
  • 30 s
  • Continuous
Smart Temperature Sensor Out Of Range Low*
  • Smart module temperature < -39° C
  • Engine off time >= 360.00 min
  • ECT @ cylinder head > -23° C
  • IAT cross check finished
  • ECT cross check finished
  • Fuel level < 85.10%
  • 1.0 s
  • Once / DCY
Smart Temperature Sensor Cross Check*
  • Difference between smart temperature and ECT @ cylinder head >= 25.5 K
  • And
  • Difference between smart temperature @ engine start and IAT @ manifold >= 25.5 K
  • Engine off time >= 360.00 min
  • IAT cross check finished
  • ECT cross check finished
  • Fuel level < 85.10%
Smart Temperature Sensor Signal Dynamic Check*
  • Gradient smart temperature > 20 K/10min
  • Ignition off
  • Fuel level < 85.10 %
  • NVLD (EVAP-System) diagnostic mode active
  • 300 s
  • Once / DCY
Smart Temperature Sensor Communication with Smart Temperature Sensor*
  • Response time > 1.0 s
  • And
  • Number of checks > 3.00 [-]
  • Or
  • Security bit incorrect
  • And
  • Number of checks > 3.00 [-]
  • Case 1:
  • Ignition on
  • Engine running
  • Case 2:
  • Ignition off (during ECM keep alive-time)
  • 5.0 s
  • Continuous
P2026 EVAP Fuel Vapor Temperature Sensor Circuit Low Voltage Smart Temperature Sensor Short To Ground
  • NVLD output voltage < 1.92 - 2.21 V
  • Case 1:
  • Ignition on
  • Case 2:
  • Ignition off (during ECM keep alive-time)
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Fuel Tank Leak Detection Control Module -J909- / Fuel Tank Pressure Sensor -G400-. Refer to Fuel Tank Leak Detection Control Module -J909- / Fuel Tank Pressure Sensor -G400-, CHECKING .
P2027 EVAP Fuel Vapor Temperature Sensor Circuit High Voltage Smart Temperature Sensor Short To Battery Voltage
  • NVLD output temperature > 160.0 - 200.0° C
  • Or
  • NVLD output current driver stage internal value
  • Case 1:
  • Ignition on
  • Case 2:
  • Ignition off (during ECM keep alive-time)
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Fuel Tank Leak Detection Control Module -J909- / Fuel Tank Pressure Sensor -G400-. Refer to Fuel Tank Leak Detection Control Module -J909- / Fuel Tank Pressure Sensor -G400-, CHECKING .
P2067 Fuel Level Sensor "B" Circuit Low COM: Fuel Level (FL) Sensor 2 communication with IPC
  • Instrument cluster module signal: short to groundfailure
  • Instrument cluster module signal: signal range checkfailure
 
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Fuel Level Sensor -G-. Refer to appropriate repair information.
P2068 Fuel Level Sensor "B" Circuit High COM: Fuel Level (FL) Sensor 2 communication with IPC
  • Instrument cluster module signal: short to battery / open circuitfailure
 
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Fuel Level Sensor -G-. Refer to appropriate repair information.
P2088 "A" Camshaft Position Actuator Control Circuit Low Bank 1 VVT Actuator Intake Short To Ground
  • Output voltage (hardware values) < 1.92 - 2.21 V
  • Actuator commanded off
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the Camshaft Adjustment Valve 1 -N205-. Refer to Camshaft Adjustment Valve 1 -N205-, CHECKING .
P2089 "A" Camshaft Position Actuator Control Circuit High Bank 1 VVT Actuator Intake Short To Battery Plus
  • Power stage temperature > 160 - 200° C
  • Or
  • Output current (hardware values) driver stage internal value
  • Actuator commanded on
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the Camshaft Adjustment Valve 1 -N205-. Refer to Camshaft Adjustment Valve 1 -N205-, CHECKING .
P2090 "B" Camshaft Position Actuator Control Circuit Low Bank 1 Variable Valve Timing (VVT) Exhaust Actuator short to ground
  • Output voltage< 1.92 - 2.21 V (hardware values)
  • Actuator commanded off
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the Exhaust Camshaft Adjustment Valve 1 -N318-. Refer to Exhaust Camshaft Adjustment Valve 1 -N318-, CHECKING
P2091 "B" Camshaft Position Actuator Control Circuit High Bank 1 Variable Valve Timing (VVT) Exhaust Actuator short to battery plus
  • Power stage temperature > 160 - 200° C
  • Or
  • Output currentdriver stage internal value (hardware values)
  • Actuator commanded on
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the Exhaust Camshaft Adjustment Valve 1 -N318-. Refer to Exhaust Camshaft Adjustment Valve 1 -N318-, CHECKING
P2096 Post Catalyst Fuel Trim System Too Lean Bank 1 Fuel System Out Of Range Low
  • Adaptation value < 0.05 [-]
  • 2nd lambda control n.a.
  • Catalyst purge not active
  • Injection mode change (DFI/MFI)not active
  • Engine speed >= 896 RPM
  • Integrated mass for fuel in oil < 255.00 [-]
  • Choice of:
  • O2S rear (binary) check not active
  • Or
  • O2S rear (binary) check finished
  • 0.0 s
  • Continuous
  • 2 DCY
-- Check exhaust system visually for leaks first and correct as necessary.-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter -GX7-, CHECKING .
P2097 Post Catalyst Fuel Trim System Too Rich Bank 1 Fuel System Out Of Range High
  • Adaptation value > -0.05 [-]
  • 2nd lambda control n.a.
  • Catalyst purge not active
  • Injection mode change (DFI/MFI)not active
  • Engine speed >= 896 RPM
  • Integrated mass for fuel in oil < 255.00 [-]
  • Choice of:
  • O2S rear (binary) check not active
  • Or
  • O2S rear (binary) check finished
  • 0.0 s
  • Continuous
  • 2 DCY
-- Check exhaust system visually for leaks first and correct as necessary.-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter -GX7-, CHECKING .
P2100 Throttle Actuator "A" Control Motor Circuit/Open Throttle Actuator Open Circuit
  • Electronic throttle valve driver load resistance > 200.0 kOhm
  • Difference between measured and filtered throttle position <= 0.073° TPS
  • Actuator commanded off
  • 0.1 s
  • Continuous
  • 2 DCY
-- Check the Throttle Valve Control Module -GX3-. Refer to Throttle Valve Control Module -GX3-, CHECKING .
P2101 Throttle Actuator "A" Control Motor Circuit Range/Performance Throttle Actuator Over Temperature
  • Electronic throttle valve driver temperature (hardware values) > 170.0 - 190.0° C
  • Actuator commanded on
  • 0.1 s
  • Continuous
  • 2 DCY
-- Check the Throttle Valve Control Module -GX3-. Refer to Throttle Valve Control Module -GX3-, CHECKING .
P2103 Throttle Actuator "A" Control Motor Circuit High Throttle Actuator Short Circuit
  • Electronic throttle valve driver current (hardware values) driver stage internal value
  • Actuator commanded on
  • 0.1 s
  • Continuous
  • 2 DCY
-- Check the Throttle Valve Control Module -GX3-. Refer to Throttle Valve Control Module -GX3-, CHECKING .
P2122 Throttle/Pedal Position Sensor/Switch "D" Circuit Low Accelerator Pedal Position Sensor 1 Out Of Range Low
  • Signal voltage sensor 1 < 0.40 V
 
  • 0.3 s
  • Continuous
  • 2 DCY
-- Check the Accelerator Pedal Module -GX2-. Refer to Accelerator Pedal Module -GX2-, CHECKING .
P2123 Throttle/Pedal Position Sensor/Switch "D" Circuit High Accelerator Pedal Position Sensor 1 Out Of Range High
  • Signal voltage sensor 1 > 4.82 V
 
  • 0.3 s
  • Continuous
  • 2 DCY
-- Check the Accelerator Pedal Module -GX2-. Refer to Accelerator Pedal Module -GX2-, CHECKING .
P2127 Throttle/Pedal Position Sensor/Switch "E" Circuit Low Accelerator Pedal Position Sensor 2 Out Of Range Low
  • Signal voltage sensor 2 < 0.20 V
 
  • 0.3 s
  • Continuous
  • 2 DCY
-- Check the Accelerator Pedal Module -GX2-. Refer to Accelerator Pedal Module -GX2-, CHECKING .
P2128 Throttle/Pedal Position Sensor/Switch "E" Circuit High Accelerator Pedal Position Sensor 2 Out Of Range High
  • Signal voltage sensor 2 > 2.80 V
 
  • 0.3 s
  • Continuous
  • 2 DCY
-- Check the Accelerator Pedal Module -GX2-. Refer to Accelerator Pedal Module -GX2-, CHECKING .
P2138 Throttle/Pedal Position Sensor/Switch "D"/"E" Voltage Correlation Accelerator Pedal Position Sensor 1 And 2 Rationality Check
  • Difference between signal voltage sensor 1 and sensor 2 > 0.10 - 0.12 V
 
