Intake Manifold Runner Control Valve -N316-, Checking: Notes
GENERAL DESCRIPTION
The Intake Manifold Runner Valve(s) Are Mounted On A Common Shaft And Actuated By A Vacuum Cell. The Partial Vacuum Required For Actuation Is Supplied By The Intake Manifold Runner Control Valve -N316-. The Engine Control Module -J623- Activates The Intake Manifold Runner Control Valve -N316- On The Basis Of A Characteristic Map.
Special Tools And Workshop Equipment Required
- Multimeter.
- Wiring Diagram.
- Scan Tool.
TEST REQUIREMENTS
- Fuses OK.
- Battery voltage OK.
- Switch OFF All electrical and electronic accessories.
- Vehicles with Auto. Transmission, ensure Selector Lever position is in "P".
- Vehicles with Manual Transmission, ensure Shifter Lever position is in "N" with Parking Brake applied.
- Observe all safety precautions: SAFETY PRECAUTIONS .
- View clean working conditions: CLEAN WORKING CONDITIONS .
- For Hybrid vehicles refer to: HIGH VOLTAGE SYSTEM GENERAL WARNINGS .