Basic setting
With engine stopped and ignition switched on, the following operation can be carried out with the "Function 04" basic setting:
- Adaptation of the Throttle Drive Control to the Engine Control Module (ECM). Refer to Display group 060 (Refer to Throttle Valve Control Module -J338-, adapting )
- Vehicles with automatic transmission: Adaptation of kick-down function of Throttle Position (TP) Sensor to Engine Control Module (ECM). Refer to Display group 063 (Refer to Kick-down function, adapting )
With the engine running, the following operations can be performed with the basic setting function:
- Generation of readiness code. Refer to Readiness code, generating
- Performance of Oxygen Sensor (O2S) and Oxygen Sensor control (Refer to Oxygen Sensor (O2S) and Oxygen Sensor control before catalytic converter, checking )
Conditions for operations with engine running
- No DTCs stored in Diagnostic Trouble Code (DTC) memory
- Coolant temperature at least 80 ° C.
- Electrical devices switched off (coolant fan must not run during the test).
- Air conditioning switched off.
- Vehicles with automatic transmission: Selector lever in position P or N.
Work sequence
- Connect VAS 5051 tester. Refer to VAS 5051 vehicle diagnostic, testing and information system, connecting and selecting functions and select vehicle system "01 - Engine electronics". Ignition must be switched on for this.
or, depending on desired operation:
- Start engine.
Display on VAS 5051:
- In selection -1-, click on diagnostic function "04 - Basic Setting".
Display on VAS 5051:
1 - Enter display group
- Enter desired 3-digit display group number in button field -2- and press -Q- button to confirm input.
Example:
- Press buttons -0-, -0- and -1- to select "display group number 001" and press -Q- button to confirm input.
Display on VAS 5051:
1 - Measured values not in basic setting
2 - Measured values in basic setting
3 - Display group X
A - Activating basic setting
NOTE:
Basic setting is initiated after button -A- is pressed.
Display on VAS 5051:
1 - Display field 1
2 - Display field 2
3 - Display field 3
4 - Display field 4
- End function "04 - Basic setting" by pressing ← button.