  • 0.4 s
  • Continuous
  • 2 DCY
-- Check the Accelerator Pedal Module -GX2-. Refer to Accelerator Pedal Module -GX2-, CHECKING .
P2177 System Too Lean Off Idle Bank 1 Fuel System Direct Fuel Injection System Too Lean
  • Adaptive value >= 28.0 %
  • MAF > 60.0 mg/rev
  • ECT @ cylinder head > 20° C
  • IAT @ manifold > -48° C
  • AAT > -48° C
  • Lambda set point 0.95 - 1.05 [-]
  • Lambda control closed loop
  • Integrated MAF >= 600.0 - 10, 000.0 g
  • Fuel mass15.01 - 50.00 mg/rev
  • Engine speed1, 024 - 3, 744 rpm
  • Low dynamic conditions:
  • Diff. engine speed vs. averaged engine speed for engine speed dynamic detection< 60 - 130 rpm
  • Diff. air mass vs. averaged air mass for load dynamic detection< 16.00 - 30.01 mg/rev
  • Diff. between reference and actual fuel pressure, high side<= 2000.10 kPa
  • Integrated air mass> 5.0 - 25.0 g
  • And
  • Evap purge valve closed or canister load<= 1.20[-]
  • Evap purge flowat max. value
  • Or
  • Dependence on canister purge min:
  • Lower limit of lambda controller outputn.a.
  • Or
  • Upper limit of lambda controller outputn.a.
  • And
  • Evap purge flowat min. value
  • 5.0 s
  • Continuous
  • 2 DCY
-- Check the intake and vacuum hoses visually for leaks. Check the Positive Crankcase Ventilation visually. Also make sure the oil dipstick is properly secured.-- Listen to and visually inspect the exhaust system to insure there are no leaks.-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter -GX10-, CHECKING .-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter -GX7-, CHECKING .-- Check the Intake Manifold Sensor -GX9-. Refer to Intake Manifold Sensor -GX9-, CHECKING .-- Check the EVAP Canister Purge Regulator Valve 1 -N80-. Refer to EVAP Canister Purge Regulator Valve 1 -N80-, CHECKING .-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
P2178 System Too Rich Off Idle Bank 1 Fuel System Direct Fuel Injection System Too Rich
  • Adaptive value <= -30.0 %
  • Air mass> 60.00 mg/rev
  • ECT @ cylinder head> 20° C
  • IAT @ manifold> -48° C
  • AAT> -48° C
  • Lambda setpoint0.97 - 1.05[-]
  • Lambda controlclosed loop
  • Integrated air mass>= 600.0 - 10, 000.0g
  • Fuel mass15.01 - 50.00mg/rev
  • Engine speed1, 024 - 3, 744 rpm
  • Low dynamic conditions:
  • Diff. engine speed vs. averaged engine speed for engine speed dynamic detection< 60 - 130 rpm
  • Diff. air mass vs. averaged air mass for load dynamic detection< 16.00 - 30.01 mg/rev
  • Diff. between reference and actual fuel pressure, high side<= 2, 000.10 kPa
  • Integrated air mass> 5.0 - 25.0 g
  • And
  • Evap purge valve closed
  • Or
  • Canister load<= 1.20[-]
  • Evap purge flowat max. value
  • Or
  • Dependence on canister purge min:
  • Lower limit of lambda controller outputn.a.
  • Or
  • Upper limit of lambda controller outputn.a.
  • And
  • Evap purge flowat min. value
  • 5.0 s
  • Continuous
  • 2 DCY
-- Check the Evaporative Emission (EVAP) System visually for contamination.-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter -GX10-, CHECKING .-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter -GX7-, CHECKING .-- Check the Intake Manifold Sensor -GX9-. Refer to Intake Manifold Sensor -GX9-, CHECKING .-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
P2181 Cooling System Performance Engine Cooling System Rationality Check
  • Modeled ECT @ cylinder head > 66 - 70° C
  • Choice of:
  • ECT @ cylinder head < 65 - 69° C
  • Or
  • ECT @ radiator outlet < n.a.° C
  • ECT @ cylinder head @ first start >= -10° C
  • ECT @ cylinder head @ first start <= 50 - 55° C
  • AAT > -10° C
  • Ratio fuel cut off <= 10.16 %
  • Ratio accumulated time engine load condition vs. time since engine start <= 39.84 %
  • Determination engine load condition:
  • Engine load (lower threshold)<= 2.50%
  • engine load (upper threshold)>= 100.00%
  • Ratio accumulated time high speed condition<= 14.84 %
  • Determination high speed condition:
  • Vehicle speed> 75mph
  • Ratio accumulated time start-stop active<= 16.02 %
  • Setpoint of RVC in measurement window< 99.61 %
  • Case 1:
  • Engine speed< 8, 160rpm
  • Case 2:
  • Engine speed>= 8, 160 rpm
  • Diff. ECT@ cylinder head during measurement< 256° C
  • For time>= 0.0 s
  • 1.0 s
  • Once / DCY
  • 2 DCY
-- Check cooling system visually for leaks or damaged components.-- Check the Engine Temperature Control Actuator -N493-. Refer to Engine Temperature Control Actuator -N493-, CHECKING .-- Check the Engine Coolant Temperature Sensor -G62-. Refer to Engine Coolant Temperature Sensor -G62-, CHECKING .
Electrical Thermostat Rationality Check
  • ECT @ cylinder head < 60° C
  • For time >= 0.0 s
  • Engine running
  • Or
  • Engine stopped
  • And
  • ECT @ cylinder head once after start > 65° C
  • Or
  • ECT @ radiator outlet once after engine startnot calibrated[°C]
  • And
  • AAT sensor signal valid
  • AAT > -10° C
  • Relative actual MAF > 5.00 %
  • ECT @ cylinder head @ first start lower limit >= -40° C
  • ECT @ cylinder head @ first start upper limit<= 215[°C]
  • Vehicle speed >= 0 mph
  • Modeled ECT @ cylinder head > 60° C
  • Start-stop cycles <= 255.00 [-]
  • For time >= 15.0 s
P2183 Engine Coolant Temperature Sensor 2 Circuit Range/Performance Engine Coolant Temperature Sensor @ Radiator Outlet Cross Check
  • High side: reference measuring
  • Diff. ECT @ radiator outlet @ cold start vs. IAT @ manifold @ cold start> 25.0 K
  • Diff. ECT @ radiator outlet @ cold start vs. ECT @ cylinder head @cold startn.a. K
  • Diff. ECT @ radiator outlet @ cold start vs. AAT @ cold start> 25.0 K
  • Min. amount of faulty reference measurements to detect defective sensor2.00[-]
  • Or
  • Low side: reference measuring
  • Diff. IAT @ manifold @ cold start vs. ECT @ radiator outlet @ cold start> 25.0 K
  • Diff. ECT @ cylinder head @ cold start vs. ECT @ radiator outlet @cold startn.a. K
  • Diff. AAT @ cold start vs. ECT @ radiator outlet @ cold start> 25.0 K
  • Min. amount of faulty reference measurements to detect defective sensor2.00[-]
  • Engine off time>= 360.00 min
  • Engine off timeplausible
  • Time after engine start<= 1, 400.0 s
  • Depending on temperature slope
  • Diff. actual vs previous IAT< 256.0 K
  • Diff. actual vs previous ECT@ cylinder headn.a.K
  • Diff. actual vs previous ECT@ radiator outlet< 256.0K
  • Diff. actual vs previous AAT< 256.0 K
  • For time>= 1.0 s
  • Depending on mean value condition
  • Mean value of all temperature sensors @ cold start>= -256° C
  • Number of valid sensors>= 2.00[-]
  • Depending on block heater / solar radiation detection
  • Time after engine start>= 0.5 s
  • Vehicle speed>= 22 mph
  • For time>= 20.0 s
  • Diff. actual IAT @ manifold vs. min. IAT @ manifold< 5.0 K
  • Diff. actual ECT @ cylinder head vs. min. ECT @ cylinder headn.a.K
  • Diff. actual AAT vs. min. AAT< 4.0 K
  • Diff. actual ECT @ radiator outlet vs. min. ECT @ radiator outlet< 1.1 K
  • 0.1 s
  • Once / DCY
  • 2 DCY
-- Check the Engine Coolant Temperature Sensor On Radiator Outlet -G83-. Refer to Engine Coolant Temperature Sensor On Radiator Outlet -G83-, CHECKING .
P2184 Engine Coolant Temperature Sensor 2 Circuit Low Engine Coolant Temperature Sensor @ Radiator Outlet Short To Ground
  • Sensor voltage < 0.30 V
 
