Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Acura >> 2023 >> Integra Base, Automatic CVT Trans >> Repair and Diagnosis >> Engine Performance >> System >> Engine Control System Diagnostics (P0010 - P0121) >> Troubleshooting >> DTC P0035 (1.5L Engine) >> ABV Open Wire Inspection

ABV Open Wire Inspection

NOTICE: 

Before disconnecting the PCM connector, jump the SCS line with the HDS, and wait more than 1 minute.

Test Procedure 

(Disconnected) Turbocharger bypass control solenoid valve connector (2P) female terminals

(Disconnected) PCM connector E (80P) - Refer to: PCM Connector for Inputs and Outputs (1.5L Engine) or PCM Connector for Inputs and Outputs (2.0L Engine) (2024 2025) female terminals

IG Mode

GHH652971Courtesy of HONDA, U.S.A., INC.
GHH652972Courtesy of HONDA, U.S.A., INC.

Normal Conditions

ABV open wire inspection 

OFF

There is less than 1 Ohm 

Results