Mode 5: Check oxygen sensor output signals: Procedure

NOTE:
  • Bank 1 = cylinder bank 1 in direction of travel, right; Bank 2 = cylinder bank 2 in direction of travel, left.
  • When selecting the diagnostic mode, the entry is always performed in "Bank 1 sensor 1".
  • If either the VAG1551/1552 Scan Tool (ST) or VAS5051/5052 Vehicle Diagnostic, Testing and Information System is used for checking the output of oxygen sensor signals, the respective oxygen sensor can be selected by pressing button 1, 2, 5 and 6:
    1. - Button 1 = Bank 1 sensor 1,
    2. - Button 2 = Bank 1 sensor 2,
    3. - Button 5 = Bank 2 sensor 1,
    4. - Button 6 = Bank 2 sensor 2.
MODE 5: OXYGEN SENSOR SIGNALS

Test-ID(1) Diagnostic text Evaluation
01: Rich to lean sensor barrier voltage EVALUATION TEST-ID 01: RICH TO LEAN SENSOR BARRIER VOLTAGE 
02: Lean to rich sensor barrier voltage EVALUATION TEST-ID 01: RICH TO LEAN SENSOR BARRIER VOLTAGE 
07: Minimum voltage at sensor for test cycle EVALUATION TEST-ID 07: MINIMUM VOLTAGE AT SENSOR FOR TEST CYCLE 
08: Maximum voltage at sensor for test cycle EVALUATION TEST-ID 08: MAXIMUM VOLTAGE AT SENSOR FOR TEST CYCLE 
129: Current value of oxygen sensor signal  
130: Specified value of oxygen sensor signal  
131: Dynamic value  
132: Shift of oxygen sensor regulation before catalytic converter via oxygen sensor regulation behind catalytic converter  