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Engine Coolant Temperature Sensor On Radiator Outlet -G83-. Refer to Engine Coolant Temperature Sensor On Radiator Outlet -G83-, CHECKING .
P2185 Engine Coolant Temperature Sensor 2 Circuit High Engine Coolant Temperature Sensor @ Radiator Outlet Short To Battery / Open Circuit
  • Sensor voltage > 4.90 V
  • IAT @ throttle >= -33° C
  • Time after engine start > 60 s
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Engine Coolant Temperature Sensor On Radiator Outlet -G83-. Refer to Engine Coolant Temperature Sensor On Radiator Outlet -G83-, CHECKING .
P2187 System Too Lean at Idle Bank 1 Fuel System Direct Fuel Injection System Too Lean
  • Case 1:
  • Adaptive value >= 3.01 mg/rev
  • Case 2:
  • Adaptive value n.a.
  • Air mass> 60.00mg/rev
  • ECT @ cylinder head> 20° C
  • IAT @ manifold> -48° C
  • AAT> -48° C
  • Lambda setpoint0.97 - 1.05[-]
  • Lambda controlclosed loop
  • Integrated air mass>= 600.0 - 10, 000.0 g
  • Vehicle speed< 4mph
  • Low dynamic conditions:
  • Diff. engine speed vs. averaged engine speed for engine speed dynamic detection< 60 - 130 rpm
  • Diff. air mass vs. averaged air mass for load dynamic detection< 16.00 - 30.01mg/rev
  • Diff. between reference and actual fuel pressure, high side<= 2000.10 kPa
  • Integrated air mass> 5.0 - 25.0 g
  • And
  • Fuel mass lower range> 4.01 mg/rev
  • Fuel mass upper range< 17.00 - 19.01mg/rev
  • Engine speed704 - 927[rpm]
  • Or
  • Engine n.a.
  • And
  • Evap purge valve closed
  • Or
  • Canister load<= 1.20[-]
  • Evap purge flowat max. value
  • Or
  • Depending on canister purge min:
  • Lower limit of lambda controller outputn.a.
  • Or
  • Upper limit of lambda controller outputn.a.
  • And
  • Evap purge flowat min. value
  • 5.0 s
  • Continuous
  • 2 DCY
-- Check the intake and vacuum hoses visually for leaks. Check the Positive Crankcase Ventilation visually. Also make sure the oil dipstick is properly secured.-- Listen to and visually inspect the exhaust system to insure there are no leaks.-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter -GX10-, CHECKING .-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter -GX7-, CHECKING .-- Check the Intake Manifold Sensor -GX9-. Refer to Intake Manifold Sensor -GX9-, CHECKING .-- Check the EVAP Canister Purge Regulator Valve 1 -N80-. Refer to EVAP Canister Purge Regulator Valve 1 -N80-, CHECKING .-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
P2188 System Too Rich at Idle Bank 1 Fuel System Direct Fuel Injection System Too Rich
  • Case 1:
  • Adaptive value <= -3.01 mg/rev
  • Case 2:
  • Adaptive value <= n.a. kg/h
  • Air mass> 60.00mg/rev
  • ECT @ cylinder head> 20° C
  • IAT @ manifold> -48° C
  • AAT> -48° C
  • Lambda setpoint0.97 - 1.05[-]
  • Lambda controlclosed loop
  • Oil dilutionnot detected
  • Integrated air mass>= 600.0 - 10, 000.0 g
  • Vehicle speed< 4 mph
  • Low dynamic conditions:
  • Diff. engine speed vs. averaged engine speed for engine speed dynamic detection< 60 - 130 rpm
  • Diff. air mass vs. averaged air mass for load dynamic detection< 16.00 - 30.01 mg/rev
  • Diff. between reference and actual fuel pressure, high side<= 2000.10 kPa
  • Integrated air mass> 5.0 - 25.0 g
  • And
  • Fuel mass lower range> 4.01 mg/rev
  • Fuel mass upper range< 17.00 - 19.01 mg/rev
  • Engine speed704 - 927 rpm
  • Or
  • Engine n.a.
  • And
  • Evap purge valve closed
  • Or
  • Canister load<= 1.20[-]
  • Evap purge flowat max. value
  • Or
  • Depending on canister purge min:
  • Lower limit of lambda controller outputn.a.
  • Or
  • Upper limit of lambda controller outputn.a.
  • And
  • Evap purge flowat min. value
  • 5.0 s
  • Continuous
  • 2 DCY
-- Check the Evaporative Emission (EVAP) System visually for contamination.-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter -GX10-, CHECKING .-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter -GX7-, CHECKING .-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
P2195  O2 Sensor Signal Biased/Stuck Lean Bank 1 Sensor 1 Oxygen Sensors Front Rationality Check
  • Plausibility signal check O2S front and O2S rear:
  • Lambda value > 1.15 [-]
  • And
  • O2S signal rear >= 0.91 [V]
  • O2S front ready
  • O2S rear ready
  • ECT @ cylinder head >= -48° C
  • MAF > 0.0; < 2, 047.0 kg/h
  • Catalyst purge not active
  • Integrated MAF after end of catalyst purge 10.0 g
  • Engine speed > 0 RPM
  • Modeled EGT @ O2S front > -273; < 850° C
  • Integrated MAF > 40.0 g
  • Dynamic lambda controller output < 3.0 %
  • Dynamic MAF < 0.05 g/rev
  • Dynamic engine speed < 200 RPM
  • And
  • Second control loop active:
  • MAF 0.06 - 0.75 g/rev
  • Engine speed 576 - 4512 RPM
  • 67.5 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter -GX10-, CHECKING .
P2196  O2 Sensor Signal Biased/Stuck Rich Bank 1 Sensor 1 Oxygen Sensors Front Rationality Check
  • Plausibility signal check O2S front and O2S rear:
  • Lambda value < 0.85 [-]
  • And
  • O2S signal rear >= 0.17 V
  • O2S frontready
  • O2S rearready
  • ECT @ cylinder head>= -48° C
  • MAF> 0.00; < 2047.97 kg/h
  • Catalyst purgenot active
  • Integrated air mass after end of catalyst purge10.0 g
  • Engine speed> 0rpm
  • Modeled EGT @ O2S front> -273; < 850° C
  • Injection mode change (DFI/MFI)not active
  • Integrated air mass> 40.0 g
  • Dynamic lambda controller output< 3.00 %
  • Dynamic air mass< 0.05 g/rev
  • Dynamic engine speed< 200 rpm
  • And
  • Second control loop active:
  • Air mass 0.06 - 0.75 g/rev
  • Engine speed576 - 4, 512 rpm
  • 67.5 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter -GX10-, CHECKING .
P219C Cylinder 1 Air-Fuel Ratio Imbalance Air Fuel Imbalance Monitoring Out Of Range High
  • Cylinder 1:
  • Weighted adaptive value > 10.0 %
  • Fuel pressure setpointnot calibrated kPa
  • Modeled catalyst temperature @ start <= 850° C
  • Lambda set value 0.97 - 1.03 [-]
  • Catalyst heating not active
  • Engine roughness signal valid
  • Cylinder shut off not active
  • AAT >= -48° C
  • Barometric pressure >= 73.0 kPa
  • min. injection time not reached
  • And
  • Choice of:
  • Catalyst diagnosis n.a.
  • Or
  • Catalyst diagnosis n.a.
  • Depending on catalyst diagnosis:
  • Canister purge (conditions) n.a.
  • Or
  • Evap purge valve n.a.
  • Or
  • Evap purge n.a.
  • And
  • O2S dynamic diagnosis n.a.
  • O2S delay diagnosis n.a.
  • Lambda control closed loop
  • Catalyst purge not active
  • Canister load <= 2.00 [-]
  • Engine no full load
  • Segment adaptation finished
  • Catalyst damaging misfire not detected
  • Emission threshold misfire not detected
  • No gear switch for segments >= 90.00 [-]
  • Segments after start > 0.00 [-]
  • Time after engine start > 0.0 s
  • Rough road not detected
  • Min. fuel mass>= 0.00 mg/rev
  • Intake manifold runner flap position changenot active
  • Injection mode change (DFI/MFI)not equipped
  • Valve lift position changenot active
  • Depending on gear:
  • 1st gear not active
  • 2nd gear not active
  • 3rd gear not active
  • 4th gear active
  • 5th gear active
  • 6th gear active
  • 7th gear active
  • 8th gear not active
  • And
  • Integrated MAF >= 1.0 - 12.0 kg
  • Diff. engine speed vs. dynamic engine speed < 200 RPM
  • Diff. MAF vs. dynamic MAF < 29.99 mg/rev
  • ECT @ cylinder head 60 - 143° C
  • Adaptation cycles <= 255 [-]
  • Engine speed 1, 312 - 3, 008 RPM
  • And
  • Mass fuel flow lower range >= 11.00 mg/rev
  • Mass fuel flow upper range <= 32.00 mg/rev
  • 90 s
  • Once / DCY
  • 2 DCY
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
Air Fuel Imbalance Monitoring Out Of Range Low
  • Cylinder 1:
  • Weighted adaptive value < -15.0 %
P219D Cylinder 2 Air-Fuel Ratio Imbalance Air Fuel Imbalance Monitoring Out Of Range High
  • Cylinder 1:
  • Weighted adaptive value > 10.0 %
  • Fuel pressure setpointnot calibrated kPa
  • Modeled catalyst temperature @ start <= 850° C
  • Lambda set value 0.97 - 1.03 [-]
  • Catalyst heating not active
  • Engine roughness signal valid
  • Cylinder shut off not active
  • AAT >= -48° C
  • Barometric pressure >= 73.0 kPa
  • Min. injection time not reached
  • And
  • Choice of:
  • Catalyst diagnosis n.a.
  • Or
  • Catalyst diagnosis n.a.
  • Depending on catalyst diagnosis:
  • Canister purge (conditions) n.a.
  • Or
  • Evap purge valve n.a.
  • Or
  • Evap purge n.a.
  • And
  • O2S dynamic diagnosis n.a.
  • O2S delay diagnosis n.a.
  • Lambda control closed loop
  • Catalyst purge not active
  • Canister load <= 2.00 [-]
  • Engine no full load
  • Segment adaptation finished
  • Catalyst damaging misfire not detected
  • Emission threshold misfire not detected
  • No gear switch for segments >= 90.00 [-]
  • Segments after start > 0.00 [-]
  • Time after engine start > 0.0 [s]
  • Rough road not detected
  • Min. fuel mass>= 0.00 mg/rev
  • Intake manifold runner flap position changenot active
  • Injection mode change (DFI/MFI)not equipped
  • Valve lift position changenot active
  • Depending on gear:
  • 1st gear not active
  • 2nd gear not active
  • 3rd gear not active
  • 4th gear active
  • 5th gear active
  • 6th gear active
  • 7th gear active
  • 8th gear not active
  • And
  • Integrated MAF >= 1.0 - 12.0 kg
  • Diff. engine speed vs. dynamic engine speed < 200 RPM
  • Diff. MAF vs. dynamic MAF < 29.99 mg/rev
  • ECT @ cylinder head 60 - 143° C
  • Adaptation cycles <= 255 [-]
  • Engine speed 1, 312 - 3, 008 RPM
  • And
  • Mass fuel flow lower range >= 11.00 mg/rev
  • Mass fuel flow upper range <= 32.00 mg/rev
  • 90 s
  • Once / DCY
  • 2 DCY
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
Air Fuel Imbalance Monitoring Out Of Range Low
