| P2400 |
Evaporative Emission System Leak Detection Pump Control Circuit/Open |
-- Check the Leak Detection Pump (LDP) -V144-. Refer to LEAK DETECTION PUMP, CHECKING . |
Signal voltage > 4.40... 5.60 V |
- Pump, Commanded off
- Engine speed, >80 RPM
|
0.5 Sec |
|
| P2401 |
Evaporative Emission System Leak Detection Pump Control Circuit Low |
-- Check the Leak Detection Pump (LDP) -V144-. Refer to LEAK DETECTION PUMP, CHECKING . |
Signal voltage < 2.15-3.25 V |
- Pump, Commanded off
- Engine speed, >80 RPM
|
0.5 Sec |
|
| P2402 |
Evaporative Emission System Leak Detection Pump Control Circuit High |
-- Check the Leak Detection Pump (LDP) -V144-. Refer to LEAK DETECTION PUMP, CHECKING . |
Signal current > 3.0 A |
- Pump, Commanded on
- Engine speed, >80 RPM
|
0.5 Sec |
|
| P2403 |
Evaporative Emission System Leak Detection Pump Sense Circuit/Open |
-- Check the Leak Detection Pump (LDP) -V144-. Refer to LEAK DETECTION PUMP, CHECKING . |
Low signal voltage > 0.5 Sec |
- Time after engine start 5...65530 Sec.
- ECT, 4...120° C
- ECT at start, 4...50° C
- engine off time, >21600 Sec
- ambient air temp 4...59° C
- Altitude, < 2700 m
- integrated purge flow, >12.10 g
- restart temp difference, >0.0 K
- Vehicle speed, > 40 km/h once Selected gear, Any drive
- Evap purge valve, ready no fault
- LDP, commanded off
|
0 Sec |
|
| P2404 |
Evaporative Emission System Leak Detection Pump Sense Range/Performance |
-- Check the Leak Detection Pump (LDP) -V144-. Refer to LEAK DETECTION PUMP, CHECKING . |
- High signal voltage > 12 Sec
- AND
- number of checks, 30.0
AND
- cumulative time of high signal voltage during pumping > 50 Sec
|
- Time after engine start 5...65530 Sec.
- ECT, 4...120° C
- ECT at start, 4...50° C
- engine off time, >21600 Sec
- ambient air temp 4...59° C
- Altitude, < 2700 m
- intake manifold vacuum, > 2560hPa
- restart temp difference, >0.0 K
- Vehicle speed, > 40 km/h once Selected gear, Any drive
- Evap purge valve, closed, ready, no fault
- LDP, commanded on
|
|
|
| P2414 |
O2 Sensor Exhaust Sample Error Bank 1, Sensor 1 |
-- Check the Heated Oxygen Sensor (HO2S) -G39-. Refer to HEATED OXYGEN SENSOR HO2S, CHECKING . |
Threshold 1
- Signal voltage 3.10...4.81 V
Threshold 2
- Signal Voltage 2.5...3.10 V
|
- lambda set value, < 1.6
- O2S ceramic temp.,> 715.00° C
- fuel cut off, not active
- heater control, closed loop
- SAI, not active
- if low fuel signal then wait, > 600.00 Sec
|
|
|
| P2431 |
rationality check |
Check the Secondary Air System. Refer to appropriate service information. |
difference between SAI pressure and ambient pressure, NOT -25.0...25.00 hPa |
--- |
0.50 Sec |
|
| P2432 |
signal range check |
Check the Secondary Air System. Refer to appropriate service information. |
signal voltage, <.40 V |
--- |
0.50 Sec |
|
| P2433 |
signal range check |
Check the Secondary Air System. Refer to appropriate service information. |
signal voltage, >4.65 V |
--- |
0.50 Sec |
|
| P2440 |
system check after SAI PZEV only |
Check the Secondary Air System. Refer to appropriate service information. |
SAI pressure meadured with SAI pressure sensor vs modeled while SAI valve closed. <0.55% |
- ECT, 5...39° C
- IAT, 5...40° C
- altitude, <2700m
- SAI pressure sensor, ready no fault
|
|
|
| P2539 |
Low Pressure Fuel System Sensor Circuit |
-- Check the Fuel Pressure Sensor -G247-. Refer to FUEL PRESSURE SENSOR, CHECKING . |
Signal voltage > 4.9 V |
--- |
1 Sec |
|
| P2540 |
Low Pressure Fuel System Sensor Circuit Range/Performance |
-- Check the Fuel Pressure Sensor -G247-. Refer to FUEL PRESSURE SENSOR, CHECKING . |
Actual pressure Deviation < 800 kPa <80 kPa |
--- |
5 Sec |
|
| P2541 |
Low Pressure Fuel System Sensor Circuit Low |
-- Check the Fuel Pressure Sensor -G247-. Refer to FUEL PRESSURE SENSOR, CHECKING . |
Signal voltage < 0.2 V |
--- |
1 Sec |
|
| P2626 |
O2 Sensor Pumping Current Trim Circuit/Open Bank 1 Sensor 1 |
-- Check the Heated Oxygen Sensor (HO2S) -G39-. Refer to HEATED OXYGEN SENSOR HO2S, CHECKING . |
|
- Modeled exhaust temp, <750° C
- O2S ceramic temp, >715° C
- Fuel cut off, Active
- heater control, closed loop
- if low fuel signal, then wait, > 600 Sec
|
|
|