Home >> Audi >> 2012 >> A7 >> Repair and Diagnosis >> External Pages >> Different car >> Section 73 (Communication System (Service Information)) >> Communication >> Peripheral Camera >> Peripheral Camera System, Calibrating >> Calibration Tool:VAS6350 WITH Calibration Tool - Peripheral Camera:VAS6350/6Calibration Tool - Peripheral Camera:VAS6350/6, INSTALLING AND ALIGNING

Calibration Tool:VAS6350 WITH Calibration Tool - Peripheral Camera:VAS6350/6Calibration Tool - Peripheral Camera:VAS6350/6, INSTALLING AND ALIGNING

WARNING: This page does not describe the selected car, but rather 9 other vehicles, including the 2018 Audi S7, 2018 Audi RS 7, 2018 Audi A7 Quattro, 2017 Audi S7, and 2017 Audi RS 7. However, it is still accessible from the selected car via links, so may be relevant.

After performing service work on the vehicle, it may be necessary to calibrate the peripheral camera system. In detail, this is the case after:

All cameras must be calibrated if the Peripheral Camera Control Module -J928- is replaced.

Calibration Requirements 

Calibrate the cameras in the following sequence:

Special Tools And Workshop Equipment Required 

The :VAS6350  consists of the following parts:

The :VAS6350/6  is comprise of the following components:

Overview :VAS6350  with :VAS6350/6 

The :VAS6350/6-1  and :VAS6350/6-2  must be vertical.

-- Move the calibration field on the :VAS6350/6  into a horizontal position.

-- To do so, twist plastic feet under the calibration field of the :VAS6350  so that air bubble in level is located exactly in the center of the indicator -arrow-

GWWN94-10686Courtesy of AUDI OF AMERICA, LLC
WARNING:

Make sure light does not reflect off the :VAS6350/6  .

Reflections affect the camera and may make it impossible to perform the calibration.

-- Set the :VAS6350/6-1  -1- and the :VAS6350/6-2  -2- on both sides to the dimension -B- 77.5 of the scale on the :VAS6350  .

GWWA91-12412Courtesy of AUDI OF AMERICA, LLC

-- Adjust the height of the :VAS6350/6-1  -1- and :VAS6350/6-2  -2- so that dimension -A- is 150 mm between the lower edge of the black measuring field (not of the aluminum frame!) and the surface of the :VAS6350  calibration field.

The corners on the outside of the :VAS6350  calibration field must always be flush with the outer edge of the black line on the measuring field when performing distance measuring.

Layout of :VAS6350  with :VAS6350/6 

GWWA91-11959Courtesy of AUDI OF AMERICA, LLC
  1. Positioning the Front Peripheral Camera -R243- for Calibrating
  2. Front Peripheral Camera -R243-
  3. Right Peripheral Camera -R245-
  4. Positioning the Right Peripheral Camera -R245- for Calibrating
  5. Rear Peripheral Camera -R246-
  6. Positioning the Rear Peripheral Camera -R246- for Calibrating
  7. Positioning the Left Peripheral Camera -R244- for Calibrating
  8. Left Peripheral Camera -R244-
WARNING:

Make sure light does not reflect off the :VAS6350/6  .

Reflections affect the camera and may make it impossible to perform the calibration.