  • Cylinder 2:
  • Weighted adaptive value < -15.0 %
P219E Cylinder 3 Air-Fuel Ratio Imbalance Air Fuel Imbalance Monitoring Out Of Range High
  • Cylinder 1:
  • Weighted adaptive value > 10.0 %
  • Fuel pressure setpointnot calibrated[kPa]
  • Modeled catalyst temperature @ start <= 850° C
  • Lambda set value 0.97 - 1.03 [-]
  • Catalyst heating not active
  • Engine roughness signal valid
  • Cylinder shut off not active
  • AAT >= -48° C
  • Barometric pressure >= 73.0 kPa
  • Min. injection time not reached
  • And
  • Choice of:
  • Catalyst diagnosis n.a.
  • Or
  • Catalyst diagnosis n.a.
  • Depending on catalyst diagnosis:
  • Canister purge (conditions) n.a.
  • Or
  • Evap purge valve n.a.
  • Or
  • Evap purge n.a.
  • And
  • O2S dynamic diagnosis n.a.
  • O2S delay diagnosis n.a.
  • Lambda control closed loop
  • Catalyst purge not active
  • Canister load <= 2.00 [-]
  • Engine no full load
  • Segment adaptation finished
  • Catalyst damaging misfire not detected
  • Emission threshold misfire not detected
  • No gear switch for segments >= 90.00 [-]
  • Segments after start > 0.00 [-]
  • Time after engine start > 0.0 [s]
  • Rough road not detected
  • Min. fuel mass>= 0.00[mg/rev]
  • Intake manifold runner flap position changenot active
  • Injection mode change (DFI/MFI)not equipped
  • Valve lift position changenot active
  • Depending on gear:
  • 1st gear not active
  • 2nd gear not active
  • 3rd gear not active
  • 4th gear active
  • 5th gear active
  • 6th gear active
  • 7th gear active
  • 8th gear not active
  • And
  • Integrated MAF >= 1.0 - 12.0 kg
  • Diff. engine speed vs. dynamic engine speed < 200 RPM
  • Diff. MAF vs. dynamic MAF < 29.99 mg/rev
  • ECT @ cylinder head 60 - 143° C
  • Adaptation cycles <= 255 [-]
  • Engine speed 1, 312 - 3, 008 RPM
  • And
  • Mass fuel flow lower range >= 11.00 mg/rev
  • Mass fuel flow upper range <= 32.00 mg/rev
  • 90 s
  • Once / DCY
  • 2 DCY
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
Air Fuel Imbalance Monitoring Out Of Range Low
  • Cylinder 3:
  • Weighted adaptive value < -15.0 %
P219F Cylinder 4 Air-Fuel Ratio Imbalance Air Fuel Imbalance Monitoring Out Of Range High
  • Cylinder 1:
  • Weighted adaptive value > 10.0 %
  • Fuel pressure setpointnot calibrated[kPa]
  • Modeled catalyst temperature @ start <= 850° C
  • Lambda set value 0.97 - 1.03 [-]
  • Catalyst heating not active
  • Engine roughness signal valid
  • Cylinder shut off not active
  • AAT >= -48° C
  • Barometric pressure >= 73.0 kPa
  • Min. injection time not reached
  • And
  • Choice of:
  • Catalyst diagnosis n.a.
  • Or
  • Catalyst diagnosis n.a.
  • Depending on catalyst diagnosis:
  • Canister purge (conditions) n.a.
  • Or
  • Evap purge valve n.a.
  • Or
  • Evap purge n.a.
  • And
  • O2S dynamic diagnosis n.a.
  • O2S delay diagnosis n.a.
  • Lambda control closed loop
  • Catalyst purge not active
  • Canister load <= 2.00 [-]
  • Engine no full load
  • Segment adaptation finished
  • Catalyst damaging misfire not detected
  • Emission threshold misfire not detected
  • No gear switch for segments >= 90.00 [-]
  • Segments after start > 0.00 [-]
  • Time after engine start > 0.0 [s]
  • Rough road not detected
  • Min. fuel mass>= 0.00[mg/rev]
  • Intake manifold runner flap position changenot active
  • Injection mode change (DFI/MFI)not equipped
  • Valve lift position changenot active
  • Depending on gear:
  • 1st gear not active
  • 2nd gear not active
  • 3rd gear not active
  • 4th gear active
  • 5th gear active
  • 6th gear active
  • 7th gear active
  • 8th gear not active
  • And
  • Integrated MAF >= 1.0 - 12.0 kg
  • Diff. engine speed vs. dynamic engine speed < 200 RPM
  • Diff. MAF vs. dynamic MAF < 29.99 mg/rev
  • ECT @ cylinder head 60 - 143° C
  • Adaptation cycles <= 255 [-]
  • Engine speed 1, 312 - 3, 008 RPM
  • And
  • Mass fuel flow lower range >= 11.00 mg/rev
  • Mass fuel flow upper range <= 32.00 mg/rev
  • 90 s
  • Once / DCY
  • 2 DCY
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
Air Fuel Imbalance Monitoring Out Of Range Low
  • Cylinder 4:
  • Weighted adaptive value < -15.0 %
P2237 O2 Sensor Positive Current Control Circuit/Open Bank 1 Sensor 1 Oxygen Sensors Front Open Circuit Pump Voltage (VIP)
  • Diff. pump voltage (VIP) vs. virtual ground voltage (VG) <= 1.20 V
  • Diff. nernst voltage (VN) vs. virtual ground voltage (VG) <= 1.20 V
  • And
  • Choice of:
  • Nernst voltage (VN) > 4.40 V
  • Or
  • Diff. pump voltage (VIP) vs. virtual ground voltage (VG) > 2.35 V
  • Diff. pump voltage (VIP) vs. virtual ground voltage (VG) < -2.35 V
  • Or
  • Diff. nernst voltage (VN) vs. virtual ground voltage (VG) > 1.60 V
  • Diff. nernst voltage (VN) vs. virtual ground voltage (VG) < -0.10 V
  • Or
  • Pump current driver stage internal value
  • Or
  • Measurement WRAF sensor label resistor > n.a. Ohm
  • O2S front (linear) ready
  • O2S ceramic temperature> 785° C
  • For time>= 10.0s
  • 2.3 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter -GX10-, CHECKING .
P2243 O2 Sensor Reference Voltage Circuit/Open Bank 1 Sensor 1 Oxygen Sensors Front Open Circuit Nernst Voltage (VN)
  • Diff. pump voltage (VIP) vs. virtual ground voltage (VG) <= 1.20 V
  • Diff. nernst voltage (VN) vs. virtual ground voltage (VG) <= 1.20 V
  • And
  • Choice of:
  • Nernst voltage (VN) > 4.40 V
  • Or
  • Diff. pump voltage (VIP) vs. virtual ground voltage (VG) > 2.35 V
  • Diff. pump voltage (VIP) vs. virtual ground voltage (VG) < -2.35 V
  • Or
  • Diff. nernst voltage (VN) vs. virtual ground voltage (VG) > 1.60 V
  • Diff. nernst voltage (VN) vs. virtual ground voltage (VG) < -0.10 V
  • Or
  • Pump currentdriver stage internal value
  • Or
  • Measurement WRAF sensor label resistor > n.a. Ohm
  • O2S front (linear) ready
  • O2S ceramic temperature> 785° C
  • For time>= 10.0s
  • 2.3 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter -GX10-, CHECKING .
P2251 O2 Sensor Negative Current Control Circuit/Open Bank 1 Sensor 1 Oxygen Sensors Front Open Circuit Virtual Ground (VG)
  • Nernst voltage (VN) > 4.40 V
  • Or
  • Diff. pump voltage (VIP) vs. virtual ground voltage (VG) > 2.35 V
  • Diff. pump voltage (VIP) vs. virtual ground voltage (VG) < -2.35 V
  • Or
  • Diff. nernst voltage (VN) vs. virtual ground voltage (VG) > 1.60 V
  • Diff. nernst voltage (VN) vs. virtual ground voltage (VG) < -0.10 V
  • Or
  • Pump current driver stage internal value
  • Or
  • Measurement O2S front label resistor > n.a. Ohm
  • And
  • Choice of:
  • Diff. pump voltage (VIP) vs. virtual ground voltage (VG) <= 1.20 V
  • Diff. nernst voltage (VN) vs. virtual ground voltage (VG) <= 1.20 V
  • Or
  • Diff. pump voltage (VIP) vs. virtual ground voltage (VG)> 1.20V
  • Diff. nernst voltage (VN) vs. virtual ground voltage (VG)> 1.20V
  • O2S front (linear) ready
  • O2S ceramic temperature> 785° C
  • For time>= 10.0 s
  • 2.3 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter -GX10-, CHECKING .
P2257 AIR System Control "A" Circuit Low Secondary Air Injection Pump Relay Short To Ground
  • Output voltage (hardware values) 1.92 - 2.21 V
  • Engine running
  • Actuator commanded off
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the Secondary Air Injection Pump Motor -V101- / Secondary Air Injection Pump Relay -J299-. Refer to Secondary Air Injection Pump Motor -V101- / Secondary Air Injection Pump Relay -J299-, CHECKING .
P2258 AIR System Control "A" Circuit High Secondary Air Injection Pump Relay Short To Battery Plus
  • Actuator temperature > 160 - 200° C
  • Or
  • Output current (hardware values) driver stage internal value
  • Engine running
  • Actuator commanded on
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the Secondary Air Injection Pump Motor -V101- / Secondary Air Injection Pump Relay -J299-. Refer to Secondary Air Injection Pump Motor -V101- / Secondary Air Injection Pump Relay -J299-, CHECKING .
P2270  O2 Sensor Signal Biased/Stuck Lean Bank 1 Sensor 2 Oxygen Sensors Rear Signal Range Check
  • Max. O2S rear voltage < 0.87 V
  • Intrusive lambda ramp lean< 0.85[-]
  • General conditions:
  • Catalyst monitor lambda modulation requestactive
  • Vehicle speed>= 19 mph
  • Barometric pressure>= 0.00 kPa
  • Catalyst overheating protection not active
  • Turbine overheating protection not active
  • O2S rearready
  • O2S frontready
  • ECT @ cylinder head> 60° C
  • IAT @ manifold> -48° C
  • Modeled catalyst temperature @ start of diagnosis> 510° C
  • Modeled catalyst temperature @ during diagnosis470 - 830° C
  • Diff. between dynamic and stationary catalyst temperature-150 - 150° C
  • Integrated air mass, catalyst temp. conditions fulfilled>= 0.0 g
  • Modeled EGT @ O2S rear<= 900° C
  • MAF per cylinder22.50 - 150.00 kg/h
  • Air mass, lower range>= 0.00 mg/rev
  • Air mass, upper range<= 650.00 - 1389.00 mg/rev
  • And
  • Engine loadn.a.%
  • Air mass setpointn.a. mg/rev
  • Accelerator pedal valuen.a. %
  • For timen.a. s
  • And
  • Low dynamic conditions
  • Dynamic engine speed< 50 rpm
  • Dynamic air mass< 50.00 mg/rev
  • Dynamic lambda controller output< 20.00 %
  • And
  • Integrated air mass after dynamic conditions are fulfilled> 20.0 g
  • Time after a catalyst purge phase>= 1.0 s
  • O2S rear voltage @ diagnosis start>= 0.55 V
  • Integrated air mass>= 0.0 g
  • Integrated heat energy>= 550.00 - 700.00 kJ
  • Engine speed1, 088 - 3, 008 rpm
  • Deviation of lambda controller output< 50.00 %
  • Proportional part of secondary fuel control loopnot calibrated %
  • Coasting functionnot active
  • O2S heater rearactive
  • Lambda adaptationnot active
  • Valve liftnot active
  • And
