A/C refrigerant system, leak testing
WARNING: This page does not describe the selected car, but rather 15 other vehicles, including the 2005 Audi allroad, 2004 Audi allroad, 2004 Audi A6, 2003 Audi allroad, and 2003 Audi S6. However, it is still accessible from the selected car via links, so may be relevant.
- Use halogen leak detector Hitec HI400A-TEL or equivalent to check for refrigerant leaks.
- Refrigerant gas dissipates very quickly. Avoid drafty or windy areas when checking for leaks.
- Some refrigerant leaks are apparent by refrigerant oil deposits on or near leak location. Confirm by using leak detector.
- If the refrigerant system is discharged (empty), charge system with approx. 100 g (3.5 oz) of refrigerant in order to check for leaks.
- Check refrigerant system for leaks following leak detector manufacturer's instructions.
- Check for refrigerant leaks by passing detector probe under suspected leaking components.
NOTE:
Refer to leak detector manufacturer's instructions.