Installed Calibration ToolVAS6350 Overview

Fig 1: Identifying VAS 6350
GWWA91-10994Courtesy of AUDI OF AMERICA, LLC
  1. Calibration Tool - Wheel Center MountingsVAS6350/1
  2. Calibration Tool - Wheel Center MountingsVAS6350/1
  3. Right Angle Bracket
    • Calibration Tool - Spacing LaserVAS6350/2 mount
  4. Plastic Foot
    • Three on underside of calibration platform
    • Adjustable for aligning horizontal position of calibration platform
  5. Linear LaserVAS6350/3A
    • On the calibration board
    • Switching on and off, refer to operating instructions.
  6. Calibration Tool - Spacing LaserVAS6350/2
    • On the calibration board
    • Notes on operation, refer to operating instructions.
  7. Level
    • On the calibration board
    • For checking the horizontal position
  8. Left Angle Bracket
    • Calibration Tool - Spacing LaserVAS6350/2 mount
  9. Calibration Board
    • Between the mounts on the calibration board and the Calibration Tool - Wheel Center MountingsVAS6350/1 -dimension A- 1.47 m through 1.90 m

Calibration Board Alignment

-- Position the calibration platform behind the vehicle at a distance of 1.47 m to 1.90 m to the rear wheels, see -dimension A- in the illustration, refer to Installed Calibration ToolVAS6350 Overview .

-- Bring the Calibration ToolVAS6350 into a horizontal position.

-- To do this, twist plastic feet under calibration device so that air bubble in level is located exactly in the center of the indicator -arrow-.

Fig 2: Identifying Bubble Level (Sight Glass) On Calibration Tool VAS 6350
GWWN94-10686Courtesy of AUDI OF AMERICA, LLC
WARNING:

Make sure light does not reflect off the calibration platform.

Reflections affect the Rearview Camera -R189- and may make it impossible to perform the calibration.

-- Switch on the Linear LaserVAS6350/3A -1- on the calibration board and adjust the entire Calibration ToolVAS6350 so that the laser beam hits the center of vehicle rear above the Audi rings.

Fig 3: Switching On Line Laser VAS6350/3
GWWA91-10995Courtesy of AUDI OF AMERICA, LLC

-- Make sure the Audi rings are centered on the rear. Correct the laser beam accordingly.