  • Depending on Lambda control:
  • Sum of integral and proportional part of secondary fuel control loop before diagnosis< 0.10 [-]
  • Or
  • Sum of integral and proportional part of secondary fuel control loop during diagnosis< 0.25[-]
  • Depending on canister purge:
  • Canister loadn.a.[-]
  • Evap purge flown.a.
  • Or
  • Canister load calculationn.a.
  • Evap purge flown.a.
  • Or
  • Evap purge valven.a.
  • Or
  • Evap purge valven.a.
  • Or
  • Evap purgen.a.
  • Or
  • Depending on canister purge closing:
  • Canister purge (conditions)n.a.
  • Canister purge valve (closing time)n.a.[s]
  • And
  • Choice of: evap purge valven.a.
  • Or
  • Evap purge valven.a.
  • And
  • Modeled air mass integral> 50.0 g
  • Integrated air mass per cylinder>= 1.40 - 1.80 kg
  • 0 (FTP75: 50) s
  • Once / DCY
  • 2 DCY
-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter -GX7-, CHECKING .
P2271  O2 Sensor Signal Biased/Stuck Rich Bank 1 Sensor 2 Oxygen Sensors Rear Signal Range Check
  • O2S rear voltage> 0.25V
  • Intrusive lambda ramp lean> 1.12[-]
  • General conditions:
  • Catalyst monitor lambda modulation requestactive
  • Intrusive lambda ramp requestactive
  • Vehicle speed>= 19 mph
  • Barometric pressure>= 0.00 kPa
  • Catalyst overheating protectionnot active
  • Turbine overheating protectionnot active
  • O2S rearready
  • O2S frontready
  • ECT @ cylinder head> 60° C
  • IAT @ manifold> -48° C
  • Modeled catalyst temperature @ start of diagnosis> 510° C
  • Modeled catalyst temperature @ during diagnosis470 - 830° C
  • Diff. between dynamic and stationary catalyst temperature-150 - 150° C
  • Integrated air mass, catalyst temp. conditions fulfilled>= 0.0 g
  • Modeled EGT @ O2S rear<= 900° C
  • MAF per cylinder22.50 - 150.00 kg/h
  • Air mass, lower range>= 0.00 mg/rev
  • Air mass, upper range<= 650.00 - 1, 389.00 mg/rev
  • And
  • Engine loadn.a.%
  • Air mass setpointn.a. g/rev
  • Accelerator pedal valuen.a. %
  • For time n.a. s
  • And
  • Low dynamic conditions
  • Dynamic engine speed< 50 rpm
  • Dynamic air mass< 50.00mg/rev
  • Dynamic lambda controller output< 20.00 %
  • And
  • Integrated air mass after dynamic conditions are fulfilled> 20.0 g
  • Time after a catalyst purge phase>= 1.0 s
  • O2S rear voltage>= 0.55 V
  • Integrated air mass>= 0.0 g
  • Integrated heat energy>= 550.00 - 700.00 kJ
  • Engine speed1, 088 - 3, 008 rpm
  • Deviation of lambda controller output< 50.00 %
  • Proportional part of secondary fuel control loop not calibrated %
  • Coasting functionnot active
  • O2S heater rearactive
  • Lambda adaptationnot active
  • Valve liftnot active
  • And
  • Depending on Lambda control:
  • Sum of integral and proportional part of secondary fuel control loop before diagnosis< | 0.10 |[-]
  • Or
  • Sum of integral and proportional part of secondary fuel control loop during diagnosis< | 0.25 |[-]
  • Depending on canister purge:
  • Canister loadn.a.[-]
  • Evap purge flown.a.
  • Or
  • Canister load calculationn.a.
  • Evap purge flown.a.
  • Or
  • Evap purge valven.a.
  • Or
  • Evap purge valven.a.
  • Or
  • Evap purgen.a.
  • Or
  • Depending on canister purge closing:
  • Canister purge (conditions)n.a.
  • Canister purge valve (closing time)n.a.[s]
  • And
  • Choice of:
  • Evap purge valven.a.
  • Or
  • Evap purge valven.a.
  • And
  • Modeled air mass integral> 50.0 g
  • Integrated air mass per cylinder>= 1.40 - 1.80 kg
  • 0 (FTP75: 50) s
  • Once / DCY
  • 2 DCY
-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter -GX7-, CHECKING .
P2279 MAP/MAF - Throttle Position Correlation Intake Air System Rationality Check
  • Filtered lambda controller included correction and adaptation -30.0 - 30.0 %
  • Lambda control active
  • And
  • Deviation throttle area controller > 60.0 %
  • Throttle position > 0.0° TPS
  • Throttle position < 100.003° TPS
  • Engine speed > 576; < 3, 008 RPM
  • Modeled pressure quotient > 0.27; < 0.57 [-]
  • Engine running
  • Throttle actuator commanded on
  • Time after engine start > 5.0 s
  • Throttle position sensor failure not detected
  • Fuel cut off not active
  • Fast throttle adaptation finished
  • Gradient intake manifold pressure -199.90 - 199.90 kPa/s
  • Engine speed limitation not active
  • Barometric pressure plausibility diagnosis finished
  • Intake manifold modeled adaption active
  • And
  • Choice of:
  • MAF sensor active
  • Or
  • Manifold pressure sensor active
  • And
  • Choice of:
  • Pressure upstream throttle < 135.0 kPa
  • Or
  • Pressure upstream throttle not active
  • And
  • Choice of:
  • Barometric pressure > 73.00; < 107.50 kPa
  • Or
  • Barometric pressure sensor not active
  • 5.0 s
  • Continuous
  • 2 DCY
-- Check visually for air leaks between intake and throttle body, oil fill cap not tight or oil dipstick not seated in tube.-- Also visually inspect any engine gaskets that can cause additional air to enter the crankcase can set this fault as the PCV system is not metered. If a vacuum leak or crankcase gasket sealing is at cause, the idle may be rough or unstable.-- Check the Intake Manifold Sensor -GX9-. Refer to Intake Manifold Sensor -GX9-, CHECKING
  • Filtered lambda controller correction > 35.0 %
  • Filtered lambda controller correction -50.0 - 50.0 %
  • Lambda control active
  • Throttle position > 4.50° TPS
  • Engine speed > 1, 216; < 6, 000 RPM
  • Modeled pressure quotient > 0.63; < 0.90 [-]
  • Engine running
  • Throttle actuator commanded on
  • Time after engine start > 5.0 s
  • Throttle position sensor failure not detected
  • Fuel cut off not active
  • Fast throttle adaptation finished
  • Gradient intake manifold pressure -199.90 - 199.90 kPa/s
  • Barometric pressure plausibility diagnosis finished
  • And
  • Choice of:
  • MAF sensor active
  • Or
  • Manifold pressure sensor active
  • And
  • Choice of:
  • Pressure upstream throttle < 135.0 kPa
  • Or
  • Pressure upstream throttle not active
  • And
  • Choice of:
  • Barometric pressure > 73.00; < 107.50 kPa
  • Or
  • Barometric pressure sensor not active
P2300 Ignition Coil "A" Primary Control Circuit Low Ignition Coils Open Circuit
  • Output voltage in OFF state, lower range >= 1.92 - 2.21 V
  • Output voltage in OFF state, upper range (hardware values) <= 2.85 - 3.25 V
  • Engine speed > 512 RPM
  • ECT @ cylinder head > -30° C
  • Engine stop not active
  • 1.0 s
  • Continuous
  • 2 DCY
-- Check the Ignition Coils with Power Output Stage --. Refer to Ignition Coils with Power Output Stage --, CHECKING .
Ignition Coils Short To Ground
  • Output current in ON state (hardware values) > 50 - 100 mA
Ignition Coils Short To Battery Plus
  • Diagnosis by inactive low side: switch in ATIC:
  • Output voltage in OFF state (hardware values) > 4.95 - 5.285 V
  • Engine speed > 512 RPM
  • Engine stop not active
  • Actuator commanded off
  • Diagnosis by inactive low side: switch in ATIC:
  • Output temperature from ATIC in ON state > 160.0 - 200.0° C
  • Or
  • Output current in ON state (hardware values) driver stage internal value
  • Engine speed > 512 RPM
  • Engine stop not active
  • Actuator commanded on
P2303 Ignition Coil "B" Primary Control Circuit Low Ignition Coils Open Circuit
  • Output voltage in OFF state, lower range >= 1.92 - 2.21 V
  • Output voltage in OFF state, upper range (hardware values) <= 2.85 - 3.25 V
  • Engine speed > 512 RPM
  • ECT @ cylinder head > -30° C
  • Engine stop not active
  • 1.0 s
  • Continuous
  • 2 DCY
-- Check the Ignition Coils with Power Output Stage --. Refer to Ignition Coils with Power Output Stage --, CHECKING .
Ignition Coils Short To Ground
  • Output current in ON state (hardware values) > 50 - 100 mA
Ignition Coils Short To Battery Plus
  • Diagnosis by inactive low side: switch in ATIC:
  • Output voltage in OFF state (hardware values) > 4.95 - 5.285 V
  • Engine speed > 512 RPM
  • Engine stop not active
  • Actuator commanded off
  • Diagnosis by inactive low side: switch in ATIC:
  • Output temperature from ATIC in ON state > 160.0 - 200.0° C
  • Or
  • Output current in ON state (hardware values) driver stage internal value
  • Engine speed > 512 RPM
  • Engine stop not active
  • Actuator commanded on
P2306 Ignition Coil "C" Primary Control Circuit Low Ignition Coils Open Circuit
  • Output voltage in OFF state, lower range >= 1.92 - 2.21 V
  • Output voltage in OFF state, upper range (hardware values) <= 2.85 - 3.25 V
  • Engine speed > 512 RPM
  • ECT @ cylinder head > -30° C
  • Engine stop not active
  • 1.0 s
  • Continuous
  • 2 DCY
-- Check the Ignition Coils with Power Output Stage --. Refer to Ignition Coils with Power Output Stage --, CHECKING .
Ignition Coils Short To Ground
  • Output current in ON state (hardware values) > 50 - 100 mA
Ignition Coils Short To Battery Plus
  • Diagnosis by inactive low side: switch in ATIC:
  • Output voltage in OFF state (hardware values) > 4.95 - 5.285 V
  • Engine speed > 512 RPM
  • Engine stop not active
  • Actuator commanded off
  • Diagnosis by inactive low side: switch in ATIC:
  • Output temperature from ATIC in ON state > 160.0 - 200.0° C
  • Or
  • Output current in ON state (hardware values) driver stage internal value
  • Engine speed > 512 RPM
  • Engine stop not active
  • Actuator commanded on
P2309 Ignition Coil "D" Primary Control Circuit Low Ignition Coils Open Circuit
  • Output voltage in OFF state, lower range >= 1.92 - 2.21 V
  • Output voltage in OFF state, upper range (hardware values) <= 2.85 - 3.25 V
  • Engine speed > 512 RPM
  • ECT @ cylinder head > -30° C
  • Engine stop not active
  • 1.0 s
  • Continuous
  • 2 DCY
-- Check the Ignition Coils with Power Output Stage --. Refer to Ignition Coils with Power Output Stage --, CHECKING .
Ignition Coils Short To Ground
  • Output current in ON state (hardware values) > 50 - 100 mA
Ignition Coils Short To Battery Plus
  • Diagnosis by inactive low side: switch in ATIC:
  • Output voltage in OFF state (hardware values) > 4.95 - 5.285 V
  • Engine speed > 512 RPM
  • Engine stop not active
  • Actuator commanded off
  • Diagnosis by inactive low side: switch in ATIC:
  • Output temperature from ATIC in ON state > 160.0 - 200.0° C
  • Or
  • Output current in ON state (hardware values) driver stage internal value
  • Engine speed > 512 RPM
  • Engine stop not active
  • Actuator commanded on
P230A Cylinder 1 Air-Fuel Ratio Imbalance - Adjustment At Limit During Balance Fuel System A/F imbalance: rationality check
  • Cylinder misfire counter> 2.00[-]
  • Fuel pressure setpointnot calibratedkPa
  • Modeled catalyst temperature @ start<= 850° C
  • Lambda set value0.97 - 1.03[-]
  • Catalyst heatingnot active
  • Engine roughness signalvalid
  • Fuel cut offnot active
  • AAT>= -48° C
  • Barometric pressure>= 73.00 kPa
  • And
  • Min. injection timenot reached
  • And
  • Choice of:
  • Catalyst diagnosisn.a.
  • Or
  • Catalyst diagnosisn.a.
  • Depending on catalyst diagnosis:
  • Canister purge (conditions)n.a.
  • Or
  • Evap purge valven.a.
  • Or
  • Evap purgen.a.
  • And
  • O2S dynamic diagnosisn.a.
  • O2S delay diagnosisn.a.
  • Lambda controlclosed loop
  • Catalyst purgenot active
  • Canister load<= 2.00[-]
  • Engineno full load
  • Segment adaptationfinished
  • Catalyst damaging misfirenot detected
  • Emission threshold misfirenot detected
  • No gear switch for segments>= 90.00[-]
  • Segments after start> 0.00[-]
  • Time after engine start> 0.0[s]
  • Rough roadnot detected
  • And
  • Min. fuel mass>= 0.00[mg/rev]
  • Intake manifold runner flap position changenot active
  • Injection mode change (DFI/MFI)not equipped
  • Valve lift position changenot active
  • And
  • Depending on gear
  • 1st gearnot active
  • 2nd gear not active
  • 3rd gear not active
  • 4th gearactive
  • 5th gearactive
  • 6th gearactive
  • 7th gearactive
  • 8th gearnot active
  • And
  • Integrated air mass>= 1.00 - 12.00 kg
  • Diff. engine speed vs. dynamic engine speed< 200 rpm
  • Diff. air mass vs. dynamic air mass< 29.99 mg/rev
  • ECT @ cylinder head60 - 143° C
  • Adaptation cycles<= 255.00[-]
  • Engine speed1, 312 - 3, 008 rpm
  • And
  • Fuel mass setpoint lower range>= 11.00 mg/rev
  • Fuel mass setpoint upper range<= 32.00 mg/rev
  • 90 (does not run in FTP) s
  • Once / DCY
  • 2 DCY
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
P230B Cylinder 2 Air-Fuel Ratio Imbalance - Adjustment At Limit During Balance Fuel System A/F imbalance: rationality check
  • Cylinder misfire counter> 2.00[-]
  • Fuel pressure setpointnot calibrated kPa
  • Modeled catalyst temperature @ start<= 850° C
  • Lambda set value0.97 - 1.03[-]
  • Catalyst heatingnot active
  • Engine roughness signalvalid
  • Fuel cut offnot active
  • AAT>= -48° C
  • Barometric pressure>= 73.00 kPa
  • And
  • Min. injection timenot reached
  • And
  • Choice of:
  • Catalyst diagnosisn.a.
  • Or
  • Catalyst diagnosisn.a.
  • Depending on catalyst diagnosis:
  • Canister purge (conditions)n.a.
  • Or
  • Evap purge valven.a.
  • Or
  • Evap purgen.a.
  • And
  • O2S dynamic diagnosisn.a.
  • O2S delay diagnosisn.a.
  • Lambda controlclosed loop
  • Catalyst purgenot active
  • Canister load<= 2.00[-]
  • Engineno full load
  • Sgment adaptationfinished
  • Catalyst damaging misfirenot detected
  • Emission threshold misfirenot detected
  • No gear switch for segments>= 90.00[-]
  • Segments after start> 0.00[-]
  • Time after engine start> 0.0 s
  • Rough roadnot detected
  • And
  • Min. fuel mass>= 0.00 mg/rev
  • Intake manifold runner flap position changenot active
  • Injection mode change (DFI/MFI)not equipped
  • Valve lift position changenot active
  • And
  • Depending on gear
  • 1st gearnot active
  • 2nd gearnot active
  • 3rd gearnot active
  • 4th gearactive
  • 5th gearactive
  • 6th gearactive
  • 7th gearactive
  • 8th gearnot active
  • And
  • Integrated air mass>= 1.00 - 12.00 kg
  • Diff. engine speed vs. dynamic engine speed< 200 rpm
  • Diff. air mass vs. dynamic air mass< 29.99 mg/rev
  • ECT @ cylinder head60 - 143° C
  • Adaptation cycles<= 255.00[-]
  • Engine speed1, 312 - 3, 008 rpm
  • And
  • Fuel mass setpoint lower range>= 11.00 mg/rev
  • Fuel mass setpoint upper range<= 32.00 mg/rev
  • 90 (does not run in FTP) s
  • Once / DCY
  • 2 DCY
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
P230C Cylinder 3 Air-Fuel Ratio Imbalance - Adjustment At Limit During Balance Fuel System A/F imbalance: rationality check
  • Cylinder misfire counter> 2.00[-]
  • Fuel pressure set point not calibratedkPa
  • Modeled catalyst temperature @ start<= 850° C
  • Lambda set value0.97 - 1.03[-]
  • Catalyst heatingnot active
  • Engine roughness signalvalid
  • Fuel cut offnot active
  • AAT>= -48° C
  • Barometric pressure>= 73.00 kPa
  • And
  • Min. injection timenot reached
  • And
  • Choice of:
  • Catalyst diagnosisn.a.
  • Or
  • Catalyst diagnosisn.a.
  • Depending on catalyst diagnosis:
  • Canister purge (conditions)n.a.
  • Or
  • Evap purge valven.a.
  • Or
  • Evap purgen.a.
  • And
  • O2S dynamic diagnosisn.a.
  • O2S delay diagnosisn.a.
  • Lambda controlclosed loop
  • Catalyst purgenot active
  • Canister load<= 2.00[-]
  • Engineno full load
  • Segment adaptationfinished
  • Catalyst damaging misfirenot detected
  • Emission threshold misfirenot detected
  • No gear switch for segments>= 90.00[-]
  • Segments after start> 0.00[-]
  • Time after engine start> 0.0 s
  • Rough roadnot detected
  • And
  • Min. fuel mass>= 0.00 mg/rev
  • Intake manifold runner flap position changenot active
  • Injection mode change (DFI/MFI)not equipped
  • Valve lift position changenot active
  • And
  • Depending on gear
  • 1st gearnot active
  • 2nd gearnot active
  • 3rd gearnot active
  • 4th gearactive
  • 5th gearactive
  • 6th gearactive
  • 7th gearactive
  • 8th gearnot active
  • And
  • Integrated air mass>= 1.00 - 12.00 kg
  • Diff. engine speed vs. dynamic engine speed< 200rpm
  • Diff. air mass vs. dynamic air mass< 29.99 mg/rev
  • ECT @ cylinder head60 - 143° C
  • Adaptation cycles<= 255.00[-]
  • Engine speed1, 312 - 3, 008 rpm
  • And
  • Fuel mass setpoint lower range>= 11.00 mg/rev
  • Fuel mass setpoint upper range<= 32.00 mg/rev
  • 90 (does not run in FTP) s
  • Once / DCY
  • 2 DCY
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
P230D Cylinder 4 Air-Fuel Ratio Imbalance - Adjustment At Limit During Balance Fuel System A/F imbalance: rationality check
  • Cylinder misfire counter> 2.00[-]
  • Fuel pressure setpointnot calibrated kPa
  • Modeled catalyst temperature @ start<= 850° C
  • Lambda set value0.97 - 1.03[-]
  • Catalyst heatingnot active
  • Engine roughness signalvalid
  • Fuel cut offnot active
  • AAT>= -48° C
  • Barometric pressure>= 73.00 kPa
  • And
  • Min. injection timenot reached
  • And
  • Choice of:
  • Catalyst diagnosisn.a.
  • Or
  • Catalyst diagnosisn.a.
  • Depending on catalyst diagnosis:
  • Canister purge (conditions)n.a.
  • Or
  • Evap purge valven.a.
  • Or
  • Evap purgen.a.
  • And
  • O2S dynamic diagnosisn.a.
  • O2S delay diagnosisn.a.
  • Lambda controlclosed loop
  • Catalyst purgenot active
  • Canister load<= 2.00[-]
  • Engineno full load
  • Segment adaptationfinished
  • Catalyst damaging misfirenot detected
  • Emission threshold misfirenot detected
  • No gear switch for segments>= 90.00[-]
  • Segments after start> 0.00[-]
  • Time after engine start> 0.0 s
  • Rough roadnot detected
  • And
  • Min. fuel mass>= 0.00mg/rev
  • Intake manifold runner flap position changenot active
  • Injection mode change (DFI/MFI)not equipped
  • Valve lift position changenot active
  • And
  • Depending on gear
  • 1st gearnot active
  • 2nd gearnot active
  • 3rd gearnot active
  • 4th gearactive
  • 5th gearactive
  • 6th gearactive
  • 7th gearactive
  • 8th gearnot active
  • And
  • Integrated air mass>= 1.00 - 12.00 kg
  • Diff. engine speed vs. dynamic engine speed< 200 rpm
  • Diff. air mass vs. dynamic air mass< 29.99 mg/rev
  • ECT @ cylinder head60 - 143° C
  • Adaptation cycles<= 255.00[-]
  • Engine speed1, 312 - 3, 008 rpm
  • And
  • Fuel mass setpoint lower range>= 11.00 mg/rev
  • Fuel mass setpoint upper range<= 32.00 mg/rev
  • 90 (does not run in FTP) s
  • Once / DCY
  • 2 DCY
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
P2414 O2 Sensor Exhaust Sample Error Bank 1 Sensor 1 Oxygen Sensors Front Rationality Check
  • Pump current correction (nernst-cell) > 1.2 mA
  • O2S front ready
  • Fuel cut off not active
  • Cylinder shut off not active
  • Depending on engine state:
  • Engine part load
  • Or
  • Engine full load
  • Or
  • Engine idle for time >= 3.0 s
  • 10.0 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter -GX10-, CHECKING .
P2431 AIR System Air Flow/Pressure Sensor Circuit Range/Performance Bank 1 Secondary Air System Pressure Sensor Rationality Check
  • Difference between AIR pressure and barometric pressure > 6.0 kPa
  • And
  • Difference between AIR pressure and intake manifold pressure > 6.0 kPa
  • Engine stop
  • For time > 0.0 s
  • 0.1 s
  • Once / DCY
  • 2 DCY
-- Check the Secondary Air System -GX24-. Refer to Secondary Air Injection Sensor 1 -G609- / Secondary Air Injection Solenoid Valve -N112-, CHECKING .
P2432 AIR System Air Flow/Pressure Sensor Circuit Low Bank 1 Secondary Air System Pressure Sensor Out Of Range Low
  • Sensor voltage < 0.50 V
 
  • 0.1 s
  • Continuous
  • 2 DCY
-- Check the Secondary Air System -GX24-. Refer to Secondary Air Injection Sensor 1 -G609- / Secondary Air Injection Solenoid Valve -N112-, CHECKING .
P2433 AIR System Air Flow/Pressure Sensor Circuit High Bank 1 Secondary Air System Pressure Sensor Out Of Range High
  • Sensor voltage > 4.50 V
 
  • 0.1 s
  • Continuous
  • 2 DCY
-- Check the Secondary Air System -GX24-. Refer to Secondary Air Injection Sensor 1 -G609- / Secondary Air Injection Solenoid Valve -N112-, CHECKING .
P2440  AIR System Switching Valve Stuck Open Bank 1 Secondary Air Valve Functional Check
  • Ratio relative pressure phase 1 and relative pressure phase 2 > 1.34 [-]
  • General:
  • Secondary air pump active
  • Catalyst heating active
  • Secondary air injection active
  • MAF <= 140.0 kg/h
  • ECT @ cylinder head >= -10; < 115° C
  • IAT @ manifold >= -10; < 100° C
  • Modeled catalyst temperature < 900° C
  • Relative barometric pressure > 0.73 [-]
  • And
  • Diff. barometric pressure vs. manifold pressure > n.a. kPa
  • Or
  • Engine n.a.
  • 0.1 s
  • Once / DCY
  • 2 DCY
-- Check the Secondary Air System -GX24-. Refer to Secondary Air Injection Sensor 1 -G609- / Secondary Air Injection Solenoid Valve -N112-, CHECKING .
P2556 Engine Coolant Level Sensor/Switch Circuit Rotary Coolant Valve Communication Check
  • Communication signal failure
 
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Engine Temperature Control Actuator -N493-. Refer to Engine Temperature Control Actuator -N493-, CHECKING .
Rotary Coolant Valve Signal Check
  • Sensor signal failure
P2557 Engine Coolant Level Sensor/Switch Circuit Range/Performance Rotary Coolant Valve Checksum Verification
  • Checksum signal failure
 
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Engine Temperature Control Actuator -N493-. Refer to Engine Temperature Control Actuator -N493-, CHECKING .
P2564 Turbocharger Boost Control Position Sensor "A" Circuit Low Turbocharger Boost Control Position Sensor Short To Ground / Open Circuit
  • Turbocharger boost control position sensor voltage < 0.20 V
 
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Charge Pressure Actuator -V465- / Charge Pressure Actuator Position Sensor -G581-. Refer to Charge Pressure Actuator -V465- / Charge Pressure Actuator Position Sensor -G581-, CHECKING ..
P2565 Turbocharger Boost Control Position Sensor "A" Circuit High Turbocharger Boost Control Position Sensor Short To Battery Voltage
  • Turbocharger boost control position sensor voltage > 4.80 V
 
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Charge Pressure Actuator -V465- / Charge Pressure Actuator Position Sensor -G581-. Refer to Charge Pressure Actuator -V465- / Charge Pressure Actuator Position Sensor -G581-, CHECKING .
P2610 ECM/PCM Engine Off Timer Performance Engine Off Time ECM Internal Timer Check
  • ECM internal timerfailure
  • Or
  • ECM internal timer signalnot calibrated
  • ECM internal timernot calibrated
  • Time after last engine stop not calibrated
  • SPI initialization finished
  • 1.3 s
  • Continuous
  • 2 DCY
-- Check the Engine Control Module -J623-. Refer to appropriate repair information.
Engine Off Time ECM Rationality Check
  • Difference between engine-off-time and ECM keep alive-time >= 12.0 s
  • Or
  • Difference between ECM keep alive-time and engine-off-time>= 12.0s
  • Monitor Entry Conditions:
  • ECM keep alive-time active
  • ECU internal timer reset not activated
  • Time delay >= 1.0 s
  • Time after last engine stop< 48[h]
  • Case 1:
  • For time (after entry conditions fulfilled)>= 65 s
  • Case 2:
  • For time (after entry conditions fulfilled)< 65 s
  • Ignition keytransition off to on
  • 10 ms
  • Once / DCY
  • Difference between engine-off-time and ECM keep alive-time >= 12.0 s
  • Time after engine stop < 86, 400.0 s
  • Engine off time plausible
  • Engine off time monitoring not finished
  • Engine off time signal valid time after reset < 2.0 s
  • And
  • Case 1:
  • Engine off timer n.a.
  • Or
  • Engine off time n.a.
  • Case 2:
  • ECM internal timer active
  • SPI communication failure after reset detected
P2635 Fuel Pump Control Module Performance COM: Fuel Pump Control Module (FPCM) communication with FPCM
  • FP signal: overcurrent failure feedback>= 2.00[-]
  • Engine on
  • 1.6 s
  • Continuous
  • 2 DCY
-- Check the Fuel Pump Control Module -J538-. Refer to Fuel Pump Control Module -J538- /Fuel Delivery Unit -GX1-, CHECKING
  • FP signal: rotary failure feedback>= 2.00[-]
  • 1.8 s
  • Continuous
  • FP sensor: short to battery failure or rpm deviation feedback>= 2.00[-]
  • 2.4 s
  • Continuous
P2681 Engine Coolant Bypass Valve "A" Control Circuit/Open Rotary Coolant Valve Open Circuit
  • Load resistance > 200.0 kOhm
  • Rotary slide valve commanded off
  • 1.3 s
  • Continuous
  • 2 DCY
-- Check the Engine Temperature Control Actuator -N493-. Refer to Engine Temperature Control Actuator -N493-, CHECKING ..
P2682 Engine Coolant Bypass Valve "A" Control Circuit Low Rotary Coolant Valve Short To Ground Output 1
  • High side current output 1 driver stage internal value
  • Rotary slide valve commanded on
  • Rotary valve direction forward
  • 0.30 s
  • Continuous
  • 2 DCY
-- Check the Engine Temperature Control Actuator -N493-. Refer to Engine Temperature Control Actuator -N493-, CHECKING .
Rotary Coolant Valve Short To Ground Output 2
  • High side current output 2 driver stage internal value
  • Rotary slide valve commanded on
  • Rotary valve direction reversed
P2683 Engine Coolant Bypass Valve "A" Control Circuit High Rotary Coolant Valve Short To Battery Plus Output 1
  • Low side current output 1 driver stage internal value
  • Rotary slide valve commanded off
  • 0.30 s
  • Continuous
  • 2 DCY
-- Check the Engine Temperature Control Actuator -N493-. Refer to Engine Temperature Control Actuator -N493-, CHECKING .
Rotary Coolant Valve Short To Battery Plus Output 2
  • Low side current output 2 driver stage internal value
  • Rotary slide valve commanded off
P334A Charge Pressure Actuator Electrical Error Turbocharger Boost Pressure Control Valve Short To Ground
  • Bypass valve driver current driver stage internal value
  • Boost pressure actuator controller active
  • 0.4 s
  • Continuous
  • 2 DCY
-- Check the Charge Pressure Actuator -V465- / Charge Pressure Actuator Position Sensor -G581-. Refer to Charge Pressure Actuator -V465- / Charge Pressure Actuator Position Sensor -G581-, CHECKING .
U0001 High Speed CAN Communication Bus CAN: Powertrain BUS reading back sent message Powertrain
  • Message no feedback
  • Time after ignition on 0.5 s
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the CAN-Bus circuits. If there are any other DTC's present check them first.-- Refer to the proper wiring schematic for terminal and component location.
U0002 High Speed CAN Communication Bus Performance CAN: Powertrain BUS communication check Powertrain
  • Global time outreceiving no message
  • Time after ignition on 0.5 s
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the CAN-Bus circuits. If there are any other DTC's present check them first.-- Refer to the proper wiring schematic for terminal and component location.
U0101 Lost Communication with TCM CAN: Transmission Control Module (TCM) CAN Communication With TCM
  • Received message from TCM no message
  • Time after ignition on 0.5 s
  • 1.0 s
  • 2 DCY
-- Check the CAN-Bus circuits. If there are any other DTC's present check them first.-- Refer to the proper wiring schematic for terminal and component location.
U0121 Lost Communication With Anti-Lock Brake System (ABS) Control Module CAN: Brake System Control Module (BSCM) communication with BSCM
  • Received CAN message no message
  • Time after ignition on 0.5 s
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the CAN-Bus circuits. If there are any other DTC's present check them first.-- Refer to the proper wiring schematic for terminal and component location.
U0140 Lost Communication With Body Control Module CAN: Body Control Module (BCM) CAN Communication With Body Control Module
  • Received CAN message no message
  • Time after ignition on 0.5 s
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the CAN-Bus circuits. If there are any other DTC's present check them first.-- Refer to the proper wiring schematic for terminal and component location.
U0146 Lost Communication With Gateway "A" CAN: Gateway CAN Communication With Gateway
  • Message no message
  • Time after ignition on 0.5 s
  • 1.0 s
  • Continuous
  • 2 DCY
-- Check the CAN-Bus circuits. If there are any other DTC's present check them first.-- Refer to the proper wiring schematic for terminal and component location.
U0155 Lost Communication With Instrument Panel Cluster (IPC) Control Module CAN: Instrument Cluster CAN Communication With Instrument Cluster Module
  • Message no message
  • Time after ignition on 0.5 s
  • 5.0 s
  • Continuous
  • 2 DCY
-- Check the CAN-Bus circuits. If there are any other DTC's present check them first.-- Refer to the proper wiring schematic for terminal and component location.
U0302 Software Incompatibility With Transmission Control Module COM: Transmission Control Module (TCM) communication with TCM
  • Received AT vehicle data from TCM, TCM signal
  • Time after ignition on0.5 s
  • 5.0 s
  • Continuous
  • 2 DCY
-- Check for software updates and TSB's. Reprogram as necessary. If none are found, refer to appropriate repair information.
U0322 Software Incompatibility With Body Control Module CAN: Gateway CAN Communication With Gateway
  • Ambient temperature sensor coding monitoring failure
  • Time after ignition on > 1.5 s
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the CAN-Bus circuits. If there are any other DTC's present check them first. -- Refer to the proper wiring schematic for terminal and component location.
U0415 Invalid Data Received From Anti-Lock Brake System (ABS) Control Module Vehicle Speed Rationality Check High
  • Vehicle speed > 202 mph
 
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the CAN-Bus circuits. If there are any other DTC's present check them first. -- Refer to appropriate repair information for the ABS.-- Refer to the proper wiring schematic for terminal and component location.
CAN: Vehicle Speed Sensor CAN communication with BSCM
  • Speed sensor signal: sensor error=655, 35km/h (no map, just bottom and top limit)
  • Time since engine on > 0.5 s
  • 0.5 s
  • Continuous
  • Speed sensor signal: initialization error=655, 33 - 655, 34 km/h (no map, just bottom and top limit)
  • Time since engine on > 0.5 s
  • Vehicle speed < 7 mph
  • 2.0 s
  • Continuous
  • speed sensor signal: low voltage error=655, 33 - 655, 34km/h (no map, just bottom and top limit)
  • Time since engine on > 0.5 s
  • Vehicle speed > 7 mph
  • 0.5 s
  • Continuous
CAN: Brake System Control Module (BSCM) CAN Communication With Brake Unit
  • Received data from TCS implausible message
  • Time after ignition on 0.5 s
  • 0.5 s
  • Continuous
U0422 Invalid Data Received From Body Control Module CAN: Gateway CAN communication with BCM
  • Received data from BCMimplausible message
  • Time after ignition on 0.5 s
  • 1.0 s
  • Continuous
  • 2 DCY
-- Check the Outside Air Temperature Sensor -G17-. Refer to Outside Air Temperature Sensor -G17-, CHECKING .-- Check the CAN-Bus circuits. If there are any other DTC's present check them first.-- Refer to the proper wiring schematic for terminal and component location.
  • Ambient temperature value (initialization)failure
  • Time after ignition on> 1.5 s
  • Enginerunning
  • 3.0 s
  • Continuous
  • 2 DCY
U0423 Invalid Data Received From Instrument Panel Cluster Control Module CAN: Instrument Cluster CAN Communication With Instrument Cluster Module
  • Received data from Instrument Cluster implausible message
  • Time after ignition on 0.5 s
  • 3.0 s
  • Continuous
  • 2 DCY
-- Check the CAN-Bus circuits. If there are any other DTC's present check them first.-- Refer to the proper wiring schematic for terminal and component location.
U1103 Production Mode Active ECM: Production Mode Function Monitoring: Mode Change
  • Production mode active
  • Vehicle speed < 3 mph
  • Max trip mileage since initial vehicle start-up < 62.15 miles
  • During ECM keep alive-time after ignition off engine speed 0 rpm
For hybrid:
  • Drive motor off
  • 0.01 s
  • Continuous
  • 1DCY
-- PERFORM: Preliminary Check to verify the concern. Refer to PRELIMINARY CHECK .-- Perform readiness check. Refer to READINESS CODES .